Search results for "Equipment Design"

showing 10 items of 409 documents

Effect of multizone refractive multifocal contact lenses on the Cirrus HD OCT retinal measurements

2011

Background Simultaneous vision multifocal contact lenses are widely used to alleviate the symptoms of presbyopia. These contact lenses create simultaneous retinal images due to the incoming light distribution being divided into two or more focuses. Our aim was to evaluate whether the multizone refractive multifocal contact lenses affect the measurements of the retinal nerve fibre layer (RNFL) and macular thickness using optical coherence tomography (OCT). Methods In this cross-over study, 30 eyes of 30 subjects with a mean age of 50.42 ± 7.82 years were fitted with multizone refractive multifocal contact lenses. Using the RNFL Thickness Analysis mode of the Cirrus HD (Carl Zeiss, Meditec, D…

MaleRetinal Ganglion Cellsmedicine.medical_specialtyMaterials sciencegenetic structuresContact LensesVisual AcuityRefraction Ocularchemistry.chemical_compoundNerve FibersOpticsOptical coherence tomographySignal strengthOphthalmologymedicineHumansÓpticaCross-Over Studiesmedicine.diagnostic_testbusiness.industryRetinalEquipment DesignPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractioneye diseasesContact lensOphthalmologychemistryOftalmologíaFemaleCirrussense organsTomographybusinessTomography Optical CoherenceOptometryClinical and Experimental Optometry
researchProduct

Electrostimulation of the lingual nerve by an intraoral device may lead to salivary gland regeneration: A case series study

2018

Background Salivary gland function is controlled by the salivary reflex, whose efferent arm is composed by the parasympathetic and the sympathetic divisions of the autonomic nervous system. Parenchymal injury is the main salivary gland involvement of Sjögren’s syndrome and head and neck radiotherapy, but neural damage has been reported as well. Recently an intraoral device for electrostimulation of the lingual nerve in vicinity to the lower third molar has been introduced. At this point this nerve carries efferent fibers for the innervation of the submandibular, sublingual and several minor salivary glands and afferent fibers of the salivary reflex. Therefore, excitation of these fibers pot…

MaleSalivaPathologymedicine.medical_specialtyEfferentStimulationElectric Stimulation TherapyLingual NerveXerostomiaSalivary Glands03 medical and health sciences0302 clinical medicinestomatognathic systemmedicineHumansRegenerationGeneral DentistryLingual nerveAgedCross-Over StudiesOral Medicine and PathologySalivary glandbusiness.industryRegeneration (biology)Research030206 dentistryEquipment DesignMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Dry mouthAutonomic nervous systemmedicine.anatomical_structureOtorhinolaryngology030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASsalivary gland sjogren syndrome stimulationSurgeryFemalemedicine.symptombusiness
researchProduct

Long-term follow-up after drug eluting stent implantation in left main trifurcations

2009

Aims: Trifurcation lesions, which are mostly observed in distal left main (LM), represent a technical challenge for interventional cardiologists. We sought to determine the feasibility and long-term clinical outcome of drug eluting stent (DES) implantation in patients with LM coronary trifurcation lesions. Methods and results: All patients with clinically significant de novo LM trifurcation lesions, who refused coronary artery bypass surgery and were considered eligible for percutaneous coronary intervention (PCI), were consecutively enrolled in this study from November 2005 to February 2007. Eleven patients (65±9 years, 91% men) met all the inclusion criteria and underwent LM trifurcation …

MaleTarget lesionmedicine.medical_specialtyPaclitaxelmedicine.medical_treatmentTrifurcation lesions.Coronary DiseaseCoronary AngiographyCoronary artery bypass surgeryClinical endpointStentHumansMedicineMyocardial infarctionAgedSirolimusbusiness.industryAngioplastyStentPercutaneous coronary interventionDrug-Eluting StentsEquipment DesignMiddle Agedmedicine.diseaseCoronary VesselsDESTubulin ModulatorsSurgeryDrug-eluting stentConventional PCIFemaleRadiologyCardiology and Cardiovascular MedicinebusinessImmunosuppressive AgentsFollow-Up Studies
researchProduct

Efficacy and one-year outcomes of Luminor® paclitaxel-coated drug-eluting balloon in the treatment of popliteal artery atherosclerosis lesions

2021

Purpose: Reporting outcomes with a new generation paclitaxel eluting balloon (Luminor®; iVascular, Vascular, S.L.U., Barcelona, Spain) in the popliteal district. Endovascular treatment of popliteal artery atherosclerotic disease is still debated without definitive evidences. Methods: From January to June 2019, patients’ data presenting popliteal artery atherosclerotic diseases and treated with the Luminor® (iVascular) drug eluting balloon (DEB) were prospectively collected. Critical limb ischemia (CLI) or severe claudication associated with popliteal artery stenosis >50% were the inclusion criteria. Measured outcomes were technical success, early and late results; including mortality, mo…

MaleTime Factorsmedicine.medical_treatmentConstriction Pathologic030204 cardiovascular system & hematologySeverity of Illness IndexSettore MED/22 - Chirurgia Vascolare030218 nuclear medicine & medical imaging0302 clinical medicineRestenosisCoated Materials BiocompatibleIschemiaRecurrenceMedicineProspective StudiesAged 80 and overEndovascularCritical limb ischemiaGeneral MedicineEquipment DesignLimb SalvagePlaque AtheroscleroticTreatment OutcomeFemalemedicine.symptomCardiology and Cardiovascular MedicineVascular Access Devicesmedicine.medical_specialtyPaclitaxelPopliteal arteryCritical IllnessDrug eluting balloonAmputation Surgical03 medical and health sciencesPeripheral Arterial Diseasemedicine.arteryAngioplastyHumansVascular PatencyAgedbusiness.industryAngioplastyCardiovascular AgentsCritical limb ischemiaPerioperativeIntermittent Claudicationmedicine.diseasePopliteal arterySurgeryStenosisAmputationSurgerybusinessClaudicationAngioplasty Balloon
researchProduct

Initial experience with a new method of external polyester scaffolding for infrainguinal vein grafts.

2009

Abstract Objectives This study aims to evaluate the feasibility of external polyester scaffolding in infrainguinal bypass grafting when available vein material is suboptimal due to varicosity or dilatation. Primary objectives were short-term primary patency, assisted primary patency and secondary patency. Secondary objectives were to assess the rate of graft stenoses, infections and other adverse effects related to the use of external scaffolding. Materials and methods A total of 50 consecutive patients were included in this prospective, multicentre, feasibility study from six centres. The indication for infrainguinal bypass was critical limb ischaemia (64%), severe claudication (34%) or po…

MaleTime Factorsmedicine.medical_treatmentPilot ProjectsKaplan-Meier EstimateIschemiaMedicinePopliteal ArteryProspective StudiesExternal polyester mesh supportMedicine(all)Aged 80 and overPeripheral Vascular DiseasesUltrasonography Doppler DuplexGraft Occlusion VascularEquipment DesignMiddle Agedmedicine.anatomical_structureTreatment OutcomeLower ExtremityFemaleRadiologymedicine.symptomCardiology and Cardiovascular MedicineVascular Surgical ProceduresInfrainguinal bypassAdultReoperationmedicine.medical_specialtyInfrainguinal bypassPolyestersVein graftRevascularizationVeinsPopliteal aneurysmDuplex scanningEctasiaHumansSurgical Wound InfectionVeinVascular PatencyAgedbusiness.industryPhlebographyIntermittent ClaudicationSurgical MeshVein graftAneurysmSurgeryFeasibility StudiesSurgerybusinessClaudicationEuropean journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
researchProduct

Stereoacuity with balanced presbyopic contact lenses.

2010

Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…

MaleVisual acuitygenetic structuresContact LensesVisual AcuityContrast SensitivitymedicineHumansVision testDepth PerceptionVision BinocularVision TestsPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyEyeglassesReadingOftalmologíaOptometryFemalemedicine.symptomDepth perceptionPsychologyBinocular visionOptometryClinicalexperimental optometry
researchProduct

Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.

2011

Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…

MaleVisual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivitymedicineContrast (vision)HumansMathematicsmedia_commonAgedVision BinocularCross-Over StudiesColor VisionEquipment DesignPresbyopiaMiddle Agedeye diseasesStereoscopic acuityContact lensOphthalmologyStereopsisTreatment OutcomeOptometryFemalemedicine.symptomBinocular visionOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.

2014

Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …

MaleVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectLentes de contatoVisual AcuityPupilContrast Sensitivitylcsh:OphthalmologymedicineContrast (vision)HumansContact lensesPresbyopia/rehabilitationPupilaPresbiopia/reabilitaçãomedia_commonMathematicsCross-Over StudiesColor VisionPupilGeneral MedicinePresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseContact Lenses HydrophilicAjuste de próteseeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment Outcomelcsh:RE1-994Dominância ocularOptometryFemalemedicine.symptomProsthesis fitting dominance ocularPhotopic visionArquivos brasileiros de oftalmologia
researchProduct

Stereoacuity with simultaneous vision multifocal contact lenses.

2010

Our purpose was to evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses. In a cross-over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard-Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high-contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated. Mean SA with the Focus Progressive was 21 +/- 7 sec arc, 54 +/- 17 sec arc, and 51 +/- 21 sec arc, wit…

Malebusiness.product_categoryVisual acuitygenetic structuresContact LensesLentes de contactoVisual AcuityMedicineHumansVision testMultifocal lensesDepth PerceptionCross-Over Studiesbusiness.industryVision TestsEquipment DesignPresbyopiaMiddle AgedStereoscopic acuityOphthalmologyOptometryOftalmologíaFemalemedicine.symptomDepth perceptionbusinessOptometryOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

The influence of wearing ski-boots with different rigidity characteristics on postural control

2018

External supports that reduce ankle joint mobility such as ski-boots can impair postural control of healthy participants. Although this disruptive effect has been attributed to the rigidity of the external supports, the results remained controversial and no study has been conducted in order to evaluate the influence of ski-boots rigidity. Hence, the question about the influence of ankle support rigidity on postural control remains open. This study was therefore undertaken in order to investigate the effect of ski-boots rigidity on postural control. Ten healthy active participants were recruited. The wearing of soft and rigid ski-boots was compared to barefoot while standing on a seesaw gene…

Malemedicine.medical_specialtyAdolescentMovement0206 medical engineeringPhysical Therapy Sports Therapy and RehabilitationRigidity (psychology)02 engineering and technologyThighBarefootPostural controlSports EquipmentYoung Adult03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationSkiingotorhinolaryngologic diseasesmedicineHumansKneeOrthopedics and Sports MedicineForce platformMuscle SkeletalPostural BalanceHipElectromyographybusiness.industryMotor controlEquipment Design030229 sport sciencesmusculoskeletal system020601 biomedical engineeringTrunkBiomechanical PhenomenaShoesmedicine.anatomical_structureTime and Motion StudiesFemaleAnkleAnklebusinesshuman activitiesSports Biomechanics
researchProduct