Search results for "Exertion"

showing 10 items of 258 documents

Mechanical work and efficiency in treadmill running at aerobic and anaerobic thresholds

1990

Mechanical work, mechanical power, energy consumption and mechanical efficiency were studied in constant-speed treadmill running of 5 min at seven different exercises around aerobic (AerT) and anaerobic (AnT) thresholds. The true efficiency of concentric (positive) mechanical work and gross efficiency of the whole body in seven male subjects were calculated. The total mechanical work was calculated from film through the translational, potential and rotational energy states as the sum of the changes of all the mechanical energy states in all body segments allowing energy transfer between segments and from energy state to state. The total energy consumption was measured by combining aerobic a…

AdultMalemedicine.medical_specialtyAdolescentPhysiologyPhysical ExertionDifferential ThresholdEfficiencyConcentricRunningAnimal sciencemedicineHumansAnaerobiosisTreadmillMechanical energyLegChemistryWork (physics)Energy consumptionAerobiosisBiomechanical PhenomenaRotational energyPhysical therapyRunning economyEnergy MetabolismAnaerobic exerciseActa Physiologica Scandinavica
researchProduct

Reproducibility of aerobic and anaerobic thresholds in 20-50 year old men.

1984

The reproducibility of the aerobic (AerT) and the anaerobic (AnT) threshold was studied in 33 men aged 20–50 years. They completed two maximal exercise tests on a bicycle ergometer. The thresholds, as $$\dot V_{O_2 }$$ (l·min−1), were determined visually by two investigators using both the blood lactate and the respiratory indices. The respiratory variables were measured with a computerized breath-by-breath method; samples of venous blood were drawn every 2nd min and analysed enzymatically for lactate. The reproducibility of the AerT (r=0.94) and of the AnT (r=0.96) were equally good. The AnT can be determined either from blood lactate concentrations (AnTLa) or from ventilatory and gas exch…

AdultMalemedicine.medical_specialtyAgingPhysiologyRestPhysical ExertionDifferential ThresholdPhysical exerciseWork rateIncremental exerciseOxygen ConsumptionHeart RatePhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineAnaerobiosisRespiratory systemReproducibilitybusiness.industryRespirationPublic Health Environmental and Occupational HealthGeneral MedicineVenous bloodMiddle AgedAerobiosisSurgeryMetabolismCardiologyBreathingLactatesbusinessAnaerobic exerciseEuropean journal of applied physiology and occupational physiology
researchProduct

Predictor variables of performance in recreational male long-distance inline skaters.

2011

We investigated the associations between selected anthropometric and training characteristics with race time in 84 recreational male long-distance inline skaters at the longest inline marathon in Europe, the 'Inline One-eleven' over 111 km in Switzerland, using bi- and multivariate analysis. The mean (s) race time was 264 (41) min. The bivariate analysis showed that age (r = 0.30), body mass (r = 0.42), body mass index (r = 0.35), circumference of upper arm (r = 0.32), circumference of thigh (r = 0.29), circumference of calf (r = 0.38), skin-fold of thigh (r = 0.22), skin-fold of calf (r = 0.27), the sum of skin-folds (r = 0.43), percent body fat (r = 0.45), duration per training unit in in…

AdultMalemedicine.medical_specialtyCompetitive BehaviorBODY-COMPOSITIONsportsSWIMMING PERFORMANCEPhysical ExertionPhysical Therapy Sports Therapy and RehabilitationInline skatingSWIMMERSPredictor variables030204 cardiovascular system & hematologyAthletic Performance03 medical and health sciences0302 clinical medicineAnimal scienceMedicineHumansOrthopedics and Sports MedicineBody Weights and MeasuresUltra endurance2. Zero hungerPhysical Education and Trainingbusiness.industry[SCCO.NEUR]Cognitive science/NeuroscienceRACE PERFORMANCEAge Factors030229 sport sciencesStepwise regressionAnthropometryMiddle AgedCircumferenceMARATHON PERFORMANCESurgeryTRAINING VOLUMETIMESkating[ SCCO.NEUR ] Cognitive science/NeuroscienceRUNNERSMultivariate Analysissports.sportBody CompositionRecreationRegression AnalysisUPPER ARMRUNNING PERFORMANCEbusinessBody mass indexJournal of sports sciences
researchProduct

Skeletal muscle fibre types, enzyme activities and physical performance in young males and females

1978

Differences in skeletal muscle characteristics, metabolic profiles and functional performance between males and females were investigated using young (15--24 yrs) male and female twins as subjects. The comparison included such variables as anthropometry, muscle strength, mechanical power, maximum oxygen uptake, electrical activation of muscle, muscle fibre composition (m. vastus lateralis), and activities of several skeletal muscle enzymes. The results disclosed the following primary differences between males and females: In the various functional tests the performance of females was from 61.1 to 84.6% of that in males; distribution of slow twitch fibres in m. vastus lateralis of the female…

AdultMalemedicine.medical_specialtyContraction (grammar)AdolescentPhosphorylasesPhysiologyATPasePhysical ExertionTwinsIsometric exerciseBiologyIsozymeGlycogen phosphorylaseOxygen ConsumptionSex FactorsHeart RatePregnancyHexokinaseInternal medicinemedicineHumansGlycolysisCreatine KinaseAdenosine TriphosphatasesL-Lactate DehydrogenaseMusclesAdenylate KinaseSkeletal muscleVO2 maxIsoenzymesmedicine.anatomical_structureEndocrinologyPhysical FitnessLactatesbiology.proteinFemaleMuscle ContractionActa Physiologica Scandinavica
researchProduct

Multi-channel electromyography during maximal isometric and dynamic contractions.

2013

Motor unit behavior differs between contraction types at submaximal contraction levels, however is challenging to study during maximal voluntary contractions (MVCs). With multi-channel surface electromyography (sEMG), mean physiological characteristics of the active motor units can be extracted. Two 8-electrode sEMG arrays were attached on biceps brachii muscle (one on each head) to examine behavior of sEMG variables during isometric, eccentric and concentric MVCs of elbow flexors in 36 volunteers. On average, isometric (364 ± 88N) and eccentric (353 ± 74N) MVCs were higher than concentric (290 ± 73N) MVC (p0.001). Mean muscle fiber conduction velocity (CV) was highest during eccentric MVC …

AdultMalemedicine.medical_specialtyContraction (grammar)ElbowPhysical ExertionBiophysicsNeuroscience (miscellaneous)Action PotentialsIsometric exerciseElectromyographyConcentricPhysical medicine and rehabilitationmedicineEccentricHumansmultichannel EMG; dynamic contractions; isometric contractionsdynamic contractionsta315Muscle SkeletalMathematicsisometric contractionsmedicine.diagnostic_testElectromyographyMotor controlAnatomyMotor unitmedicine.anatomical_structuremultichannel EMGPhysical EnduranceNeurology (clinical)Muscle ContractionJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

Impaired action potential conduction at high force levels after eccentric exercise

2010

High-density surface electromyography was used to examine whether gross sarcolemmal function is impaired in m. biceps brachii after intensive eccentric elbow flexor exercise, when measured at wide range of isometric contraction levels. Root mean square (RMS), mean power frequency (MNF) and mean muscle fibre conduction velocity (CV) were calculated before and up to four days post-exercise. Maximal isometric voluntary (MVC) force decreased by 21.3+/-5.6% two hours after exercise, and by 12.6+/-11.1% two days post-exercise. CV and MNF decreased both during MVC (CV from 4.1+/-0.3m/s to 3.8+/-0.4m/s and MNF from 92.6+/-10 Hz to 85.2+/-11 Hz) and during electrically evoked maximal M-wave (CV from…

AdultMalemedicine.medical_specialtyContraction (grammar)Physical ExertionNeural ConductionBiophysicsNeuroscience (miscellaneous)Action PotentialsIsometric exerciseElectromyographyBicepsRoot mean square03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansEccentricMuscle Skeletalmedicine.diagnostic_testMuscle fatigueChemistry030229 sport sciencesAnatomyMuscle FatiguePhysical EnduranceCardiologyFemaleStress MechanicalNeurology (clinical)medicine.symptom030217 neurology & neurosurgeryMuscle ContractionMuscle contractionJournal of Electromyography and Kinesiology
researchProduct

Unchanged H-reflex during a sustained isometric submaximal plantar flexion performed with an EMG biofeedback.

2008

The aim of this study was to assess H-reflex plasticity and activation pattern of the plantar flexors during a sustained contraction where voluntary EMG activity was controlled via an EMG biofeedback. Twelve healthy males (28.0+/-4.8 yr) performed a sustained isometric plantar flexion while instructed to maintain summed EMG root mean square (RMS) of gastrocnemius lateralis (GL) and gastrocnemius medialis (GM) muscles fixed at a target corresponding to 80% maximal voluntary contraction torque via an EMG biofeedback. Transcutaneous electrical stimulation of the posterior tibial nerve was evoked during the contraction to obtain the maximal H-reflex amplitude to maximal M-wave amplitude ratio (…

AdultMalemedicine.medical_specialtyContraction (grammar)Posterior tibial nervePhysical Exertion/physiologyPhysical ExertionBiophysicsNeuroscience (miscellaneous)Isometric exercisePlantar flexionActivation patternFoot/physiologyH-Reflexddc:616.9802Physical medicine and rehabilitationIsometric ContractionMedicineHumansEmg biofeedbackIsometric Contraction/physiologyMuscle SkeletalBiofeedback Psychology/methodsbusiness.industryElectromyographyFootBiofeedback Psychologymusculoskeletal systembody regionsAnesthesiaReflexNeurology (clinical)H-reflexMuscle Skeletal/innervation/physiologybusinessElectromyography/methodsH-Reflex/physiologyJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

EMG frequency spectrum, muscle structure, and fatigue during dynamic contractions in man

1979

Fatigue of the vastus lateralis muscle was studied in healthy well-conditioned students, who differed considerable regarding their muscle fibre type distribution. Muscle force decline during repeated maximum voluntary knee extensions at a constant angular velocity (180 degree X s-1 or rad X s-1), using isokinetic equipment, was taken as the criterion for the degree of fatigue. In an attempt to study quantitative as well as qualitative changes in the EMG pattern, integrated EMG (IEMG) and the frequency of the mean power (MPF), computed from the power spectral density function (PSDF), were analysed. It was found that individuals with muscles made up of a high proportion of fast twitch (FT) mu…

AdultMalemedicine.medical_specialtyDynamic contractionsPhysiologyVastus lateralis musclePhysical ExertionAction PotentialsElectromyographyPhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineMuscle fibreFatigueMuscle fatiguemedicine.diagnostic_testElectromyographyChemistryMusclesPublic Health Environmental and Occupational HealthGeneral MedicineAnatomyFrequency spectrumMotor unit recruitmentCardiologymedicine.symptomMuscle ContractionMuscle contractionEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Effects of dynamic exercise and metabolic control on left ventricular performance in insulin-dependent diabetes mellitus

1987

In subclinical diabetic cardiomyopathy, previous reports did not positively correlate the altered cardiac performance with metabolic parameters. Fifteen insulin-dependent diabetic subjects, without any clinical or instrumental evidence of heart diseases, were studied. Signs of diabetic microangiopathy were absent. Systolic time intervals, metabolic and hormonal parameters (blood glucose, free fatty acids, blood lactate and plasma norepinephrine) were evaluated at rest and after dynamic exercise during poor (MAGE 6.36 +/- 0.72 mmol/l) and good (MAGE 3.46 +/- 0.66 mmol/l) metabolic control, obtained by means of insulin therapy. Rest values of systolic time intervals were normal during poor an…

AdultMalemedicine.medical_specialtyEndocrinology Diabetes and Metabolismmedicine.medical_treatmentPhysical ExertionLeft Ventricular Ejection TimeNorepinephrine (medication)EndocrinologyDiabetes mellitusDiabetic cardiomyopathyInternal medicineInternal MedicinemedicineHumansSubclinical infectionbusiness.industryInsulinHemodynamicsHeartGeneral Medicinemedicine.diseaseDiabetes Mellitus Type 1EndocrinologyMetabolic control analysisHeart Function TestsCardiologyFemalebusinessmedicine.drugHormoneActa Diabetologica Latina
researchProduct

Effects of oxygen fraction in inspired air on force production and electromyogram activity during ergometer rowing

1997

Six male rowers rowed maximally for 2500 m in ergometer tests during normoxia (fractional concentration of oxygen in inspired air, F IO2 0.209), in hyperoxia (F IO2 0.622) and in hypoxia (F IO2 0.158) in a randomized single-blind fashion. Oxygen consumption (V˙O2), force production of strokes as well as integrated electromyographs (iEMG) and mean power frequency (MPF) from seven muscles were measured in 500-m intervals. The iEMG signals from individual muscles were summed to represent overall electrical activity of these muscles (sum-iEMG). Maximal force of a stroke (F max) decreased from the 100% pre-exercise maximal value to 67 (SD 12)%, 63 (SD 15)% and 76 (SD 13)% (P<0.05 to normoxia, AN…

AdultMalemedicine.medical_specialtyErgometryPhysiologyPhysical ExertionRowingOxygenechemistry.chemical_elementPhysical exerciseElectromyographyOxygen03 medical and health sciencesOxygen Consumption0302 clinical medicinePhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineLactic Acidcomputer.programming_languageHyperoxiamedicine.diagnostic_testElectromyographyChemistryPublic Health Environmental and Occupational Health030229 sport sciencesGeneral MedicineMean frequencySurgeryOxygenEndocrinologyAnalysis of variancemedicine.symptomcomputer030217 neurology & neurosurgeryEuropean Journal of Applied Physiology
researchProduct