Search results for "Equipment Failure Analysi"

showing 10 items of 123 documents

Pulse quality analysis on soliton pulse compression and soliton self-frequency shift in a hollow-core photonic bandgap fiber.

2013

A numerical investigation of low-order soliton evolution in a proposed seven-cell hollow-core photonic bandgap fiber is reported. In the numerical simulation, we analyze the pulse quality evolution in soliton pulse compression and soliton self-frequency shift in three fiber structures with different cross-section sizes. In the simulation, we consider unchirped soliton pulses (of 400 fs) at the wavelength of 1060 nm. Our numerical results show that the seven-cell hollow-core photonic crystal fiber, with a cross-section size reduction of 2%, promotes the pulse quality on the soliton pulse compression and soliton self-frequency shift. For an input soliton pulse of order 3 (which corresponds to…

Femtosecond pulse shapingPhysicsPhotonsOptical fiberbusiness.industryPhysics::OpticsSoliton (optics)Equipment DesignSurface Plasmon ResonancePulse shapingAtomic and Molecular Physics and Opticslaw.inventionPulse (physics)Equipment Failure AnalysisRefractometryOpticslawPulse compressionOptoelectronicsFiber Optic TechnologybusinessNonlinear Sciences::Pattern Formation and SolitonsUltrashort pulsePhotonic-crystal fiberOptics express
researchProduct

Multicomponent polymeric micelles based on polyaspartamide as tunable fluorescent pH-window biosensors

2010

Abstract PHEA-PEG 5000 -C 16 is a polyaspartamide polymer with appended hydrophilic PEG 5000 functions and hydrophobic n-C 16 units forming biocompatible micelles with a CAC as low as 1.8 × 10 −7  M. The protonation and acidity constants of the polymer's amino and carboxylic groups have been determined by potentiometric titrations at five different concentrations higher than CAC, finding concentration-independent values. Viscosity and polarity of the micellar core have been investigated by means of fluorescent probes, finding local values comparable to those of pure toluene and to the core of sodium dodecyl sulphate micelles, independently on the protonation degree of the polymer. The fluor…

FluorophorePolymeric micelles Fluorescent biosensor PH window Self-assemblinGInorganic chemistryPotentiometric titrationBiomedical EngineeringBiophysicsProtonationBiosensing TechniquesMicellePolyethylene Glycolschemistry.chemical_compoundElectrochemistryOrganic chemistryMicellesPolyhydroxyethyl Methacrylatechemistry.chemical_classificationEquipment DesignGeneral MedicinePolymerHydrogen-Ion ConcentrationEquipment Failure AnalysisSpectrometry FluorescencechemistrySettore CHIM/09 - Farmaceutico Tecnologico ApplicativoPyreneSelf-assemblyPeptidesBiosensorBiotechnologyBiosensors and Bioelectronics
researchProduct

Twin axial vortices generated by Fibonacci lenses.

2013

Optical vortex beams, generated by Diffractive Optical Elements (DOEs), are capable of creating optical traps and other multifunctional micromanipulators for very specific tasks in the microscopic scale. Using the Fibonacci sequence, we have discovered a new family of DOEs that inherently behave as bifocal vortex lenses, and where the ratio of the two focal distances approaches the golden mean. The disctintive optical properties of these Fibonacci vortex lenses are experimentally demonstrated. We believe that the versatility and potential scalability of these lenses may allow for new applications in micro and nanophotonics.

Fresnel zoneFibonacci numberDevils vortex-lensesLightNanophotonicsPhysics::OpticsMicroscopic scaleOpticsLight beamScattering RadiationGolden ratioComputer SimulationDiffractive opticsLensesPhysicsOptical vorticesbusiness.industryFractal zone platesEquipment DesignModels TheoreticalAtomic and Molecular Physics and OpticsVortexEquipment Failure AnalysisRefractometryFISICA APLICADAComputer-Aided DesignbusinessOptical vortexDiffractionOptics express
researchProduct

Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.

2014

In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields…

HDR brachytherapyMaterials sciencesuperficial and interstitialmedicine.medical_treatmentBrachytherapyBrachytherapydosimetric perturbationModels BiologicalSensitivity and SpecificityImaging phantomLead shieldingOpticsRadiation ProtectionShieldBody surfacemedicineHumansScattering RadiationComputer SimulationRadiometryWaste Management and DisposalMonte Carlo simulationbusiness.industrytransmissionPublic Health Environmental and Occupational HealthAbsorption RadiationReproducibility of ResultsRadiotherapy DosageGeneral MedicineEquipment DesignHigh-Dose Rate BrachytherapyEquipment Failure AnalysisLeadElectromagnetic shieldinglead shieldbusinessNuclear medicineBolus (radiation therapy)Journal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Risk assessment of component failure modes and human errors using a new FMECA approach: application in the safety analysis of HDR brachytherapy

2014

Failure mode, effects and criticality analysis (FMECA) is a safety technique extensively used in many different industrial fields to identify and prevent potential failures. In the application of traditional FMECA, the risk priority number (RPN) is determined to rank the failure modes; however, the method has been criticised for having several weaknesses. Moreover, it is unable to adequately deal with human errors or negligence. In this paper, a new versatile fuzzy rule-based assessment model is proposed to evaluate the RPN index to rank both component failure and human error. The proposed methodology is applied to potential radiological over-exposure of patients during high-dose-rate brach…

HDR brachytherapySafety ManagementComputer sciencemedicine.medical_treatmentBrachytherapyHuman errorBrachytherapyRisk AssessmentRadiation ProtectionComponent (UML)medicineHumansComputer SimulationRadiation InjuriesWaste Management and Disposalhuman errorSettore ING-IND/19 - Impianti Nuclearirisk priority numberModels StatisticalFuzzy ruleMedical ErrorsIncidenceRank (computer programming)Public Health Environmental and Occupational HealthGeneral MedicineReliability engineeringEquipment Failure AnalysisSurvival RateFailure mode effects and criticality analysisEquipment FailurePatient Safetyfuzzy logicRadioactive Hazard ReleaseRisk assessmentFailure mode and effects analysisFMECA
researchProduct

Sub-critical filtration conditions of commercial hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system: The effect of gas sparging i…

2012

A submerged anaerobic MBR demonstration plant with two commercial hollow-fibre ultrafiltration systems (PURON®, Koch Membrane Systems, PUR-PSH31) was operated using municipal wastewater at high levels of mixed liquor total solids (MLTS) (above 22gL -1). A modified flux-step method was applied to assess the critical flux (J C) at different gas sparging intensities. The results showed a linear dependency between J C and the specific gas demand per unit of membrane area (SGD m). J C ranged from 12 to 19LMH at SGD m values of between 0.17 and 0.5Nm 3h -1m -2, which are quite low in comparison to aerobic MBR. Long-term trials showed that the membranes operated steadily at fluxes close to the est…

Hollow-fibre membraneINGENIERIA HIDRAULICABiofoulingMicrofiltrationModified flux-step methodUltrafiltrationWastewaterSludgelaw.inventionGas spargingBioreactorslawFlux-step methodCritical fluxWaste Management and DisposalSpargingHollow fiber membranePriority journalWaste water managementChemistryMembraneGeneral MedicineEquipment DesignHollow fiber reactorMembraneGasesWaste waterPorosityAnaerobic membrane bioreactorEnvironmental EngineeringUltrafiltrationBioreactorBioengineeringWater filtrationArticleBacteria AnaerobicBioreactorMicrofiltrationIndustrial hollow-fibre membranesFiltrationTECNOLOGIA DEL MEDIO AMBIENTESubmerged anaerobic membrane bioreactorChromatographyMembranesFoulingRenewable Energy Sustainability and the EnvironmentLong-term changeMembranes ArtificialEquipment Failure AnalysisHollow fiber membraneComparative studyAnoxic conditions
researchProduct

Revisited BIA-MS combination: Entire "on-a-chip" processing leading to the proteins identification at low femtomole to sub-femtomole levels

2008

International audience; We present the results of a study in which biomolecular interaction analysis (BIA, Biacore 2000) was combined with mass spectrometry (MS) using entire "on-a-chip" procedure. Most BIA-MS studies included an elution step of the analyte prior MS analysis. Here, we report a low-cost approach combining Biacore analysis with homemade chips and MS in situ identification onto the chips without elution step. First experiments have been made with rat serum albumin to determine the sensitivity and validation of the concept has been obtained with an antibody/antigen couple. Our "on-a-chip" procedure allowed complete analysis by MS-MS of the biochip leading to protein identificat…

In situMALDI-TOFAnalyte[ SDV.BBM.BP ] Life Sciences [q-bio]/Biochemistry Molecular Biology/BiophysicsBiomedical EngineeringBiophysicsAnalytical chemistrySPRBiosensing TechniquesMass spectrometry01 natural sciencesSensitivity and Specificity03 medical and health sciencesProtein Interaction MappingElectrochemistryNanotechnologyBIA-MSBiochipChromatography High Pressure Liquid030304 developmental biology0303 health sciencesChromatographyprotein complexesElutionChemistryMicrochemistry010401 analytical chemistryMs analysisReproducibility of ResultsGeneral MedicineEquipment DesignMicrofluidic Analytical Techniques0104 chemical sciencesEquipment Failure Analysis[SDV.BBM.BP]Life Sciences [q-bio]/Biochemistry Molecular Biology/BiophysicsMatrix-assisted laser desorption/ionizationSAMSpectrometry Mass Matrix-Assisted Laser Desorption-IonizationBiotechnology
researchProduct

Recycling of 3He from lung magnetic resonance imaging

2011

We have developed the means to recycle 3He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized 3He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1–2% of 3He, depending on the amount administered and the number of breaths collected to wash out the 3He gas from the lungs. 3He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled 3He gas features high purity, which is required for repolarization by metastability ex…

Leakbusiness.product_categoryContrast Mediachemistry.chemical_elementMolecular sieveHeliumAdsorptionIsotopesGetterImpurityAdministration InhalationBottlemedicineHumansRecyclingRadiology Nuclear Medicine and imagingLungHeliumChromatographymedicine.diagnostic_testChemistryMagnetic resonance imagingEquipment DesignMagnetic Resonance ImagingEquipment Failure AnalysisExhalationRadiopharmaceuticalsbusinessMagnetic Resonance in Medicine
researchProduct

Tunable Strong Coupling of Mechanical Resonance between Spatially Separated FePS3 Nanodrums

2021

Coupled nanomechanical resonators made of two-dimensional materials are promising for processing information with mechanical modes. However, the challenge for these types of systems is to control the coupling. Here, we demonstrate strong coupling of motion between two suspended membranes of the magnetic 2D material FePS$_3$. We describe a tunable electromechanical mechanism for control over both the resonance frequency and the coupling strength using a gate voltage electrode under each membrane. We show that the coupling can be utilized for transferring data from one drum to the other by amplitude modulation. Finally, we also study the temperature dependence of the coupling, and in particul…

LetterResonance structuresFOS: Physical sciencesBioengineeringApplied Physics (physics.app-ph)02 engineering and technologyTwo-dimensional materials01 natural sciencesVibrationCouplingMotionMesoscale and Nanoscale Physics (cond-mat.mes-hall)0103 physical sciencesMagnetic propertiesGeneral Materials Science010306 general physicsMembranesCondensed Matter - Mesoscale and Nanoscale PhysicsMechanical EngineeringPhysics - Applied PhysicsGeneral ChemistryEquipment DesignMicro-Electrical-Mechanical Systems021001 nanoscience & nanotechnologyCondensed Matter PhysicsEquipment Failure AnalysisOscillation0210 nano-technologyNano Letters
researchProduct

Development of a long-lasting ventricular catheter impregnated with a combination of antibiotics.

2003

A ventricular silicone catheter impregnated with a combination of rifampin and a quinolone was developed in order to prevent ventricular shunt related infections. As model substance for the quinolones we used sparfloxacin, because of its specific physicochemical properties resulting in a quantitative detection also in the presence of a second antibiotic. In our study we focused especially on an optimization of the antibiotic release out of the impregnated catheters in order to develop long lasting devices with a broad antimicrobial spectrum. A release-optimized catheter was tested with an in vitro colonization test and additionally with a method developed to examine the spread of bacteria o…

Long lastingmedicine.medical_specialtyProsthesis-Related Infectionsmedicine.drug_classAntibioticsBiophysicsBioengineeringQuinolonesCerebral VentriclesBiomaterialschemistry.chemical_compoundSiliconeCatheters IndwellingDrug Delivery SystemsCoated Materials BiocompatibleStaphylococcus epidermidismedicineStaphylococcus epidermidisDrug Implantsbiologybusiness.industrySterilizationbiology.organism_classificationAntimicrobialQuinoloneSurgeryAnti-Bacterial AgentsEquipment Failure AnalysisCatheterSparfloxacinchemistryMechanics of MaterialsCeramics and CompositesEquipment ContaminationDrug Therapy CombinationRifampinbusinessmedicine.drugBiomaterials
researchProduct