PROSAIKA: A prospective multicenter registry with the first programmable gravitational device for hydrocephalus shunting

2015

Abstract Objective Cerebrospinal fluid (CSF) overdrainage is a major problem in shunt therapy for hydrocephalus. The adjustable gravitational valve proSA allows for the first time a targeted compensation for overdrainage in the upright position without interfering with the differential pressure valve. To evaluate benefit, safety and reliability, the multicenter prospective registry PROSAIKA was conducted in 10 German neurosurgical centers. Methods Between March 2009 and July 2010, 120 hydrocephalic patients undergoing first time shunt implantation or shunt revision using proSA entered the study. 93 patients completed the 12 months follow-up. Results Hydrocephalus symptoms were improved in 8…

AdultMalemedicine.medical_specialtyAdolescentDifferential pressureVentriculoperitoneal ShuntYoung Adult03 medical and health sciences0302 clinical medicineClinical reportCerebrospinal fluidmedicineHumansProspective StudiesRegistriesChildSurvival rateAgedAged 80 and overbusiness.industryInfantEquipment DesignGeneral MedicineMiddle Agedmedicine.diseaseShunt surgeryCerebrospinal Fluid Shunts3. Good healthHydrocephalusSurgeryShuntingChild Preschool030220 oncology & carcinogenesisEquipment FailureFemaleSurgeryNeurology (clinical)business030217 neurology & neurosurgeryShunt (electrical)Follow-Up StudiesGravitationHydrocephalusClinical Neurology and Neurosurgery
researchProduct

Operative Treatment of Scoliosis With Cotrel-Dubousset-Hopf Instrumentation

1997

Study design This study analyzes the effects of a new anterior spinal instrumentation system and the results of use in 50 patients with scoliosis. Objectives Anterior spine systems are reviewed. The principles of a new anterior spinal instrumentation system allowing for postoperative care without external support are discussed. Summary of background data Numerous different implants have been presented in the literature for anterior spinal surgery. Nevertheless a primary stable anterior instrumentation was not available for multisegmental procedures until now, and the restoration of lordosis in the lumbar spine was very difficult with the common devices. The development of more stable device…

AdultMalemedicine.medical_specialtyAdolescentLordosisRadiographyScoliosisPostoperative ComplicationsmedicineDeformityHumansOrthopedics and Sports MedicineChildRachisFixation (histology)business.industryEquipment Designmedicine.diseaseSagittal planeOrthopedic Fixation DevicesSurgeryRadiographyTreatment Outcomemedicine.anatomical_structureScoliosisOrthopedic surgeryFemaleNeurology (clinical)medicine.symptombusinessFollow-Up StudiesSpine
researchProduct

Handling forces for the use of different inhaler devices.

2019

Abstract Age and comorbidities can impact on the success of handling an inhaler. In this pilot study, we assessed finger strength in 62 participants (aged 5–17 years [n = 20], 18–65 years [n = 22] and > 65 years [n = 20]) by using different types of inhalers with integrated sensors (Respimat®, Breezhaler®, Aerolizer®, Genuair®, Diskus®, Ellipta®, HandiHaler®, Turbohaler® and a pressurized metered-dose inhaler [Atrovent®]). Parameters under investigation included the spontaneous and maximum achievable force and torque required to operate devices. Satisfaction with individual inhalers, and the relationship between satisfaction and strength, were also assessed. There was a marked difference in…

AdultMalemedicine.medical_specialtyAdolescentPharmaceutical SciencePilot Projects02 engineering and technology030226 pharmacology & pharmacyFingers03 medical and health sciencesYoung Adult0302 clinical medicineAge groupsRheumatic DiseasesAdministration InhalationMedicineHumansChildAgedAged 80 and overHand Strengthbusiness.industryInhalerNebulizers and VaporizersHealthy subjectsAge FactorsRheumatic diseaseEquipment DesignMiddle Aged021001 nanoscience & nanotechnologyPatient preferenceDry-powder inhalerPatient SatisfactionCase-Control StudiesChild PreschoolPhysical therapyFemale0210 nano-technologybusinessInternational journal of pharmaceutics
researchProduct

Accuracy of magnetic resonance enterography in the preoperative assessment of patients with Crohn's disease of the small bowel

2016

Aim to assess the accuracy of magnetic resonance-enterography in predicting the extension, location and characteristics of the small bowel segments affected by Crohn's disease. Method This is a prospective study including a consecutive series of 38 patients with small bowel Crohn's disease who underwent surgery at a specialized colorectal unit of a tertiary hospital. Preoperative magnetic resonance enterography was performed in all patients, following a homogeneous protocol, within the three months prior to surgery. A thorough exploration of the small bowel was performed during the surgical procedure, using calibration spheres, according to the discretion of the surgeon. The accuracy of mag…

AdultMalemedicine.medical_specialtyAdolescentsurgical treatmentCrohn's DiseaseConstriction Pathologic030230 surgerySensitivity and SpecificityYoung Adult03 medical and health sciences0302 clinical medicinePhlegmonCrohn Diseasesmall bowelIntestine SmallPreoperative CaremedicineHumansEndoscopy Digestive SystemProspective StudiesSurgical treatmentProspective cohort studyCrohn's diseasemagnetic resonance enterographybusiness.industryGastroenterologymedicine.diseaseMagnetic resonance enterographyequipment and suppliesMagnetic Resonance Imagingpreoperative assessmentStenosiscalibration spheresHomogeneousCalibrationFemale030211 gastroenterology & hepatologyRadiologybusinesshuman activities
researchProduct

Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

2014

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…

AdultMalemedicine.medical_specialtyAnterior ChamberScheimpflug principlePupil diameterIrisVergenceDiagnostic Techniques OphthalmologicalPupilAnterior chamber angleNear visionAnterior chamber eyeYoung AdultOpticslcsh:OphthalmologyOphthalmologyPhotographyMedicineHumansskin and connective tissue diseasesPupilaAnterior chamberCâmara anteriorTécnicas medidas equipamentos de mediçãobusiness.industryAccommodation OcularPupilGeneral Medicineeye diseasesOphthalmologyAcomodação ocularlcsh:RE1-994Accommodation ocularTechniques measures measurement equipmentFemalesense organsbusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Prospective randomized comparison of short-access mother-baby cholangioscopy versus direct cholangioscopy with ultraslim gastroscopes

2012

Mother-baby technologies, the criterion standard for cholangioscopy, have several limitations. A novel, short-access, mother-baby (SAMBA) system may improve this technique. Direct cholangioscopy (DC) was recently developed as an alternative to mother-baby cholangioscopy.Comparison of success rates with SAMBA and DC.Single-center, randomized, controlled trial.Academic tertiary-care referral center.Sixty patients with suspected cholangiopathies randomized to either SAMBA (n = 30) or DC (n = 30).Cholangioscopy under deep sedation.Technical success rate of diagnostic or therapeutic procedure.A total of 24 and 21 diagnostic procedures were performed in the SAMBA and DC groups, respectively. Ther…

AdultMalemedicine.medical_specialtyBiopsySedationTechnical successBile Duct DiseasesConstriction Pathologiclaw.inventionYoung AdultRandomized controlled triallawmedicineHumansDuodenoscopesRadiology Nuclear Medicine and imagingEndoscopy Digestive SystemProspective StudiesAgedAged 80 and overmedicine.diagnostic_testbusiness.industryGastroenterologySmall sampleEquipment DesignMiddle AgedSurgeryEndoscopyBile Duct NeoplasmsReferral centerFemaleGastroscopesmedicine.symptomCRITERION STANDARDbusinessGastroscopesGastrointestinal Endoscopy
researchProduct

Case study: effect of handrim diameter on performance in a paralympic wheelchair athlete.

2009

This study, with a top T-52 class athlete, determines the relationship between stroke frequency (SF) and push time (PT) and wheelchair velocity (Wv) using different handrim diameters (HD) and the effect of different HDs on the athlete’s heart rate (HR) and blood lactate (LACT) at competition speeds. Wv shows a linear-direct relationship with SF but a linear-inverse relationship with PT (p < .001 in both cases). Using bigger handrims (0.37 m instead of 0.36 m), SF increases 6%, while PT decreases 27% (at 24 Km·h–1). HR (p < .0001) increases with Wv and is also affected by HD with differences between the 0.34 m—0.36 m handrim group (lower values) and the 0.37 m handrim (higher values). …

AdultMalemedicine.medical_specialtyCompetitive BehaviorInjury controlPoison controlPhysical Therapy Sports Therapy and RehabilitationMotor ActivityQuadriplegiaWheelchairAnimal scienceCharcot-Marie-Tooth DiseaseHeart RateAssistive technologyHeart rateTask Performance and AnalysisBlood lactatemedicineHumansDisabled PersonsMotor activitybusiness.industryStroke frequencyEquipment DesignBiomechanical PhenomenaWheelchairsPhysical therapybusinessSportsAdapted physical activity quarterly : APAQ
researchProduct

Subfascial Endoscopic Perforator Surgery With Tumescent Local Anesthesia

2002

background. Subfascial endoscopic perforator surgery (SEPS) has become an established procedure. objective. To evaluate SEPS with tumescent local anesthesia (TLA) using an single-port device originally designed for that purpose. methods. Patients selected for SEPS received subcutaneous infiltration of TLA into the medial aspect of the calf 20 minutes before surgery. Bipolar coagulation and dissection were used to treat incompetent perforators. results. Fifty-one patients with 67 legs of CEAP stages C3–C6 underwent SEPS with TLA. In 40 patients or 53 legs (79.1%) TLA alone allowed successful completion of the SEPS procedure. Five patients with 7 legs (10.4%) required additional intravenous a…

AdultMalemedicine.medical_specialtyConscious SedationSuccessful completionDermatologyVaricose UlcerPain controlmedicineHumansLocal anesthesiaIn patientAgedEndoscopesLegVascular diseasebusiness.industryEquipment DesignGeneral MedicineMiddle AgedIncompetent perforatorsmedicine.diseaseSurgerybody regionsTreatment OutcomeVenous InsufficiencyAnesthesiaFemaleSurgeryVenous diseasebusinessVascular Surgical ProceduresBipolar coagulationAnesthesia LocalDermatologic Surgery
researchProduct

Effect of custom-made and prefabricated insoles on plantar loading parameters during running with and without fatigue.

2014

Controversy exists whether custom-made insoles are more effective in reducing plantar loading compared to prefabricated insoles. Forty recreational athletes ran using custom-made, prefabricated, and the original insoles of their running shoes, at rest and after a fatigue run. Contact time, stride rate, and plantar loading parameters were measured. Neither the insole conditions nor the fatigue state modified contact time and stride rate. Addressing prevention of running injuries, post-fatigue loading values are of great interest. Custom-made insoles reduced the post-fatigue loading under the hallux (92 vs. 130 kPa, P0.05), medial midfoot (70 vs. 105 kPa, P0.01), and lateral midfoot (62 vs 96…

AdultMalemedicine.medical_specialtyContact timeRestSTRIDEPhysical Therapy Sports Therapy and RehabilitationRunningSports EquipmentPhysical medicine and rehabilitationPressureMedicineHumansOrthopedics and Sports MedicineFoot OrthosesFatiguebusiness.industryRunning injuriesFootEquipment DesignShoesGait analysisAthletic InjuriesFemaleStress MechanicalbusinessJournal of sports sciences
researchProduct

Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: resu…

1999

Whether the safety and efficacy of implantable cardioverter defibrillator (ICD) therapy can be assured with lower output devices is an important question. The purpose of this study was to evaluate whether programming the device output at twice the augmented defibrillation threshold was as safe and effective as using the maximum energy. Patients indicated for ICD therapy, but without slow monomorphic ventricular tachycardia (MVT), who achieved an augmented defibrillation threshold (DFT plus)or = 15 joules (J) with a single endocardial lead system and a biphasic defibrillator were included in the study. Prior to ICD implantation, patients were randomized into 2 groups. The shock energies in t…

AdultMalemedicine.medical_specialtyDefibrillationTest groupmedicine.medical_treatmentImplantable defibrillatorDefibrillation thresholdElectrocardiographyLow energyInternal medicineMedicineHumansProspective StudiesAgedEjection fractionEquipment Safetybusiness.industryMiddle AgedImplantable cardioverter-defibrillatorDefibrillators ImplantableSurvival RateTreatment OutcomeShock (circulatory)Ventricular FibrillationCardiologyTachycardia VentricularFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessSoftwareThe American journal of cardiology
researchProduct