Search results for "Energy engineering"
showing 10 items of 1099 documents
LNG cold energy use in agro-food industry: A case study in Sicily
2011
Abstract It is known how the complete gasification of liquefied natural gas (LNG) can return about 230 kWh/t of energy. Nevertheless out of fifty-one gasification plants in the world, only thirty-one of them are equipped with systems for the partial recovery of the available energy. At the moment most of these plants mainly produce electric energy; however the employment of the cold energy results very interesting, in fact, it can be recovered for agro-food transformation and conservation as well as for some loops in the cold chain. Cold energy at low temperatures requires high amounts of mechanical energy and it unavoidably increases as the required temperature diminishes. Cold energy reco…
On Thermoeconomic Diagnosis of a Fouled Direct Expansion Coil: Effects of Induced Malfunctions on Quantitative Performance of the Diagnostic Technique
2017
Thermoeconomic diagnosis represents a promising technique for the detection of common faults in refrigeration systems, which are responsible of degradation in their energetic performance. Recently, the authors have carried out a sensitivity analysis of the performance of this method to the thermodynamic conditions of inlet air and to the geometry of the direct expansion coil, in case of degradation induced by evaporator fouling. The analysis showed that the method is able to detect this fault, but sometimes its quantitative assessments are not satisfactory. In order to understand more in-depth the origin of such results and identify margins for refinement of the technique, this paper is aim…
Lightning-current distribution in MV grids interconnected earthing systems
2017
The paper presents first investigations results on the effects of lightning stroke on medium voltage (MV) installations' earthing systems, connected together with the metal shields of the MV distribution grid cables. The study enables to evaluate the distribution of the lightning current among interconnected earth electrodes in order to assess if the interconnection, usually done for reducing earth potential rise during an earth fault, can give place to dangerous situations far from the installation hit by the lightning stroke. Two case studies of direct lightning stroke are presented and discussed: two interconnected MV substations of the MV grid; a high voltage/medium voltage (HV/MV) stat…
An experimental study on relationship between LED lamp characteristics and non image-forming
2017
The general aim of the experimental study, presented in this paper, was that to investigate the relationship between the characteristics of five different types of LED (Light Emitting Diode) lamps, which are nowadays those allowing the highest energy consumption reduction, and the humans non image-forming (NIF) reactions.
Active load sharing technique for on-line efficiency optimization in DC microgrids
2017
Recently, DC power distribution is gaining more and more importance over its AC counterpart achieving increased efficiency, greater flexibility, reduced volumes and capital cost. In this paper, a 24-120-325V two-level DC distribution system for home appliances, each including three parallel DC-DC converters, is modeled. An active load sharing technique is proposed for the on-line optimization of the global efficiency of the DC distribution network. The algorithm aims at the instantaneous efficiency optimization of the whole DC network, based on the on-line load current sampling. A Look Up Table, is created to store the real efficiencies of the converters taking into account components toler…
Optimizing droop coefficients for minimum cost operation of islanded micro-grids
2017
This paper shows how minimum cost energy management can be carried out for islanded micro-grids considering an expanded state that also includes the system's frequency. Each of the configurations outputted by the energy management system at each hour are indeed technically sound and coherent from the point of view of generation-consumption balancing by exploiting a frequency dependent load flow algorithm. A Glow-worm Swarm Optimization (GSO) algorithm carried out in a 24 hour time frame provides optimized results. A test has been carried out for a residential PV-Storage-Microturbine islanded micro-grid to show the feasibility as well as the efficiency of the proposed approach and results ar…
Smart district energy optimization of flexible energy units for the integration of local energy storage
2017
Several changes are involving electrical power systems, especially distribution networks. For this reason, the actors in charge of managing and operating reliably these grids are facing many technical issues regarding demand and supply balancing, Renewable Energy Sources and Electric Vehicles integration, peak load shaving, etc. In this context, many energy actions have been implemented for providing services to the power system managers by means of prosumers' demand and/or supply flexibility. This study reports the development of a centralized energy management solution for smart grids equipped with local storage devices, RES, consumers and other energy facilities in a district context. Th…
Technical and Economic Aspects of Photovoltaic Conversion of Southern Poland
2014
Abstract The article presents the results of a 13-year tests and analysis of performance and energy and electrical charge yield for typical photovoltaic modules made of different absorbers. Modules were installed on the south wall of Opole University building (at kard. B. Kominka Street). Registered in this period (2001-2013) values energy and charge of tested modules are presented in reference to 1 Wp their nominal power and to 1 m2 of PV modules. Their annual and monthly distributions, with particular emphasis on the seasonal changes of its parameters and phenomena of aging and degradation of the PV modules structure were shown. In the final part of the article was presented an economic a…
On the hazardous situations due to the presence of HV/MV substations in urban areas
2017
The paper focuses on the hazardous situations that can rise in urban areas in case of earth fault inside a High Voltage/Medium Voltage station. IEEE and IEC/EN Standards and technical documents are examined and discussed, in order to propose some practical guidelines for a safe integration of such installations in contexts characterized by the presence of low voltage systems and not trained persons.
Heavy metal remediation technologies in Latvia: possible applications and preliminary case study results / Technologie remediacji obszarów zanieczysz…
2012
Abstract Environmental contamination with heavy metals as a result of anthropogenic activities is not a recent phenomenon. Contaminated sites with heavy metals can be found in functioning as well as abandoned industrial (brownfield) territories, landfills, residential areas with historical contamination, road sides and rarely in polluted sites by natural activities. Pollution data on its amount and concentrations is known from historical studies and monitoring nowadays, but it should be periodically updated for the use of territorial planning or in case of a change of the land use. A special attention should be paid to heavy metal contamination, because in many cases this contamination is m…