Search results for "Endovascular procedure"
showing 10 items of 131 documents
A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be cl…
2012
Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …
Outpatient endovascular aortic aneurysm repair: Experience in 100 consecutive patients
2013
OBJECTIVES:: To present the safety, feasibility, costs, and patient satisfaction of outpatient endovascular aneurysm repair (EVAR). BACKGROUND:: Our experience in more than 1000 patients indicated that in technically uncomplicated EVAR procedures, the only need for hospitalization was for access vessel complications (bleeding or occlusion) requiring secondary procedures. These complications could always be identified within the first 3 hours after EVAR. METHODS:: Two-center retrospective analysis of prospectively gathered data on 100 consecutive elective outpatient EVAR cases (Outpt EVAR). Inclusion criteria for Outpt EVAR were as follows: asymptomatic clinical state, informed consent, trav…
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …
MRI patient selection for endovascular thrombectomy in acute ischemic stroke: correlation between pretreatment diffusion weighted imaging and outcome…
2018
Introduction: Eligibility for endovascular treatment (EVT) in patients with acute ischemic stroke (AIS) depends, amongst other factors, on CT- or MR-based scores. The aim of this study was to investigate the role of Alberta Stroke Program Early CT score based on diffusion weighted imaging (MR-ASPECT) in the assessment of brain damage pre-EVT, patient selection for EVT and outcome. Materials and methods: We included in this study patients with National Institute of Health stroke score (NIHSS) at admission ≥ 8, MR-ASPECT ≥ 5 and anterior AIS, who were treated with EVT in our hospital. All patients were clinically evaluated at admission, post-EVT, discharge and at 3-month follow-up. We used MR…
Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…
2016
Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…
A Multicenter Experience With a New Fenestrated-Branched Device for Endovascular Repair of Thoracoabdominal Aortic Aneurysms.
2018
To investigate the outcomes of patients who were treated for thoracoabdominal aortic aneurysms (TAAAs) using custom-made fenestrated-branched stent-grafts.A consecutive series of 108 patients (mean age 73.5 years; 73 men) with TAAA were treated with E-xtra Design Engineering customized fenestrated-branched stent-grafts between November 2011 and January 2017. Data on baseline characteristics, procedures, and clinical follow-up were collected from 6 regional European surgical centers for retrospective analysis of endoleaks, reinterventions, and target vessel patency. The median aneurysm diameter was 6.75 cm (range 5.5-13). The distribution of the TAAA according to the modified Crawford classi…
Popliteal Artery Aneurysm Repair in the Endovascular Era: Fourteen-Years Single Center Experience
2015
Abstract To compare outcomes of popliteal artery aneurysm (PAA) repair by endovascular treatment, great saphenous vein (GSV) bypass, and prosthetic bypass. Single center retrospective analysis of patients presenting PAA from 2000 to 2013. Patients were divided into endovascular treatment (group A); GSV bypass (group B); and prosthetic graft bypass (group C). Outcomes were technical success, perioperative mortality, and morbidity. Survival, primary and secondary patency, and freedom from reintervention rate were estimated. Differences in ankle-brachial index (ABI), in-hospital length of stay (InH-Los), red blood cell (RBC) transfusion, and limb loss were reported. Mean follow-up was 49 (medi…
Repair of TEVAR-Associated Type A Dissection in the Elderly Is Possible With Reasonable Morbidity and Mortality.
2018
Background: Type A aortic dissection (AAD) is a devastating complication of thoracic endovascular repair (TEVAR). In elderly patients, surgery for AAD carries considerable morbidity and mortality. Repair of AAD after previous TEVAR is an even greater challenge as it usually requires the arch to be addressed and a preexisting stent graft to be included into the aortic repair. Methods: A case series of 5 elderly patients who presented with acute AAD after previous TEVAR was reviewed. In 4 cases, there was retrograde AAD with involvement of the arch and stent graft. In 1 patient, intraoperative inspection showed no involvement of the arch. Three underwent ascending and subtotal arch replacemen…
Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.
2013
To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3.From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 70±8 years, range 56-87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endografts were sized 1 …
Treating iliac aneurysm using the Nellix Endovascular Sac Sealing System.
2016
As endovascular treatment of abdominal aortic aneurysms has become established, there has been growing focus on treatment of the aneurysmal iliac artery. Isolated, large iliac aneurysms >30 mm pose a risk of rupture, but, in addition, 20% to 30% of abdominal aortic aneurysms are associated with iliac aneurysmal dilatation, which can compromise long-term outcomes. Endovascular solutions are evolving and until recently have utilized standard stent graft technology. The endovascular aortic sealing system was introduced as a new, effective method for the treatment of infrarenal aortic aneurysms. In this article, we present our recent extended use of the Nellix system, with or without a combinat…