Endoluminal therapy of GERD with a new endoscopic suturing device
2005
Background Endoscopic, endoluminal therapy might be an alternative treatment option in light of the costs of proton pump inhibitor therapy and possible complications after laparoscopic surgery. The aim of the current study was to assess the efficacy and the safety of a new endoluminal suture device (ESD) in pig models and humans. Secondly, 3 and 6 months' follow-ups were performed, and possible complications and their management were evaluated. Methods In the preclinical phase of the study, suturing procedures were practiced and evaluated in 8 pig models (Erlanger Endo Trainer). In the clinical phase, 20 patients with mild esophagitis, small or no hiatal hernia, and signs of abnormal acid e…
Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study
2019
AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Measurement of EMG activity with textile electrodes embedded into clothing.
2007
Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 person…
Determining the location of the body׳s center of mass for different groups of physically active people
2013
The purpose of the present study was to compare the location of the body center of mass (CoM) determined by using a high accuracy reaction board (RB) and two different segment parameter models for motion analysis (Dempster, 1955, DEM and de Leva, 1996 adjusted from Zatsiorsky and Seluyanov, ZAT). The body CoM (expressed as percentage of the total body height) was determined from several subjects including athletes as well as physically active students and sedentary people. Some significant differences were found in the location of the body CoM between the used segment models and the reaction board method for all male subjects (n=58, 57.03±0.79%, 56.20±0.76% and 57.60±0.76% for RB, ZAT and D…
Effects of the Breathe Right Nasal Strips on Nasal Ventilation
1997
The Breathe Right nasal strips are more and more commonly used, mainly by athletes, who hope to enhance their physical performance in competition and training. The effect of the device in such situations is uncertain and perhaps somewhat controversial. To investigate the effects of the nasal strips on nasal ventilation, 20 Caucasian individuals were objectively assessed using anterior rhinomanometry and acoustic rhinometry. The results showed a significant increase in all subjects of transnasal airflow and in the average cross-sectional area of the nasal cavity that quantifies objectively the subjective impression of improved nasal breathing. In such patients where an improvement in nasal …
Clinical evaluation of piezoelectric ear surgery
2008
We evaluated the use of piezoelectric surgery (Piezosurgery; Mectron Medical Technology; Carasco, Genoa, Italy) as a means of avoiding some complications of osteotomy and osteoplasty in otologic surgery, particularly in classic canal-wall-up mastoidectomy. Piezoelectric surgery is a recently developed system for cutting bone with microvibrations created by the piezoelectric effect. This effect occurs when an electric current is passed through certain ceramics and crystals, causing them to oscillate at ultrasonic frequencies. Our study population was made up of 20 adults with unilateral chronic otitis media. In all patients, piezoelectric surgery allowed for effective, precise, safe, easy, …
An alternative clinical routine for subjective refraction based on power vectors with trial frames.
2016
PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …
Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation
2003
Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…
Prevention of ventricular catheter obstruction and slit ventricle syndrome by the prophylactic use of the Integra antisiphon device in shunt therapy …
2010
Object This 25-year follow-up study was performed on 120 children with hypertensive hydrocephalus to evaluate the influence of the early prophylactic implantation of the Integra antisiphon device (ASD, Integra Neurosciences Ltd.) on the rate of proximal shunt obstructions and the frequency of symptomatic slit ventricle syndrome (SVS). The adaptability of the ASD to growth, proper positioning of the ASD as a necessity for its successful performance, and the 3 phases of SVS development are discussed. Method Since 1978, the ASD has consistently been implanted either at the time of primary shunt insertion (66 neonates, mean follow-up 11 years) or during revisions of preexisting shunts (54 chil…