Search results for "Estenosi"
showing 10 items of 86 documents
Bioresorbable vascular scaffold versus everolimus-eluting stents or drug eluting balloon for the treatment of coronary in-stent restenosis: 1-Year fo…
2017
Objectives to compare the 1-year outcome between bioresorbable vascular scaffold (BVS), everolimus-eluting stent (EES), and drug-eluting balloon (DEB) for in-stent restenosis (ISR) treatment. Background BVS has been proposed as alternative for ISR treatment. To date a direct comparison between BVS and DES or DEB for ISR treatment is lacking. Methods We retrospectively analyzed all ISR lesions treated with BVS, DEB, and EES from January 2012 to December 2014. A total of 548 lesions (498 patients) were included. By applying two propensity-score matching, 93 lesions treated with BVS were compared with 93 lesions treated with DEB, and 100 lesions treated with BVS were compared to 100 lesions tr…
Fludarabine prevents smooth muscle proliferation in vitro and neointimal hyperplasia in vivo through specific inhibition of STAT-1 activation.
2007
Drug-eluting stents are increasingly used to reduce in-stent restenosis and adverse cardiac events after percutaneous coronary interventions. However, the race for the ideal drug-eluting stent is still on, with special regard to the best stent-coating system and the most effective and less toxic drug. Fludarabine, a nucleoside analog, has both anti-inflammatory and antiproliferative cellular effects. The aim of the present study was to assess the cellular and molecular effects of fludarabine on vascular smooth muscle cell (VSMC) growth in vitro and in vivo and the feasibility and efficacy of a fludarabine-eluting stent. To study the biomolecular effects of fludarabine on VSMC proliferation…
Peripheral atherosclerosis is associated with the occurrence of restenosis after percutaneous coronary intervention
2007
The aim of our study was to evaluate, in patients with proven coronary artery disease (CAD) and treated with elective percutaneous coronary intervention (PCI), whether the coexistence of asymptomatic carotid and femoral atherosclerotic lesions would provide prognostic information in terms of occurrence of restenosis.We studied 104 patients with CAD (M/F=77/27), mean age 60.5+/-9 years. All patients were treated with elective PCI. After PCI the suspicion of restenosis was confirmed by coronary angiography. All patients underwent ultrasound duplex scan of carotid and femoral-popliteal-tibial axis to detect atherosclerotic lesions. According to ultrasound results, patients were classified as n…
Diagnostic accuracy of 64-slice CT in the assessment of coronary stents
2007
PURPOSE: The purpose of this study was to assess the diagnostic accuracy of 64-slice computed tomography (64-CT) coronary angiography in the detection of coronary in-stent restenosis. MATERIALS AND METHODS: Ninety-five patients (72 men and 23 women, mean age 58+/-8 years) with previous percutaneous coronary intervention with stenting and suspected restenosis underwent 64-CT (Sensation 64, Siemens). The mean time between stent deployment and 64-CT was 6.1+/-4.2 months. The scan parameters were: slices 32 x 2, individual detector width 0.6 mm, rotation time 0.33 s, feed 3.84 mm/rotation, 120 kV, 900 mAs. After the intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml,…
Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography
2008
BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…
Results of intracoronary stents for management of coronary dissection after balloon angioplasty.
1991
Dissections after coronary balloon angioplasty are risk factors for acute or subacute vessel closures. Intracoronary stenting was developed to avoid these complications by pressing the intimal and medial flaps against the vessel wall, thus reducing the risk of acute thrombosis. A total of 22 stents were implanted into the coronary arteries of 15 patients with dissections after balloon angioplasty causing angina pectoris or ischemic electrocardiographic changes. Stent delivery was successful in all cases. In 1 patient acute stent thrombosis was documented and treated successfully by thrombolytic therapy. Another patient underwent coronary artery bypass surgery 24 hours later because of persi…
Comparison of myocardial perfusion reserve before and after coronary balloon predilatation and after stent implantation in patients with postangiopla…
1996
Background Stents provide a scaffold for coronary arteries after angioplasty and inhibit elastic recoil. Methods and Results In 25 patients with postangioplasty restenosis of the left anterior descending artery, ECG-gated digital subtraction coronary angiograms were recorded at baseline and during hyperemia (12 mg papaverine IC) before and after balloon predilatation (PTCA), after implantation of a Palmaz-Schatz stent, and after 6 months. Densitometric evaluation revealed different time and density parameters to calculate two definitions of myocardial perfusion reserve (MPR1 and MPR2) and maximum flow ratio (MaxFR). Poststenotic MPR1 increased from 1.57±0.14 to 2.59±0.86 after PTCA and to …
Impact of endovascular treatment on clinical status and health-related quality of life.
2008
Background and Aims: Investigating the impact of percutaneous transluminal angioplasty (PTA) on clinical status and health related quality of life in patients with claudication and critical limb ischaemia (CLI). Material and Methods: 61 patients and 64 limbs underwent a primary PTA (30 claudication and 34 CLI cases). Clinical status was graded according to Ahn and Rutherford and ankle/brachial index (ABI). Quality of life was assessed using the Nottingham Health Profile (NHP) preoperatively, one month and one year after the procedure. Triplex scan evaluation of the treated arterial segment was carried out postoperatively and one year after the procedure. Results: Claudication: 24/27 patient…
Physical characterization of alginate-Pluronic F127 gel for endoluminal NABDs delivery
2014
Here we focus the attention on the physical characteristics of a highly biocompatible hydrogel made up of crosslinked alginate and Pluronic F127 (PF127). This is a composite polymeric blend we propose for artery endoluminal delivery of an emerging class of molecules named nucleic acid based drugs (NABDs). The physical characterization of our composite gel, i.e. mesh size distribution and PF127-alginate mutual organization after crosslinking, can significantly determine the NABDs release kinetics. Thus, to explore these aspects, different technical approaches, i.e. rheology, low/high field NMR and TEM, were used. While rheology provided information at the macroscopic and nano-level, the othe…
Beta-3 adrenergic receptor overexpression reverses aortic stenosis-induced heart failure and restores balanced mitochondrial dynamics
2022
25 p.-7 fig.