PROSAIKA: A prospective multicenter registry with the first programmable gravitational device for hydrocephalus shunting
2015
Abstract Objective Cerebrospinal fluid (CSF) overdrainage is a major problem in shunt therapy for hydrocephalus. The adjustable gravitational valve proSA allows for the first time a targeted compensation for overdrainage in the upright position without interfering with the differential pressure valve. To evaluate benefit, safety and reliability, the multicenter prospective registry PROSAIKA was conducted in 10 German neurosurgical centers. Methods Between March 2009 and July 2010, 120 hydrocephalic patients undergoing first time shunt implantation or shunt revision using proSA entered the study. 93 patients completed the 12 months follow-up. Results Hydrocephalus symptoms were improved in 8…
Operative Treatment of Scoliosis With Cotrel-Dubousset-Hopf Instrumentation
1997
Study design This study analyzes the effects of a new anterior spinal instrumentation system and the results of use in 50 patients with scoliosis. Objectives Anterior spine systems are reviewed. The principles of a new anterior spinal instrumentation system allowing for postoperative care without external support are discussed. Summary of background data Numerous different implants have been presented in the literature for anterior spinal surgery. Nevertheless a primary stable anterior instrumentation was not available for multisegmental procedures until now, and the restoration of lordosis in the lumbar spine was very difficult with the common devices. The development of more stable device…
Handling forces for the use of different inhaler devices.
2019
Abstract Age and comorbidities can impact on the success of handling an inhaler. In this pilot study, we assessed finger strength in 62 participants (aged 5–17 years [n = 20], 18–65 years [n = 22] and > 65 years [n = 20]) by using different types of inhalers with integrated sensors (Respimat®, Breezhaler®, Aerolizer®, Genuair®, Diskus®, Ellipta®, HandiHaler®, Turbohaler® and a pressurized metered-dose inhaler [Atrovent®]). Parameters under investigation included the spontaneous and maximum achievable force and torque required to operate devices. Satisfaction with individual inhalers, and the relationship between satisfaction and strength, were also assessed. There was a marked difference in…
Accuracy of magnetic resonance enterography in the preoperative assessment of patients with Crohn's disease of the small bowel
2016
Aim to assess the accuracy of magnetic resonance-enterography in predicting the extension, location and characteristics of the small bowel segments affected by Crohn's disease. Method This is a prospective study including a consecutive series of 38 patients with small bowel Crohn's disease who underwent surgery at a specialized colorectal unit of a tertiary hospital. Preoperative magnetic resonance enterography was performed in all patients, following a homogeneous protocol, within the three months prior to surgery. A thorough exploration of the small bowel was performed during the surgical procedure, using calibration spheres, according to the discretion of the surgeon. The accuracy of mag…
Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system
2014
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…
Prospective randomized comparison of short-access mother-baby cholangioscopy versus direct cholangioscopy with ultraslim gastroscopes
2012
Mother-baby technologies, the criterion standard for cholangioscopy, have several limitations. A novel, short-access, mother-baby (SAMBA) system may improve this technique. Direct cholangioscopy (DC) was recently developed as an alternative to mother-baby cholangioscopy.Comparison of success rates with SAMBA and DC.Single-center, randomized, controlled trial.Academic tertiary-care referral center.Sixty patients with suspected cholangiopathies randomized to either SAMBA (n = 30) or DC (n = 30).Cholangioscopy under deep sedation.Technical success rate of diagnostic or therapeutic procedure.A total of 24 and 21 diagnostic procedures were performed in the SAMBA and DC groups, respectively. Ther…
Case study: effect of handrim diameter on performance in a paralympic wheelchair athlete.
2009
This study, with a top T-52 class athlete, determines the relationship between stroke frequency (SF) and push time (PT) and wheelchair velocity (Wv) using different handrim diameters (HD) and the effect of different HDs on the athlete’s heart rate (HR) and blood lactate (LACT) at competition speeds. Wv shows a linear-direct relationship with SF but a linear-inverse relationship with PT (p < .001 in both cases). Using bigger handrims (0.37 m instead of 0.36 m), SF increases 6%, while PT decreases 27% (at 24 Km·h–1). HR (p < .0001) increases with Wv and is also affected by HD with differences between the 0.34 m—0.36 m handrim group (lower values) and the 0.37 m handrim (higher values). …
Subfascial Endoscopic Perforator Surgery With Tumescent Local Anesthesia
2002
background. Subfascial endoscopic perforator surgery (SEPS) has become an established procedure. objective. To evaluate SEPS with tumescent local anesthesia (TLA) using an single-port device originally designed for that purpose. methods. Patients selected for SEPS received subcutaneous infiltration of TLA into the medial aspect of the calf 20 minutes before surgery. Bipolar coagulation and dissection were used to treat incompetent perforators. results. Fifty-one patients with 67 legs of CEAP stages C3–C6 underwent SEPS with TLA. In 40 patients or 53 legs (79.1%) TLA alone allowed successful completion of the SEPS procedure. Five patients with 7 legs (10.4%) required additional intravenous a…
Effect of custom-made and prefabricated insoles on plantar loading parameters during running with and without fatigue.
2014
Controversy exists whether custom-made insoles are more effective in reducing plantar loading compared to prefabricated insoles. Forty recreational athletes ran using custom-made, prefabricated, and the original insoles of their running shoes, at rest and after a fatigue run. Contact time, stride rate, and plantar loading parameters were measured. Neither the insole conditions nor the fatigue state modified contact time and stride rate. Addressing prevention of running injuries, post-fatigue loading values are of great interest. Custom-made insoles reduced the post-fatigue loading under the hallux (92 vs. 130 kPa, P0.05), medial midfoot (70 vs. 105 kPa, P0.01), and lateral midfoot (62 vs 96…
Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: resu…
1999
Whether the safety and efficacy of implantable cardioverter defibrillator (ICD) therapy can be assured with lower output devices is an important question. The purpose of this study was to evaluate whether programming the device output at twice the augmented defibrillation threshold was as safe and effective as using the maximum energy. Patients indicated for ICD therapy, but without slow monomorphic ventricular tachycardia (MVT), who achieved an augmented defibrillation threshold (DFT plus)or = 15 joules (J) with a single endocardial lead system and a biphasic defibrillator were included in the study. Prior to ICD implantation, patients were randomized into 2 groups. The shock energies in t…