Search results for "Endosseous"
showing 10 items of 119 documents
Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.
2015
Objective The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Material and methods Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectros…
In vitro comparison of primary stability of two implant designs in D3 bone
2016
Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…
Short implants (8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: A meta-analysis of RCT`s in h…
2019
Background One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high survival rate of implants placed next to sinus elevation, this technique presents complications that can be avoided by placing short implants, an option that also presents high survival rates. For this reason, the aim of this study is to compare the survival rate, marginal bone loss and complications associated with short implants (<8 mm) versus longer implants (≥8mm) placed with lateral sinus floor elevation in posterior atrophic maxillae. Material and Methods A literature search was conducted …
Maintenance of Class III Trifurcated Molars Versus Implant Placement in Regenerated Extraction Sockets: Long-Term Results of 2 Cases
2011
Studies to date have reached differing conclusions regarding the long-term prognosis of teeth with class III furcation involvement. Replacement of such teeth with implants could be an alternative. This report compares the treatment outcomes of 2 cases with similar disease progression: 1 treated by implant therapy and 1 maintained with nonsurgical periodontal treatment. Two patients with advanced chronic periodontitis and class III furcation involvement of all molars were treated. Case 1 received a conservative periodontal and antibiotic treatment, followed by 15 years of maintenance. In case 2, the molars were extracted and replaced with implants, and the implants were observed for 7 years.…
Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study
2018
GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…
Immediate post-extraction implants placed in acute periapical infected sites with immediate prosthetic provisionalization : a 1-year prospective coho…
2020
Background Few studies have reported the outcomes of immediate placement at infected post-extraction sites. The aim of this study was to compare clinical and radiological outcomes of immediately placed implants with immediate prosthetic provisionalization in sockets with or without acute periapical pathology. Material and Methods A total of 100 patients with immediately placed implants with immediate provisionalization and 1- year of follow up were included (50 patients with acute periapical pathology and a control group of 50 patients without acute periapical pathology). Clinical parameters (bleeding on probing, buccal keratinized mucosa width, clinical recession, and probing depth) and ra…
Placement of endosseous implants in patients with oral epidermolysis bullosa.
2000
Abstract Objective: To evaluate the feasibility of placing endosseous implants in patients with recessive dystrophic epidermolysis bullosa. This article reports on 4 patients subjected to follow-up. Study Design: Implants were placed in 4 cases. All patients have marked oral involvement, with devastating alterations in the soft and hard tissues in all cases. Results: A total of 15 implants (7 maxillary, 8 mandibular) were placed. All implants integrated successfully and have been restored. The average follow-up from implant placement was 2.5 years (range, 1-4). Conclusions: Our preliminary findings suggest that endosseous implants can be successfully placed and can provide support for prost…
Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…
2015
BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …
Rehabilitation of the severely atrophied dentoalveolar ridge in the aesthetic region with corticocancellous grafts from the iliac crest and dental im…
2016
Background The aim of this study was to assess changes in bone volume after block bone augmentation and placement of dental implants and further evaluate the aesthetic outcome of the treatment. Material and Methods 9 Patients with atrophied anterior maxilla were included in this study. They received total of 21 implants. Dimensions of the alveolar ridge were measured from cone-beam computed tomography x-rays. The bone level at the implant sites was analysed from intraoral x-rays and the aesthetic outcome was assessed from clinical photographs using a pink aesthetic score (PES) scaling. Results The mean gained horizontal bone width at the marginal crest and 5 mm apically was accordingly 2.7m…
Relation between bone quality values from ultrasound transmission velocity and implant stability parameters--an ex vivo study.
2011
Aim The objective of this study was to determine the relationship between bone qualities measured by ultrasound transmission velocity (UTV) and primary implant stability parameters measured by radiofrequency analysis (RFA) and push-out test (POT) in an ex-vivo model. Materials and methods Three blocks of fresh porcine bone samples were obtained from different anatomic regions, correlating to cortical, mixed and cancellous bone. Mechanical bone qualities of these samples were measured using UTV (expressed in m/s) prior to implantation. Three similar implants (4.1 × 11 mm, AstraTech OS) were inserted into each of the procured bone blocks. The evaluation of implant-bone interface stability was…