Role of the bridge in photoinduced electron transfer in porphyrin-fullerene dyads.
2015
The role of π-conjugated molecular bridges in through-space and through-bond electron transfer is studied by comparing two porphyrin-fullerene donor-acceptor (D-A) dyads. One dyad, ZnP-Ph-C60 (ZnP = zinc porphyrin), incorporates a phenyl bridge between D and A and behaves very similarly to analogous dyads studied previously. The second dyad, ZnP-EDOTV-C60, introduces an additional 3,4-ethylenedioxythienylvinylene (EDOTV) unit into the conjugated bridge, which increases the distance between D and A, but, at the same time, provides increased electronic communication between them. Two essential outcomes that result from the introduction of the EDOTV unit in the bridge are as follows: 1) faster…
Inter-observer variability of central corneal thickness measurements using non-contact specular microscopy after laser in situ keratomileusis.
2003
BACKGROUND The aim of this study was to investigate the inter-observer variability of central corneal thickness measurements carried out with a non-contact specular microscope in patients who had undergone myopic laser in situ keratomileusis. METHODS Twenty-six eyes of 26 subjects who had undergone myopic laser in situ keratomileusis were studied with the Topcon SP-2000P non-contact specular microscope (Topcon Corp, Tokyo, Japan). The mean of three consecutive measurements of the central corneal thickness was recorded by two investigators prior to and one month after myopic laser in situ keratomileusis. Results obtained by each of the two physicians were compared. RESULTS Prior to surgery t…
Intraocular pressure measurements during flap preparation using 2 femtosecond lasers and 1 microkeratome in human donor eyes
2012
Purpose To evaluate and compare intraocular pressures (IOPs) during flap preparations performed using 2 femtosecond lasers and a mechanical microkeratome in human donor globes. Setting University Medical Center Mainz, Mainz, and Euroeyes Clinic Stuttgart, Stuttgart, Germany. Design Experimental study. Methods A cannula was inserted through the optic nerve in human globes. The IOP was obtained continuously during flap preparation using the 60 kHz Intralase femtosecond laser, the 200 kHz Visumax femtosecond laser, or the Amadeus II microkeratome. For each experiment, a normal lamellar flap preparation (regular procedure) and a worst-case procedure (femtosecond laser interface was pressed agai…
Comparison of Intraocular Pressure During Corneal Flap Preparation Between a Femtosecond Laser and a Mechanical Microkeratome in Porcine Eyes
2011
To compare the increase in intraocular pressure (IOP) during corneal flap preparation in porcine eyes when using a femtosecond laser or a mechanical microkeratome.The present study was conducted at a university hospital and a private clinic.The vitreous IOP was directly measured with a cannula through the optic nerve in 24 porcine globes (n = 12 for each device). In the first procedure (worst-case procedure), the eye interface was lowered against the globe until abortion of the docking maneuver when using the IntraLase femtosecond laser (Abbott Medical Optics, Santa Ana, CA) or the suction ring was pressed very firmly against the globe when using the Amadeus microkeratome (Ziemer Ophthalmic…
Non-Matrix-Matched Calibration for the Multi-Element Analysis of Geological and Environmental Samples Using 200 nm Femtosecond LA-ICP-MS: A Compariso…
2014
LA-ICP-MS is one of the most promising techniques for in situ analysis of geological and environmental samples. However, there are some limitations with respect to measurement accuracy, in particular for volatile and siderophile/chalcophile elements, when using non-matrix-matched calibration. We therefore investigated matrix-related effects with a new 200 nm femtosecond (fs) laser ablation system (NWRFemto200) using reference materials with different matrices and spot sizes from 10 to 55 μm. We also performed similar experiments with two nanosecond (ns) lasers, a 193 nm excimer (ESI NWR 193) and a 213 nm Nd:YAG (NWR UP-213) laser. The ion intensity of the 200 nm fs laser ablation was much l…
Corneal thickness differences between type 2 diabetes and non-diabetes subjects during preoperative laser surgery examination
2016
Aims To evaluate the differences in corneal thickness between type 2 diabetes subjects with HbA1c under 7.0% and non-diabetes subjects during their preoperative laser surgery examinations. Methods The mean of five consecutive corneal thickness measurements at the central and mid-peripheral cornea was obtained by means of noncontact scanning-slit corneal topography (Orbscan Topography System II; Orbscan, Inc., Salt Lake City, UT, USA) in 35 myopic non-insulin dependent type 2 diabetes subjects (17 males and 18 females) and 48 healthy myopic controls (23 males and 25 females). Results The corneal thickness values at the central and mid-peripheral cornea were significantly higher in the diabet…
Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.
2008
Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …
Incisional Keratotomy to Toric Intraocular Lenses: An Overview of the Correction of Astigmatism in Cataract and Refractive Surgery
2003
In situobservation of the generation and annealing kinetics of E ′ centres induced in amorphous SiO2by 4.7 eV laser irradiation
2011
The kinetics of E' centers induced in silica by 4.7eV laser irradiation was investigated observing in situ their optical absorption band at 5.8 eV. After exposure the defects decay due to reaction with diffusing molecular hydrogen of radiolytic origin. Hydrogen-related annealing is active also during exposure and competes with the photo-induced generation of the centers until a saturation is reached. The concentrations of E' and H2 at saturation are proportional, so indicating that the UV-induced generation processes of the two species are correlated. These results are consistent with a model in which E' and hydrogen are generated from a common precursor Si-H.
Zn(II)-coordination and fluorescence studies of a new polyazamacrocycle incorporating 1H-pyrazole and naphthalene units.
2010
The synthesis and Zn(2+) coordination properties of a new macrocycle (L1) obtained by dipodal (2 + 2) condensation of the polyamine 3-(naphthalen-2-ylmethyl)pentane-1,5-diamine with 1H-pyrazole-3,5-dicarbaldehyde are reported. pH-metric studies show that L1 bears five measurable protonation steps in the 2.0-11.0 pH range. Fluorescence emission studies indicate that the removal of the first proton from the H(5)L1(5+) species leads to a significant decrease in the emission due to a photoinduced electron transfer process. Addition of Zn(2+) promotes a boat-like conformation that approaches both fluorophores and facilitates the formation of an excimer which reaches its highest emission for a 1 …