Search results for "Equipment"

showing 10 items of 1271 documents

Prevention of ventricular catheter obstruction and slit ventricle syndrome by the prophylactic use of the Integra antisiphon device in shunt therapy …

2010

Object This 25-year follow-up study was performed on 120 children with hypertensive hydrocephalus to evaluate the influence of the early prophylactic implantation of the Integra antisiphon device (ASD, Integra Neurosciences Ltd.) on the rate of proximal shunt obstructions and the frequency of symptomatic slit ventricle syndrome (SVS). The adaptability of the ASD to growth, proper positioning of the ASD as a necessity for its successful performance, and the 3 phases of SVS development are discussed. Method Since 1978, the ASD has consistently been implanted either at the time of primary shunt insertion (66 neonates, mean follow-up 11 years) or during revisions of preexisting shunts (54 chil…

AdultMaleReoperationmedicine.medical_specialtyAdolescentIntracranial PressureHydrostatic pressureInfant Premature DiseasesSlit Ventricle SyndromeCentral nervous system diseaseYoung AdultPostoperative ComplicationsRisk FactorsHydrostatic PressuremedicineHumansYoung adultChildbusiness.industryInfant NewbornInfantEquipment DesignGeneral Medicinemedicine.diseaseSlit Ventricle SyndromeCerebrospinal Fluid ShuntsHydrocephalusSurgeryEquipment Failure AnalysisCatheterEl NiñoChild PreschoolFemaleIntracranial HypertensionbusinessShunt (electrical)Follow-Up StudiesHydrocephalusJournal of Neurosurgery: Pediatrics
researchProduct

A dangerous design for a mountain bike.

2001

The case of a man’s death as a consequence of an accident with a mountain bike was examined. Despite only slight external injuries, a general examination revealed the existence of a rupture of the diaphragm which was the ultimate cause of death. The discussion reconstructs the way the accident occurred and briefly analyses the consequences of safety design in two-wheeled vehicles.

AdultMaleRuptureEngineeringbusiness.industrySafety designDiaphragmDiaphragm (mechanical device)Equipment DesignPathology and Forensic MedicineBicyclingCause of DeathForensic engineeringHumansbusinesshuman activitiesCause of deathInternational journal of legal medicine
researchProduct

Towards Improved Healthcare Performance: Examining Technological Possibilities and Patient Satisfaction with Wireless Body Area Networks

2009

Published version of an article from the journal: Journal of Medical Systems. he original publication is available at Springerlink. http://dx.doi.org/10.1007/s10916-009-9291-8 This paper investigates the benefits of using less intrusive wireless technologies for heart monitoring. By replacing well established heart monitoring devices (i.e. Holter) with wireless ECG based Body Area Networks (BAN), improved healthcare performance can be achieved, reflected in (1) high quality ECG recordings during physical activities and (2) increased patient satisfaction. A small scale clinical trial was conducted to compare both technologies and the results illustrate that the wireless ECG monitor was able …

AdultMaleTelemedicineAdolescentComputer scienceRemote patient monitoringmedicine.medical_treatmentmedia_common.quotation_subjecteducationMedicine (miscellaneous)Health InformaticsHealth informaticsYoung AdultPatient satisfactionHealth Information ManagementmedicineHumansWirelessVDP::Medical disciplines: 700::Health sciences: 800::Health service and health administration research: 806ComputerSystemsOrganization_SPECIAL-PURPOSEANDAPPLICATION-BASEDSYSTEMSQuality (business)cardiovascular diseasesChildAgedmedia_commonbusiness.industryLocal area networkArrhythmias CardiacVDP::Technology: 500::Information and communication technology: 550Middle AgedLocal Area Networksequipment and suppliesTelemedicineRisk analysis (engineering)Patient SatisfactionElectrocardiography AmbulatoryFemaleCardiac monitoringbusinessTelecommunicationsInformation Systems
researchProduct

Local Gingival Blood Flow at Healthy and Inflamed Sites Measured by Laser Doppler Flowmetry

2006

This investigation aimed to: 1) develop a method to obtain reproducible laser Doppler flow readings (LDFRs) at the gingiva of the maxillary front teeth; 2) evaluate regional gingival blood flow (GBF) in healthy gingiva by laser Doppler flowmetry; 3) compare hand-held LDFR (H-LDFR) with splint LDFR (S-LDFR); and 4) monitor changes in GBF in experimental gingivitis (EG) and chronic gingivitis (CG).The LDFR, gingival index (GI), and plaque index (PI) were measured at 13 gingival sites (teeth #6 to #11) in 10 healthy volunteers (five males and five females), 23 to 34 years of age, over a period of 12.5 +/- 3.27 days employing a partial-mouth EG model and in 11 patients (three males and eight fe…

AdultMaleToothbrushingCuspidPlaque indexGingivaDentistryGingivitisHealthy volunteersLaser-Doppler FlowmetryMaxillaHumansMedicineLaser doppler flowbusiness.industryDental Plaque IndexReproducibility of ResultsEquipment DesignBlood flowMiddle AgedLaser Doppler velocimetryGingivitisIncisorGingival indexRegional Blood FlowChronic DiseasePeriodonticsFemalePeriodontal Indexmedicine.symptombusinessChronic gingivitisJournal of Periodontology
researchProduct

Plaque removal efficacy of power and manual toothbrushes: a comparative study

2009

The aim of this study was to compare the plaque removal efficacy of a new oscillating/rotating/pulsating toothbrush [Oral-B® Professional Care® 8500 (PC 8500)] with two manual toothbrushes [Oral-B® CrossAction™ Vitalizer (CAV) and Oral-B® Indicator™ (IND), respectively]. The safety of the PC 8500 was also assessed. The study was a single-use, observer-masked, randomised 3×3 Latin square crossover design balanced for carryover effects. The enrolled subjects (n=66) refrained from brushing for 23–25 h before each clinical examination. Plaque scores were recorded before and after brushing with the allocated toothbrush using the Turesky et al. modification of the Quigley and Hein plaque index. T…

AdultMaleToothbrushingPlaque indexAdolescentPlaque removalPlaque removalDental PlaqueDentistryManual toothbrushPlaque controlStatistics Nonparametriclaw.inventionDental Devices Home CareRandomised crossover single-use studyPower toothbrushYoung AdultElectricitylawSettore MED/28 - Malattie OdontostomatologicheMedicineHumansSingle-Blind MethodManual toothbrushGeneral DentistryAnalysis of VarianceChi-Square DistributionCross-Over StudiesEquipment Safetybusiness.industryDental Plaque IndexMiddle AgedCrossover studyDental Plaque IndexSafety EquipmentPlaque indexFemaleToothbrushSafetybusiness
researchProduct

Efficacy of 3 toothbrush treatments on plaque removal in orthodontic patients assessed with digital plaque imaging: a randomized controlled trial.

2013

Good oral hygiene is a challenge for orthodontic patients because food readily becomes trapped around the brackets and under the archwires, and appliances are an obstruction to mechanical brushing. The purpose of this study was to compare plaque removal efficacy of 3 toothbrush treatments in orthodontic subjects.This was a replicate-use, single-brushing, 3-treatment, examiner-blind, randomized, 6-period crossover study with washout periods of approximately 24 hours between visits. Forty-six adolescent and young adult patients with fixed orthodontics from a university clinic in Germany were randomized, based on computer-generated randomization, to 1 of 3 treatments: (1) oscillating-rotating …

AdultMaleToothbrushingRandomizationAdolescentPlaque removalElectrical Equipment and SuppliesDental PlaqueDentistryOrthodonticsManual toothbrushlaw.inventionYoung AdultRandomized controlled trialOrthodontic ApplianceslawImage Processing Computer-AssistedMedicineHumansSingle-Blind MethodChildFluorescent DyesOrthodonticsCross-Over Studiesbusiness.industryBrushEquipment DesignCrossover studyTreatment OutcomePhotography DentalPlaque imagingFemaleFluoresceinToothbrushbusinessAmerican journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
researchProduct

Response of the aging eye to first day of modern material contact lens wear

2018

Objectives: To investigate the ocular surface of an aged population wearing a daily disposable contact lens over their first day of wear. Methods: Forty eyes from forty presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA) and ocular surface aberrations (total higher order root means square (RMS)) were assessed at baseline (t0), at 20 minutes (t1) and after 8 hours (t2) of wear. Fluorescein corneal and conjunctival staining and tear break up time (TBUT) were performed at t0 and t2. Results: No statistically significant changes were found between t0, t1 and t2 for TMA, and between t0 and t2 for fluorescein corneal and conjunctival staining. TBUT…

AdultMaleUlls Acomodació i refracciómedicine.medical_specialtyAgingPopulationBaseline levelCornea03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOphthalmologymedicineHumansProspective StudiesFluoresceineducationDisposable EquipmentVision OcularOsmoleeducation.field_of_studyOsmotic concentrationbusiness.industryOsmolar ConcentrationEquipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicTear osmolarityeye diseasesÒptica Aparells i instrumentsContact lensOphthalmologyTear meniscuschemistryPatient SatisfactionTears030221 ophthalmology & optometryDry Eye SyndromesFemalesense organsbusinessConjunctiva030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

EchoScopy in scanning abdominal diseases: initial clinical experience.

2014

Background and Aims: The introduction of a new type of small handheld ultrasound device brings greater portability and affordability. The basic ultrasound approach with these handheld devices has been defined by European Federation of Societies of Ultrasound in Medicine and Biology (EFSUMB) as “EchoScopy”. The current study aimed to assess the image quality, indications and limitations of a portable pocket “EchoScope” compared with a high-end ultrasound system in abdominal diseases. Methods: 231 consecutive patients were included in this study. Physician A performed ultrasound examinations with a high-end ultrasound system (HEUS), then physician B performed the same ultrasound examination u…

AdultMaleUrologic Diseasesmedicine.medical_specialtyAdolescentImage qualityDigestive System DiseasesPilot ProjectsEndocrine System DiseasesSensitivity and SpecificityLesionYoung AdultVascularityAscitesAbdomenMedicineHumansUltrasonography Doppler ColorProspective cohort studyChildPathologicalHydronephrosisAgedAged 80 and overMiniaturizationbusiness.industryUltrasoundGastroenterologyReproducibility of ResultsEquipment DesignMiddle Agedmedicine.diseaseEquipment Failure AnalysisCardiovascular DiseasesFemaleRadiologymedicine.symptombusinessZeitschrift fur Gastroenterologie
researchProduct

Stone-Free Rate after Treating Kidney Stones Exceeding 10 mm via Flexible Ureteroscopy: Can Endoscopic Assessment Replace Low-Dose Computed Tomograph…

2019

<b><i>Introduction:</i></b> It is unclear whether endoscopic assessment of the stone-free rate after flexible ureteroscopy (fURS) is as effective as assessment with low-dose computed tomography (CT) scan. <b><i>Methods:</i></b> Prospective documentation of patients with kidney stones > 10 mm diameter from 2 different centers (Freiburg, Regensburg), who underwent fURS and were declared to be endoscopically completely stone-free. Low-dose CT control performed 4–8 weeks postoperatively. <b><i>Results/Conclusion:</i></b> Thirty-eight patients were treated between October 2015 and August 2016 (12 F, 26 M). Average a…

AdultMaleUrologyStone freemedicine.medical_treatment030232 urology & nephrologyComputed tomographyFlexible ureteroscopyLithotripsyRadiation Dosage03 medical and health sciencesKidney CalculiYoung Adult0302 clinical medicinemedicineUreteroscopyHumansUreteroscopyProspective StudiesAged2. Zero hungerAged 80 and overmedicine.diagnostic_testbusiness.industryLow doseRemission InductionEquipment DesignMiddle Agedmedicine.disease3. Good healthTreatment Outcome030220 oncology & carcinogenesisUreteroscopesKidney stonesFemaleStone removalbusinessNuclear medicineTomography X-Ray ComputedUrologia internationalis
researchProduct

Endoscopic Procedures through the Foramen Interventriculare of Monro under Stereotactical Conditions

1994

The foramen interventriculare of Monro is an anatomical narrowness for the endoscopic access to the third ventricle. The effective mechanical angle to pass the foramen interventriculare from a frontal bore hole depends on the diameter in the plane of entrance, the depth of the foramen, and the diameter of the endoscope. Under the pathological conditions of a hydrocephalus internus the foramen interventriculare is enlarged. By means of stereotactical guidance, it is possible to reach the third ventricle accurately without damaging anatomical structures around the foramen interventriculare. The endoscopic technique under stereotactical guidance using a rigid endoscope is sufficient and safe t…

AdultMaleVentriculostomymedicine.medical_specialtyAdolescentEndoscopeBiopsymedicine.medical_treatmentPerforation (oil well)Constriction PathologicAstrocytomaCerebral VentriclesVentriculostomyStereotaxic Techniquesstomatognathic systemmedicineForamenHumansChildAgedEndoscopesBrain DiseasesThird ventricleColloid cystmedicine.diagnostic_testBrain NeoplasmsCystsbusiness.industryEndoscopyEquipment DesignGeneral MedicineMiddle Agedmedicine.diseaseHydrocephalusEndoscopybody regionsmedicine.anatomical_structureChild Preschoolcardiovascular systemFemaleSurgeryNeurology (clinical)RadiologyEmergenciesbusinessmin - Minimally Invasive Neurosurgery
researchProduct