Search results for "Emission computed tomography"

showing 10 items of 46 documents

Based on Compton Camera

2016

Compton Cameras have been proposed as an alternative to SPECT imaging with Gamma Camera, mainly due to factors such as the electronic collimation, which allows a bigger field of view and provides further information from the acquired events if compared to devices with mechanical collimation. By contrast, this involves a higher amount of data to be processed. In medical devices this leads to waiting times that are generally higher than desirable by the health-care professionals. In this work we have assessed the reconstruction of Compton images by making use of iterative and non-iterative techniques, and also evaluated its performances as a SPECT imaging technique.

Physicsmedicine.diagnostic_testbusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONField of view02 engineering and technologyIterative reconstructionSingle-photon emission computed tomography021001 nanoscience & nanotechnology01 natural scienceslaw.invention010309 opticslawSpect imaging0103 physical sciencesmedicineMedical imagingComputer visionArtificial intelligence0210 nano-technologyElectronic CollimationbusinessImage resolutionGamma camera2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)
researchProduct

Intraoperative Scintigraphy With Portable Gamma Camera for the Localization of Interaortocaval Paraganglioma

2021

A 15-year-old adolescent girl diagnosed of interaortocaval paraganglioma with a positive 123I-MIGB SPECT/CT and 1 unsuccessful prior surgery was operated on with the assistance of a handheld gamma camera. Once the lesion was located and removed, 2 images were taken, one of the surgical field (without 123I-MIGB uptake) and another of the tumor ex vivo (with high 123I-MIGB uptake), confirming that the lesion had been satisfactorily excised. This case highlights the use of a portable gamma camera as a useful tool to locate this rare tumor, with a SPECT/CT positive for 123I-MIGB and a difficult anatomical location suspected.

Prior SurgerySingle Photon Emission Computed Tomography Computed TomographyAdolescentmedicine.diagnostic_testbusiness.industryGeneral MedicineScintigraphymedicine.diseaselaw.inventionParagangliomaLesionRare tumorParagangliomalawmedicineHumansFemaleGamma CamerasRadiology Nuclear Medicine and imagingmedicine.symptomRadionuclide ImagingNuclear medicinebusinessGamma cameraClinical Nuclear Medicine
researchProduct

SPET/CT image co-registration in the abdomen with a simple and cost-effective tool

2002

Fusion of morphology and function has been shown to improve diagnostic accuracy in many clinical circumstances. Taking this into account, a number of instruments combining computed tomography (CT) with positron emission tomography (PET) or single-photon emission tomography (SPET) are appearing on the market. The aim of this study was to evaluate a simple and cost-effective approach to generate fusion images of similar quality. For the evaluation of the proposed approach, patients with neuroendocrine abdominal tumours with liver metastases were chosen, since the exact superimposition in the abdomen is more difficult than in other regions. Five hours following the injection of 110 MBq (111)In…

Quality ControlRadiography AbdominalRestraint Physicalmedicine.medical_specialtyImage qualityRadiographySingle-photon emission computed tomographyDigestive System NeoplasmsSensitivity and SpecificityAbdomenHumansMedicineRadiology Nuclear Medicine and imagingTomography Emission-Computed Single-PhotonImage fusionmedicine.diagnostic_testbusiness.industryLiver NeoplasmsSubtractionReproducibility of ResultsGeneral MedicineImage EnhancementNeuroendocrine TumorsPositron emission tomographySubtraction TechniqueTomographyRadiologyTomography X-Ray ComputedbusinessNuclear medicineEmission computed tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging
researchProduct

Active unilateral condylar hyperplasia : assessment of the usefulness of single photon emission computed tomography

2020

[Background] This study aims to evaluate whether the uptake difference by the condyles evaluated using single photon emission computed tomography (SPECT) examination is useful for predicting the activity of the feature and the advance of this pathology.

Single photon emission computed tomographyCondylar hyperplasiaMandibleSingle-photon emission computed tomographyTemporomandibular jointCondyleMedicineHumansClinical significanceProspective StudiesFacial asymmetryGeneral DentistryTomography Emission-Computed Single-PhotonHyperplasiamedicine.diagnostic_testbusiness.industryResearchMandibular CondyleScintigra-phyCraniometry:CIENCIAS MÉDICAS [UNESCO]ScintigraphyTemporomandibular jointmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASBone maturationSurgeryTomographyOral SurgeryNuclear medicinebusinessFacial symmetry
researchProduct

Three-Dimensional Surface Display in Blood Pool Gated SPECT

1994

In 14 patients (4 in good health and 10 with coronary heart disease) a blood pool gated single photon emission computed tomography (SPECT) was executed. The transaxial slices of the cardiac blood pool were reconstructed. A three-dimensional surface display was employed for the analysis of the tomographic data. A fixed distance, a fixed threshold (50%), and some different planes of view were employed. The test permitted visualiza tion of the ventricular and the atrial movements in all patients. The right ventricle was clearly seen in the right anterior oblique plane of view. The aortic beating was seen. In normal patients the left ventricle, clearly seen in left anterior oblique plane, shra…

Tomography Emission-Computed Single-Photonmedicine.diagnostic_testbusiness.industryBlood poolGated SPECTCoronary DiseaseGated Blood-Pool ImagingBlood volume030204 cardiovascular system & hematologySingle-photon emission computed tomographyCoronary heart disease03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureVentricleImage Processing Computer-AssistedHumansMedicineSurface geometry030212 general & internal medicineCardiology and Cardiovascular MedicinebusinessNuclear medicineArteryAngiology
researchProduct

Comparison of MRI and VQ-SPECT as a Screening Test for Patients With Suspected CTEPH: CHANGE-MRI Study Design and Rationale

2020

The diagnostic strategy for chronic thromboembolic pulmonary hypertension (CTEPH) is composed of two components required for a diagnosis of CTEPH: the presence of chronic pulmonary embolism and an elevated pulmonary artery pressure. The current guidelines require that ventilation–perfusion single-photon emission computed tomography (VQ-SPECT) is used for the first step diagnosis of chronic pulmonary embolism. However, VQ-SPECT exposes patients to ionizing radiation in a radiation sensitive population. The prospective, multicenter, comparative phase III diagnostic trial CTEPH diagnosis Europe - MRI (CHANGE-MRI, ClinicalTrials.gov identifier NCT02791282) aims to demonstrate whether functional…

VQ-SPECT0301 basic medicinelcsh:Diseases of the circulatory (Cardiovascular) systemmedicine.medical_specialtypulmonary embolismElevated pulmonary artery pressurePHCTEPHPopulationCardiovascular Medicine030204 cardiovascular system & hematologyMri ; Vq-spect ; Cteph ; Ph ; Pulmonary Embolism ; Diagnostic Strategydiagnostic strategyStudy Protocol03 medical and health sciences0302 clinical medicinemedicine.arteryPulmonary angiographyMedicineeducationeducation.field_of_studymedicine.diagnostic_testbusiness.industryDiagnostic TrialGold standard (test)medicine.disease3. Good healthPulmonary embolism030104 developmental biologylcsh:RC666-701Pulmonary arteryRadiologyCardiology and Cardiovascular MedicinebusinessEmission computed tomographyMRIFrontiers in Cardiovascular Medicine
researchProduct

Left-Ventricle Segmentation of SPECT Images of Rats

2015

Single-photon emission computed tomography (SPECT) imaging of the heart is helpful to quantify the left-ventricular ejection fraction and study myocardial perfusion scans. However, these evaluations require a 3-D segmentation of the left-ventricular wall on each phase of the cardiac cycle. This paper presents a fast and interactive graph cut method for 3-D segmentation of the left ventricle (LV) of rats in SPECT images. The method is carried out in three steps. First, 3-D sampling of the LV cavity is made in a spherical-cylindrical coordinate system. Then, a graph-cut-based energy minimization procedure provides delineation of the myocardium centerline surface. From there, it is possible to…

[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingHeart VentriclesBiomedical Engineering030204 cardiovascular system & hematologySingle-photon emission computed tomography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineImaging Three-DimensionalCutmedicineAnimalsComputer visionSegmentationLongitudinal Studies[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/ImagingComputingMilieux_MISCELLANEOUSMathematicsTomography Emission-Computed Single-Photonmedicine.diagnostic_testCardiac cycleOrientation (computer vision)business.industryImage segmentationRatsTomographyArtificial intelligencebusinessEmission computed tomography
researchProduct

Optimal recovery of a radiating source with multiple frequencies along one line

2020

We study an inverse problem where an unknown radiating source is observed with collimated detectors along a single line and the medium has a known attenuation. The research is motivated by applications in SPECT and beam hardening. If measurements are carried out with frequencies ranging in an open set, we show that the source density is uniquely determined by these measurements up to averaging over levelsets of the integrated attenuation. This leads to a generalized Laplace transform. We also discuss some numerical approaches and demonstrate the results with several examples.

attenuated Radon transformMultispectralRAYUniqueness theorem01 natural sciencesinversio-ongelmat44A10 (Primary) 65R32 44A60 46N40 65Z05 (Secondary)030218 nuclear medicine & medical imaging0302 clinical medicine111 MathematicsDiscrete Mathematics and CombinatoricstietokonetomografiaPharmacology (medical)INVERSIONnuclear medicineBeam hardeningPhysicsLaplace transformDetectorNumerical Analysis (math.NA)Inverse problemuniqueness theoremFunctional Analysis (math.FA)Mathematics - Functional AnalysisMultiplicative system theoremkuvantaminensovellettu matematiikkaModeling and SimulationSPECTLine (geometry)numeerinen analyysipositroniemissiotomografiaemission computed tomographyAttenuated Radon transformEmission computed tomographyControl and OptimizationLaplace transformmultispectralOpen setCollimated light03 medical and health sciencesnuclear medicine.multiplicative system theoremFOS: Mathematicsinverse source problemMathematics - Numerical Analysis0101 mathematicsAttenuation010102 general mathematicsInverse source problemRangingComputational physicsTENSOR TOMOGRAPHYPETbeam hardeningNuclear MedicineAnalysis
researchProduct

Novel Radiolabeled Bisphosphonates for PET Diagnosis and Endoradiotherapy of Bone Metastases.

2017

Bone metastases, often a consequence of breast, prostate, and lung carcinomas, are characterized by an increased bone turnover, which can be visualized by positron emission tomography (PET), as well as single-photon emission computed tomography (SPECT). Bisphosphonate complexes of 99mTc are predominantly used as SPECT tracers. In contrast to SPECT, PET offers a higher spatial resolution and, owing to the 68Ge/68Ga generator, an analog to the established 99mTc generator exists. Complexation of Ga(III) requires the use of chelators. Therefore, DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid), NOTA (1,4,7-triazacyclododecane-1,4,7-triacetic acid), and their derivatives, are ofte…

diagnosismedicine.medical_treatmentPharmaceutical ScienceReview030218 nuclear medicine & medical imagingBone remodeling03 medical and health scienceschemistry.chemical_compound0302 clinical medicinebone metastasesDrug DiscoverymedicineDOTAbisphosphonatestherapymedicine.diagnostic_testbusiness.industryBisphosphonate177Lu68GachemistryPositron emission tomography030220 oncology & carcinogenesisMolecular MedicineNuclear medicinebusinessEmission computed tomographyPharmaceuticals (Basel, Switzerland)
researchProduct

Bone targeting compounds for radiotherapy and imaging: *Me(III)-DOTA conjugates of bisphosphonic acid, pamidronic acid and zoledronic acid

2016

Background Bisphosphonates have a high adsorption on calcified tissues and are commonly used in the treatment of bone disorder diseases. Conjugates of bisphosphonates with macrocyclic chelators open new possibilities in bone targeted radionuclide imaging and therapy. Subsequent to positron emission tomography (PET) examinations utilizing 68Ga-labelled analogues, endoradiotheraphy with 177Lu-labelled macrocyclic bisphosphonates may have a great potential in the treatment of painful skeletal metastases. Methods Based on the established pharmaceuticals pamidronate and zoledronate two new DOTA-α-OH-bisphosphonates, DOTAPAM and DOTAZOL(MM1.MZ) were successfully synthesized. The ligands were labe…

lcsh:Medical physics. Medical radiology. Nuclear medicineBiodistributionMaterials sciencelcsh:R895-920Hydroxy bisphosphonatesSingle-photon emission computed tomography01 natural sciences030218 nuclear medicine & medical imagingAnalytical Chemistry03 medical and health scienceschemistry.chemical_compound0302 clinical medicinePharmacokineticsmedicineDOTAPharmacology (medical)Radiology Nuclear Medicine and imagingZoledronic acidPharmacologymedicine.diagnostic_test010405 organic chemistrybusiness.industryResearchBone metastaseslcsh:RM1-950Pamidronic acid177LuTheranostics68Ga0104 chemical sciencesZoledronic acidPETlcsh:Therapeutics. PharmacologyDOTAchemistryPositron emission tomographyNuclear medicinebusinessEx vivomedicine.drugEJNMMI Radiopharmacy and Chemistry
researchProduct