Search results for "Emt"
showing 10 items of 413 documents
Museo Archeologico Regionale di Gela. Sequestri di monete da Gela e il suo territorio
2004
The exhibition in Gela of the finds seized by the law enforcement between 1970 and 2000 in the surrounding area of the ancient colony is an opportunity for the analysis of the 200 coins, part of the finds. Probably found in the area of Gela, they integrate our knowledge of numismatic discoveries from the area of the ancient city and from the chora. Of particular interest are two homogeneous groups that seem likely to belong to two hoards, datable, respectively, to the 4th century AD and in the 9th century AD
Mantojuma masas reālā sadale
2017
Bakalaura darba temats ir “Mantojuma masas reālā sadale”. Tas ir nozīmīgs mantojuma tiesību aspekts, ar ko jāsaskaras katram mantiniekam, ja mantojums ir piekritis vienlaicīgi vairākām personām. Darba mērķis ir izpētīt līdzmantinieku savstarpējās attiecības, tiesības prasīt mantojuma dalīšanu, mantojuma kopvaldījuma izbeigšanu, dalāmās mantas noteikšanu, iepriekšēji saņemtā pievienojumu un mantojuma masas reālo sadali. Mērķi tiks sasniegti, analizējot normatīvos aktus, salīdzinot juridiskajā literatūrā paustās atziņas un pētot mantojuma tiesību institūta vēsturisko attīstību, kā rezultātā tiks identificēti problēmjautājumi, kas šobrīd skar līdzmantinieku savstarpējās attiecības un mantojuma…
Mesure de l'effet Kerr d'ordre élevé des constituants de l'air
2009
Talk given by V. Loriot
Ārpusķermeņa apaugļošanā iegūta cilvēka ieņemteņa tiesiskais stāvoklis.
2018
Bakalaura darba mērķis ir noskaidrot ārpusķermeņa apaugļošanā iegūta cilvēka ieņemteņa tiesisko stāvokli periodā no atsevišķu sievišķo un vīrišķo dzimumšūnu sapludināšanas līdz cilvēka ieņemteņa ievadei sievietes dzimumorgānos. Lai sasniegtu darba mērķi, pētījuma gaitā ir veikta padziļināta specializētās teorētiskās literatūras un tiesību avotu izpēte, konstatētas būtiskas saistošo zinātņu nozaru terminoloģijas nianses, kā arī izanalizēti pieejamie teorijas un prakses materiāli. Pētījuma rezultātā noskaidrots, ka ārpusķermeņa apaugļošanā iegūtam cilvēka ieņemtenim ir liettiesisks stāvoklis, kas izbeidzas ar tā ievadi sievietes dzimumorgānos. Kamēr cilvēka ieņemtenim ir liettiesisks stāvokli…
Non-linear interactions of femtosecond laser pulses with graphene : photo-oxidation, imaging and photodynamics
2017
This thesis presents a study focused on interactions of femtosecond laser pulses with graphene, a one atom thick carbon membrane. Graphene, which exhibits exceptional electronic and optoelectronic properties, could provide considerable advantage over current silicon-based electronics. Graphene alone, being semi-metal, is not sufficient for electronic applications, but requires modification. For this, a set of methods for modifying and measuring the properties of graphene was developed. With the perspective of making graphene a suitable component for electronics, optoelectronics or photonics, ultrashort laser pulses were used for drawing patterns on graphene. The procedure modifies graphene …
Electrical measurements of femtosecond laser treated graphene
2017
Tutkielman pääasiallinen tavoite oli valmistaa sähköisiin mittauksiin sopivia grafeenilaitteita ja tutkia femtosekuntilaserkäsittelyn vaikutusta grafeenin sähköisiin ominaisuuksiin. Tutkielmassa käsitellään grafeenin valmistamista kemiallisella kaasufaasipinnoituksella, laitegeometrian määrittelyä ja käsittelemättömän, sekä femtosekuntilaserilla käsitellyn grafeenin sähköisiä mittauksia. Grafeenin synteesin alustana käytettiin kupariohutkalvoja ja pääasiallisena lähtöaineena oli etanoli tai metaani. Metaanin käyttö grafeenin synteesissä johti paremmin toistettaviin tuloksiin. Lisäksi havaittiin, että synteesissä käytetyn uunin latausjärjestelmän teräksinen osa lisäsi kupariohutkalvon reikii…
Evaluation of a new nomogram for Ferrara ring segment implantation in keratoconus
2021
AIM: To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data. METHODS: This prospective longitudinal non-comparative clinical trial evaluated 88 eyes of 88 patients (age 18-62y) with keratoconus diagnosis from two Spanish centers. Ferrara ring segment (AJL Ophthalmic) implantation was performed in all cases, using the mechanical procedure in 25 eyes (28.4%) and a femtosecond laser-assisted procedure in 63 eyes (71.6%). The ring segments implanted in each case were selected using a new optimized nomogram that considered variables such as anterior corneal asph…
MAGNETIC RESONANCE IMAGING–GUIDED FOCUSED ULTRASOUND THALAMOTOMY IN PATIENT WITH TREMOR COMBINED WITH PARKINSONISM: RETREATMENT AFTER BENEFIT DECAY
2019
Background In recent years, transcranial Magnetic Resonance-guided Focused UltraSounds (tcMRgFUS) treatments for functional neurological disorders are giving a new thrust to the field of therapeutic brain lesioning. This technique has been proven safe and effective in selected patients. Here we present the case of a patient affected by tremor combined with parkinsonism who underwent a second tcMRgFUS thalamotomy because of relapsing tremor after a few months from the first tcMRgFUS treatment. Materials and Methods A 72-year-old, right-handed man, who came to our observation because of a disabling tremor affecting mainly his upper right limb and refusing any invasive surgical procedure. His …
VisuMax®femtosecond laser for corneal refractive surgery
2008
Femtosecond lasers are increasingly present in ophthalmologic surgical theaters for a variety of reasons. These include faster and better visual outcomes, increased accuracy and predictability for corneal flap thickness in laser in situ keratomileusis procedures. Recent applications of modern femtosecond lasers have broadened the range of uses: keratoplasty, intrastromal segment insertion and even glaucoma and presbyopia surgery. This device profile provides an overview of the advantages of femtosecond lasers in ophthalmic surgery, paying special attention to the new VisuMax® femtosecond laser from Zeiss/Meditec.
Femtosecond‑LASIK outcomes using the VisuMax®‑MEL® 80 platform for hyperopia and hyperopic astigmatism refractive surgery
2021
The present study evaluated the efficacy, the safety and the predictability of the Femtosecond laser-assisted in situ keratomileusis (Femto-LASIK) procedure for hyperopia and hyperopic astigmatism. We retrospectively analyzed the postoperative 12-month evolution of 593 eyes with hyperopia and hyperopic astigmatism that underwent Femto-LASIK treatment. The procedure was predictable and effective. No eye lost 2 lines of corrected distance visual acuity (CDVA), demonstrating a safety profile of the procedure. Nine percent of the eyes gained at least one line of CDVA. The accuracy of the spherical equivalent after 12 months was 74% within ±1.0 diopter (D) of emmetropia. The refractive outcomes …