Search results for "Exercise"

showing 10 items of 3151 documents

Multi-channel electromyography during maximal isometric and dynamic contractions.

2013

Motor unit behavior differs between contraction types at submaximal contraction levels, however is challenging to study during maximal voluntary contractions (MVCs). With multi-channel surface electromyography (sEMG), mean physiological characteristics of the active motor units can be extracted. Two 8-electrode sEMG arrays were attached on biceps brachii muscle (one on each head) to examine behavior of sEMG variables during isometric, eccentric and concentric MVCs of elbow flexors in 36 volunteers. On average, isometric (364 ± 88N) and eccentric (353 ± 74N) MVCs were higher than concentric (290 ± 73N) MVC (p0.001). Mean muscle fiber conduction velocity (CV) was highest during eccentric MVC …

AdultMalemedicine.medical_specialtyContraction (grammar)ElbowPhysical ExertionBiophysicsNeuroscience (miscellaneous)Action PotentialsIsometric exerciseElectromyographyConcentricPhysical medicine and rehabilitationmedicineEccentricHumansmultichannel EMG; dynamic contractions; isometric contractionsdynamic contractionsta315Muscle SkeletalMathematicsisometric contractionsmedicine.diagnostic_testElectromyographyMotor controlAnatomyMotor unitmedicine.anatomical_structuremultichannel EMGPhysical EnduranceNeurology (clinical)Muscle ContractionJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

Neuromuscular Fatigue Following Isometric Contractions with Similar Torque Time Integral

2014

International audience; Torque time integral (TTI) is the combination of intensity and duration of a contraction. The aim of this study was to compare neuromuscular alterations following different isometric sub-maximal contractions of the knee extensor muscles but with similar TTI. Sixteen participants performed 3 sustained contractions at different intensities (25 %, 50 %, and 75 % of Maximal Voluntary Contraction (MVC) torque) with different durations (68.5 +/- 33.4 s, 35.1 +/- 16.8 s and 24.8 +/- 12.9 s, respectively) but similar TTI value. MVC torque, maximal voluntary activation level (VAL), M-wave characteristics and potentiated doublet amplitude were assessed before and immediately a…

AdultMalemedicine.medical_specialtyContraction (grammar)Knee Jointmotor unitsload typehuman skeletal-musclePhysical Therapy Sports Therapy and RehabilitationIsometric exerciseElectromyographyisometric contractionQuadriceps MuscleEMG activityknee extensor musclesYoung AdultInternal medicineHumansMedicineTorqueOrthopedics and Sports Medicineintermittent electrical-stimulationvoluntaryMuscle SkeletalMuscle fatiguemedicine.diagnostic_testdiffersElectromyographybusiness.industry[ SDV.MHEP.PHY ] Life Sciences [q-bio]/Human health and pathology/Tissues and Organs [q-bio.TO]voluntary activationAnatomyPeripheralTorqueNeuromuscular fatiguerecruitmentMuscle FatigueCardiologysustained submaximal contractionsbiceps-brachiiactivationTime integralbusinesspercutaneous neurostimulation
researchProduct

Impaired action potential conduction at high force levels after eccentric exercise

2010

High-density surface electromyography was used to examine whether gross sarcolemmal function is impaired in m. biceps brachii after intensive eccentric elbow flexor exercise, when measured at wide range of isometric contraction levels. Root mean square (RMS), mean power frequency (MNF) and mean muscle fibre conduction velocity (CV) were calculated before and up to four days post-exercise. Maximal isometric voluntary (MVC) force decreased by 21.3+/-5.6% two hours after exercise, and by 12.6+/-11.1% two days post-exercise. CV and MNF decreased both during MVC (CV from 4.1+/-0.3m/s to 3.8+/-0.4m/s and MNF from 92.6+/-10 Hz to 85.2+/-11 Hz) and during electrically evoked maximal M-wave (CV from…

AdultMalemedicine.medical_specialtyContraction (grammar)Physical ExertionNeural ConductionBiophysicsNeuroscience (miscellaneous)Action PotentialsIsometric exerciseElectromyographyBicepsRoot mean square03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansEccentricMuscle Skeletalmedicine.diagnostic_testMuscle fatigueChemistry030229 sport sciencesAnatomyMuscle FatiguePhysical EnduranceCardiologyFemaleStress MechanicalNeurology (clinical)medicine.symptom030217 neurology & neurosurgeryMuscle ContractionMuscle contractionJournal of Electromyography and Kinesiology
researchProduct

Progressive versus rapid rate of contraction during 7 wk of isometric resistance training.

2001

The aim of this study was to compare the effects of isometric training performed with progressive versus rapid rate of contraction on the knee extensor neuromuscular properties over a 7-wk period.Sixteen healthy male subjects trained quadriceps femoris muscle in a leg extension machine three times a week during 7 wk. The training sessions consisted of six sets of six maximal isometric contractions. A first group trained by performing progressive contractions lasting 4 s, whereas a second group performed contractions with a rapid rate of contraction (i.e., ballistic contractions) lasting about 1 s.Both groups significantly increased the isometric and isokinetic voluntary torque, and the resp…

AdultMalemedicine.medical_specialtyContraction (grammar)Physical Therapy Sports Therapy and RehabilitationIsometric exerciseElectromyographyContractilityInternal medicineIsometric ContractionmedicineHumansOrthopedics and Sports MedicineKneeNervous System Physiological PhenomenaMuscle SkeletalExercisePhysical Education and TrainingRapid ratemedicine.diagnostic_testbusiness.industryElectromyographyResistance trainingElectrophysiologyKineticsTorqueCardiologyPhysical therapybusinessMedicine and science in sports and exercise
researchProduct

Biceps brachii muscle oxygenation in electrical muscle stimulation

2010

The purpose of this study was to compare between electrical muscle stimulation (EMS) and maximal voluntary (VOL) isometric contractions of the elbow flexors for changes in biceps brachii muscle oxygenation (tissue oxygenation index, TOI) and haemodynamics (total haemoglobin volume, tHb = oxygenated-Hb + deoxygenated-Hb) determined by near-infrared spectroscopy (NIRS). The biceps brachii muscle of 10 healthy men (23-39 years) was electrically stimulated at high frequency (75 Hz) via surface electrodes to evoke 50 intermittent (4-s contraction, 15-s relaxation) isometric contractions at maximum tolerated current level (EMS session). The contralateral arm performed 50 intermittent (4-s contrac…

AdultMalemedicine.medical_specialtyContraction (grammar)PhysiologyElectrical muscle stimulationmedicine.medical_treatmentElbowHemodynamicsBlood volumeIsometric exerciseOxidative MetabolismBicepsUpper ExtremityHemoglobinsYoung AdultOxygen ConsumptionIsometric ContractionPhysiology (medical)Internal medicineVoluntary ContractionsmedicineHumansMuscle SkeletalSpectroscopy Near-InfraredBlood Volumebusiness.industryNear-Infrared SpectroscopyGeneral MedicineOxygenationAnatomy090300 BIOMEDICAL ENGINEERINGElectric Stimulation111600 MEDICAL PHYSIOLOGYOxygenmedicine.anatomical_structureTorque110600 HUMAN MOVEMENT AND SPORTS SCIENCEOxyhemoglobinsCardiologyNeuromuscular Electrical StimulationbusinessIndraStra Global
researchProduct

Effects of fatigue and recovery on electromyographic and isometric force- and relaxation-time characteristics of human skeletal muscle

1986

Effects of fatigue produced by a maintained 60% isometric loading on electromyographic and isometric force-time and relaxation-time characteristics of human skeletal muscle were studied in 21 males accustomed to strength training. Fatigue loading resulted in a slight but not significant change in the maximal integrated EMG of a maximal isometric contraction, and a large decrease (20.4 +/- 6.3%, p less than 0.001) in maximal force. Fatigue loading increased (p less than 0.05-0.01) neural activation of the muscles during rapidly produced submaximal isometric forces, but had a considerable adverse effect (p less than 0.001) on the corresponding force-time characteristics. Correlations between …

AdultMalemedicine.medical_specialtyContraction (grammar)PhysiologyStrength trainingIsometric exerciseElectromyographyPhysical medicine and rehabilitationIsometric ContractionPhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineForce levelmedicine.diagnostic_testElectromyographyChemistryMusclesPublic Health Environmental and Occupational HealthSkeletal muscleGeneral MedicineKineticsmedicine.anatomical_structureFatigue loadingPhysical EnduranceCardiologymedicine.symptomMuscle ContractionMuscle contractionEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Unchanged H-reflex during a sustained isometric submaximal plantar flexion performed with an EMG biofeedback.

2008

The aim of this study was to assess H-reflex plasticity and activation pattern of the plantar flexors during a sustained contraction where voluntary EMG activity was controlled via an EMG biofeedback. Twelve healthy males (28.0+/-4.8 yr) performed a sustained isometric plantar flexion while instructed to maintain summed EMG root mean square (RMS) of gastrocnemius lateralis (GL) and gastrocnemius medialis (GM) muscles fixed at a target corresponding to 80% maximal voluntary contraction torque via an EMG biofeedback. Transcutaneous electrical stimulation of the posterior tibial nerve was evoked during the contraction to obtain the maximal H-reflex amplitude to maximal M-wave amplitude ratio (…

AdultMalemedicine.medical_specialtyContraction (grammar)Posterior tibial nervePhysical Exertion/physiologyPhysical ExertionBiophysicsNeuroscience (miscellaneous)Isometric exercisePlantar flexionActivation patternFoot/physiologyH-Reflexddc:616.9802Physical medicine and rehabilitationIsometric ContractionMedicineHumansEmg biofeedbackIsometric Contraction/physiologyMuscle SkeletalBiofeedback Psychology/methodsbusiness.industryElectromyographyFootBiofeedback Psychologymusculoskeletal systembody regionsAnesthesiaReflexNeurology (clinical)H-reflexMuscle Skeletal/innervation/physiologybusinessElectromyography/methodsH-Reflex/physiologyJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

Postactivation potentiation in human knee extensors during dynamic passive movements.

2008

Purpose: Postactivation potentiation (PAP), i.e., the increase in twitch torque following a maximal voluntary conditioning contraction, has been shown to depend on muscle contractile conditions (e.g., muscle length). Few studies, however, have investigated the extent of twitch PAP under dynamic conditions in human subjects. Therefore, the aim of the present experiment was to test the twitch PAP during passive dynamic movements following isometric conditioning contractions on nine healthy men. Methods: Maximal twitches were evoked on the knee extensor muscles before and exactly 5 s after a 3-s conditioning maximal voluntary isometric contraction. PAP was determined at a constant joint angle …

AdultMalemedicine.medical_specialtyContraction (grammar)Time FactorsKnee JointMovementPhysical Therapy Sports Therapy and RehabilitationPilot ProjectsIsometric exerciseElectromyographyPassive movementsInternal medicineIsometric ContractionmedicineHumansOrthopedics and Sports MedicineKneeProspective StudiesRange of Motion ArticularMuscle SkeletalKnee extensorsmedicine.diagnostic_testChemistryElectromyographyAnatomyTorqueJoint anglePost activation potentiationCardiologyRange of motionMedicine and science in sports and exercise
researchProduct

Effect of Kinesio Taping and balance exercises on postural control in amateur soccer players: A randomised control trial

2019

The objective of this study was to determine the effect of Kinesio Taping (KT), alone or together with balance exercises (BE), on parameters related to postural control, such as dynamic balance, static balance and flexibility. Forty-four male amateur soccer players (mean age 24.45 (4.79) years) were randomly allocated to 3 groups: KT+BE that received KT and BE (n = 16); KT

AdultMalemedicine.medical_specialtyControl (management)030209 endocrinology & metabolismPhysical Therapy Sports Therapy and RehabilitationPostural controlYoung Adult03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationDouble-Blind MethodSoccermedicineHumansOrthopedics and Sports MedicineDynamic balancePostural BalanceBalance (ability)ProprioceptionFlexibility (personality)030229 sport sciencesProprioceptionBalance exercisesAthletic TapeAthletesPsychologyAmateurJournal of Sports Sciences
researchProduct

Maximal Strength, Muscular Endurance and Inflammatory Biomarkers in Young Adult Men

2014

The aim was to study associations of maximal strength and muscular endurance with inflammatory biomarkers independent of cardiorespiratory fitness in those with and without abdominal obesity. 686 young healthy men participated (25±5 years). Maximal strength was measured via isometric testing using dynamo-meters to determine maximal strength index. Muscular endurance index consisted of push-ups, sit-ups and repeated squats. An indirect cycle ergometer test until exhaustion was used to estimate maximal aerobic capacity (VO2max). Participants were stratified according to those with (102 cm) and those without abdominal obesity (102 cm) based on waist circumference. Inflammatory factors (C-react…

AdultMalemedicine.medical_specialtyCross-sectional studyPhysical Therapy Sports Therapy and RehabilitationIsometric exercise030204 cardiovascular system & hematologyYoung Adult03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicineMuscle Strength030212 general & internal medicineYoung adultAbdominal obesitybiologyInterleukin-6Tumor Necrosis Factor-alphabusiness.industryC-reactive proteinVO2 maxCardiorespiratory fitnessmedicine.diseaseObesityC-Reactive ProteinCross-Sectional StudiesPhysical FitnessObesity AbdominalPhysical EndurancePhysical therapybiology.proteinWaist Circumferencemedicine.symptombusinessBiomarkersInternational Journal of Sports Medicine
researchProduct