Search results for "Endosonography"

showing 10 items of 30 documents

Correlation of endoanal sonography with cross-sectional anatomy of the anal sphincter

1999

Abstract Background: Anal endosonography has become an important imaging method in the diagnosis of anorectal disorders. However, little information exists as to whether anal endosonography reliably defines pelvic floor structures. The aim of this study was to correlate endoanal sonography with cross-sectional anatomy and histology. Methods: Endosonographic tomograms were obtained from 9 human cadavers before fixation and cross-sectioning at identical levels. Muscular layers were defined by visual inspection, histology, immunohistology, and morphometry using three-dimensional sphincter reconstructions. Results: Endosonography visualized only two muscular layers, whereas anatomic sections al…

MaleAnal CanalRectumSensitivity and SpecificityEndosonographyInternal anal sphincterReference ValuesCadavermedicineHumansRadiology Nuclear Medicine and imagingAgedAged 80 and overPelvic floorAnatomy Cross-Sectionalmedicine.diagnostic_testbusiness.industryUrethral sphincterRectumGastroenterologyAnatomyAnal canalEndoscopymedicine.anatomical_structureSphincterFemalebusinessGastrointestinal Endoscopy
researchProduct

Pure cystic groove pancreatitis: endosonographic appearance.

2019

Malemedicine.medical_specialtybusiness.industryGastroenterologyContrast MediaMagnetic Resonance ImagingEndosonographyYoung AdultText miningPancreatitis ChronicMedicineHumansRadiologyGroove pancreatitisPancreatic CystbusinessTomography X-Ray ComputedBiomarkersEndoscopy
researchProduct

German Survey on EUS-Guided Diagnosis and Management of Gastrointestinal Stromal Tumors (GISTs) - Evidence or "Gut-Feeling"?

2015

To examine practice patterns of endosonographers in diagnosing and managing gastrointestinal stromal tumors (GISTs) in Germany.A modified published survey (Ha et al., Gastrointest Endosc 2009) was sent to endosonographic ultrasound (EUS) customers in Germany. The survey was also publicized on the homepage of an EUS interest group. To avoid duplicate opinions, participants were asked to return one survey per institution.142 centers of roughly 850 German EUS centers responded. 25 % were from University hospitals and 74 % from community hospitals. 61 % performed 2 EUS scans for suspected subepithelial lesions/week. Although 97 % of respondents believed that tissue acquisition with CD117 immuno…

Endoscopic ultrasoundImage-Guided Biopsymedicine.medical_specialtyGastrointestinal Stromal Tumorsmedia_common.quotation_subjectBiopsy Fine-NeedleSensitivity and SpecificityEndosonographySurveys and QuestionnairesBiopsyMedicineHumansRadiology Nuclear Medicine and imagingGastrointestinal stromal tumors (GISTs)Practice Patterns Physicians'neoplasmsUltrasonography Interventionalmedia_commonGastrointestinal Neoplasmsmedicine.diagnostic_testGiSTbiologybusiness.industryCD117Stomachmedicine.diseasedigestive system diseasesEndoscopyFine-needle aspirationFeelingbiology.proteinRadiologybusinessUltraschall in der Medizin (Stuttgart, Germany : 1980)
researchProduct

Diagnostic performance of endoscopic ultrasound through‐the‐needle microforceps biopsy of pancreatic cystic lesions: Systematic review with meta‐anal…

2020

Objectives Endoscopic ultrasound through-the-needle biopsy (EUS-TTNB) is a useful tool for differential diagnosis among pancreatic cystic lesions (PCLs). Cystic fluid cytology (CFC) is recommended by guidelines, but its diagnostic accuracy is about 50%. The aim of this meta-analysis is to assess the clinical impact of EUS-TTNB in terms of technical success (TS), histological accuracy (HA) and diagnostic yield (DY). Methods Original studies in English language on EUS-TTNB were searched in MEDLINE and EMBASE until October 2019. Diagnostic accuracy of EUS-TTNB for identification of mucinous PCLs was calculated using individual diagnostic data of patients who underwent CFC and surgery. Results …

Endoscopic ultrasoundmedicine.medical_specialtyserous cystadenomaEndosonographyhistologyCystic lesion03 medical and health sciences0302 clinical medicineBiopsymedicineHumansRadiology Nuclear Medicine and imagingCystAdverse effectEndoscopic Ultrasound-Guided Fine Needle AspirationPancreasIntraductal papillary mucinous neoplasmmedicine.diagnostic_testbusiness.industryIPMNintraductal papillary mucinous neoplasmGastroenterologymedicine.diseasedigestive system diseasesConfidence intervalPancreatic NeoplasmsFNA030220 oncology & carcinogenesisMeta-analysis030211 gastroenterology & hepatologyRadiologyPancreatic CystDifferential diagnosisbusinessDigestive Endoscopy
researchProduct

Endo-neuro-sonography: principles and 3-D technique

1997

To evaluate the usefulness of transendoscopic sonography we studied two new sono probes 6 F in diameter in 17 fresh specimens. We saw precise imaging of well-known anatomical structures and also gained an additional dimension in endoscopy, as the sono adds to the endo-view a transverse scan like a mini-CT at the tip of the probe. We also experienced the navigation characteristic of this imaging technique, both in real time and on line. Some 3-D reconstructions of the ventricular system were examined. The equipment has been used in clinical practice and must now be adapted for neurosurgery.

Adultmedicine.medical_specialtyNeuronavigationmedicine.diagnostic_testbusiness.industryAnatomical structuresBrainEndoscopic anatomyGeneral MedicineEchoencephalographyEndosonographySurgeryEndoscopyClinical PracticeChild PreschoolPediatrics Perinatology and Child HealthImage Processing Computer-AssistedHumansMedicineNeurology (clinical)Imaging techniqueTomography X-Ray ComputedbusinessBiomedical engineeringChild's Nervous System
researchProduct

Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis

2017

PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…

MaleOrgans at Riskmedicine.medical_specialtyCoefficient of variationmedicine.medical_treatmentBrachytherapyBrachytherapyRectumRadiation DosageStandard deviationEndosonography030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineHumansMedicineRadiology Nuclear Medicine and imagingProspective StudiesObserver VariationContouringProstate cancerbusiness.industryEquivalent doseRadiotherapy Planning Computer-AssistedRectumProstatic NeoplasmsRadiotherapy DosageOrgan Sizemedicine.diseaseHigh-Dose Rate Brachytherapymedicine.anatomical_structureOncologyContouringHigh-dose-rate brachytherapy030220 oncology & carcinogenesisRadiologyInterobserver variabilitybusinessNuclear medicineBrachytherapy
researchProduct

Colour Doppler-guided haemorrhoidal artery ligation: an adjunct in identification of haemorrhoidal vessels.

2012

Not available (case report)

HemorrhoidectomyMalemedicine.medical_specialtyHemorrhoidsEndosonographyMedicineHumansMinimally Invasive Surgical ProceduresUltrasonography Doppler ColorLigationbusiness.industrySuture TechniquesGastroenterologyRectumColorectal surgeryAdjunctArtery ligationSettore MED/18 - Chirurgia GeneraleTreatment OutcomeColour dopplerSurgeryRadiologyColour doppler-guided haemorrhoidal artery ligation. Haemorrhoidal artery ligation. haemorrhoidectomy. Transanal haemorrhoidal dearterializationbusinessAbdominal surgeryFollow-Up StudiesTechniques in coloproctology
researchProduct

The ideal lateral internal sphincterotomy: clinical and endosonographic evaluation following open and closed internal anal sphincterotomy

2009

To evaluate the relationship between extent of internal sphincter division following open and closed sphincterotomy, as assessed by anal endosonography, with fissure persistence/recurrence and faecal incontinence.A total of 140 consecutive patients undergoing lateral internal sphincterotomy (LIS) for idiopathic chronic anal fissure were prospectively studied. Preoperative clinical assessment was performed together with a postoperative clinical and endosonographic examination. Three zones of the internal sphincter, identifiable by endosonography, were used to describe the uppermost extent of LIS. Primary end-points were fissure persistence/recurrence and faecal incontinence.A total of 140 pa…

AdultMalemedicine.medical_specialtyPercutaneousInternal Anal Sphincterotomymedicine.medical_treatmentChronic anal fissureAnal CanalEndosonographyPersistence (computer science)Sphincterotomy EndoscopicRecurrencemedicineHumansProspective StudiesProspective cohort studyAnal fissurebusiness.industryUrethral sphincterGastroenterologyMiddle Agedmedicine.diseaseSurgeryFemaleFissure in AnobusinessLateral internal sphincterotomyFecal IncontinenceFollow-Up StudiesColorectal Disease
researchProduct

Direct image-guided retroperitoneal approach and treatment of the pancreas by using natural orifice transluminal endoscopic surgery after EUS sugar-a…

2021

Endoscopic ultrasoundNatural Orifice Endoscopic Surgerymedicine.medical_specialtymedicine.diagnostic_testbusiness.industryRadiofrequency ablationGastroenterologylaw.inventionEndosonographymedicine.anatomical_structureSurgery Computer-AssistedlawCatheter AblationMedicineHumansRadiology Nuclear Medicine and imagingRadiologyRetroperitoneal SpacebusinessPancreasSugarsPancreasRetroperitoneal approachGastrointestinal endoscopy
researchProduct

Prognostic Heterogeneity of Endosonographic T3 Rectal Cancer

2009

PURPOSE: This study aimed to assess the prognostic implications of uT3 rectal carcinomas according to the tumor thickness and to analyze the correlation between this ultrasound-based parameter and other prognostic factors. METHODS: Seventy-four patients with uT3(pM0) rectal tumors underwent primary surgery from 1996 to 2003. Preoperative endorectal ultrasound was used to assess uN stage, maximum tumor perimeter, and maximum tumor thickness. An ultrasound maximum tumor thickness cutoff point for local recurrence subdividing T3 tumors into uT3a and uT3b was established. RESULTS: Median follow-up was 41 months (range, 24-59). The 5-year actuarial local and overall recurrence rates were 9.82 pe…

Malemedicine.medical_specialtyColorectal cancermedicine.medical_treatmentKaplan-Meier EstimateEndosonographyPerimeterHumansMedicineNeoplasm InvasivenessStage (cooking)Neoadjuvant therapyAgedRectal Neoplasmsbusiness.industryHazard ratioUltrasoundGastroenterologyCancerGeneral MedicineMiddle AgedPrognosismedicine.diseaseConfidence intervalFemaleRadiologyNeoplasm Recurrence LocalbusinessDiseases of the Colon & Rectum
researchProduct