Search results for "Equipment Design"
showing 10 items of 409 documents
Effect of multizone refractive multifocal contact lenses on the Cirrus HD OCT retinal measurements
2011
Background Simultaneous vision multifocal contact lenses are widely used to alleviate the symptoms of presbyopia. These contact lenses create simultaneous retinal images due to the incoming light distribution being divided into two or more focuses. Our aim was to evaluate whether the multizone refractive multifocal contact lenses affect the measurements of the retinal nerve fibre layer (RNFL) and macular thickness using optical coherence tomography (OCT). Methods In this cross-over study, 30 eyes of 30 subjects with a mean age of 50.42 ± 7.82 years were fitted with multizone refractive multifocal contact lenses. Using the RNFL Thickness Analysis mode of the Cirrus HD (Carl Zeiss, Meditec, D…
Electrostimulation of the lingual nerve by an intraoral device may lead to salivary gland regeneration: A case series study
2018
Background Salivary gland function is controlled by the salivary reflex, whose efferent arm is composed by the parasympathetic and the sympathetic divisions of the autonomic nervous system. Parenchymal injury is the main salivary gland involvement of Sjögren’s syndrome and head and neck radiotherapy, but neural damage has been reported as well. Recently an intraoral device for electrostimulation of the lingual nerve in vicinity to the lower third molar has been introduced. At this point this nerve carries efferent fibers for the innervation of the submandibular, sublingual and several minor salivary glands and afferent fibers of the salivary reflex. Therefore, excitation of these fibers pot…
Long-term follow-up after drug eluting stent implantation in left main trifurcations
2009
Aims: Trifurcation lesions, which are mostly observed in distal left main (LM), represent a technical challenge for interventional cardiologists. We sought to determine the feasibility and long-term clinical outcome of drug eluting stent (DES) implantation in patients with LM coronary trifurcation lesions. Methods and results: All patients with clinically significant de novo LM trifurcation lesions, who refused coronary artery bypass surgery and were considered eligible for percutaneous coronary intervention (PCI), were consecutively enrolled in this study from November 2005 to February 2007. Eleven patients (65±9 years, 91% men) met all the inclusion criteria and underwent LM trifurcation …
Efficacy and one-year outcomes of Luminor® paclitaxel-coated drug-eluting balloon in the treatment of popliteal artery atherosclerosis lesions
2021
Purpose: Reporting outcomes with a new generation paclitaxel eluting balloon (Luminor®; iVascular, Vascular, S.L.U., Barcelona, Spain) in the popliteal district. Endovascular treatment of popliteal artery atherosclerotic disease is still debated without definitive evidences. Methods: From January to June 2019, patients’ data presenting popliteal artery atherosclerotic diseases and treated with the Luminor® (iVascular) drug eluting balloon (DEB) were prospectively collected. Critical limb ischemia (CLI) or severe claudication associated with popliteal artery stenosis >50% were the inclusion criteria. Measured outcomes were technical success, early and late results; including mortality, mo…
Initial experience with a new method of external polyester scaffolding for infrainguinal vein grafts.
2009
Abstract Objectives This study aims to evaluate the feasibility of external polyester scaffolding in infrainguinal bypass grafting when available vein material is suboptimal due to varicosity or dilatation. Primary objectives were short-term primary patency, assisted primary patency and secondary patency. Secondary objectives were to assess the rate of graft stenoses, infections and other adverse effects related to the use of external scaffolding. Materials and methods A total of 50 consecutive patients were included in this prospective, multicentre, feasibility study from six centres. The indication for infrainguinal bypass was critical limb ischaemia (64%), severe claudication (34%) or po…
Stereoacuity with balanced presbyopic contact lenses.
2010
Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…
Visual performance comparison between contact lens-based pinhole and simultaneous vision contact lenses.
2011
Background The aim was to evaluate the visual performance provided with a contact lens-based pinhole design against a simultaneous vision multifocal contact lens. Methods In a cross-over study at the University of Valencia, 22 presbyopic patients were evaluated using an artificial pupil fitted on the non-dominant eye and the simultaneous vision PureVision Multifocal contact lenses. After one month of contact lens wear, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2). In addition, binocular distance vis…
Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction.
2014
Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC) on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA) were measured under photopic conditions (85 cd/m2). Moreover, BDVA and binocular distance contrast sensitivity were …
Stereoacuity with simultaneous vision multifocal contact lenses.
2010
Our purpose was to evaluate near stereoacuity (SA) with Focus Progressives and PureVision Multifocal simultaneous vision contact lenses. In a cross-over study design, 20 presbyopic subjects were fitted with either the Focus Progressives or PureVision Multifocal lenses. After 1 month, SA was measured with the vectographic Titmus, Random dot stereotests, and the Howard-Dolman apparatus under photopic conditions (85 lux) at 40 cm. Binocular high-contrast visual acuity at distance and near was examined. Subjects were then refitted with the alternative correction and the procedure was repeated. Mean SA with the Focus Progressive was 21 +/- 7 sec arc, 54 +/- 17 sec arc, and 51 +/- 21 sec arc, wit…
The influence of wearing ski-boots with different rigidity characteristics on postural control
2018
External supports that reduce ankle joint mobility such as ski-boots can impair postural control of healthy participants. Although this disruptive effect has been attributed to the rigidity of the external supports, the results remained controversial and no study has been conducted in order to evaluate the influence of ski-boots rigidity. Hence, the question about the influence of ankle support rigidity on postural control remains open. This study was therefore undertaken in order to investigate the effect of ski-boots rigidity on postural control. Ten healthy active participants were recruited. The wearing of soft and rigid ski-boots was compared to barefoot while standing on a seesaw gene…