Search results for "Experimental technique"
showing 10 items of 227 documents
Missions to Mars: Characterization of Mars analogue rocks for the International Space Analogue Rockstore (ISAR)
2013
International audience; Instruments for surface missions to extraterrestrial bodies should be cross-calibrated using a common suite of relevant materials. Such work is necessary to improve instrument performance and aids in the interpretation of in-situ measurements. At the CNRS campus in Orléans, the Observatoire des Sciences de l'Univers en région Centre (OSUC) has created a collection of well-characterised rocks and minerals for testing and calibrating instruments to be flown in space missions. The characteristics of the analogue materials are documented in an accompanying online database. In view of the recent and upcoming rover missions to Mars (NASA's 2011 Mars Science Laboratory (MSL…
Neutrino interaction classification with a convolutional neural network in the DUNE far detector
2020
The Deep Underground Neutrino Experiment is a next-generation neutrino oscillation experiment that aims to measure CP-violation in the neutrino sector as part of a wider physics program. A deep learning approach based on a convolutional neural network has been developed to provide highly efficient and pure selections of electron neutrino and muon neutrino charged-current interactions. The electron neutrino (antineutrino) selection efficiency peaks at 90% (94%) and exceeds 85% (90%) for reconstructed neutrino energies between 2–5 GeV. The muon neutrino (antineutrino) event selection is found to have a maximum efficiency of 96% (97%) and exceeds 90% (95%) efficiency for reconstructed neutrino…
Laser resonance ionization spectroscopy on lutetium for the MEDICIS project
2017
The MEDICIS-PROMED Innovative Training Network under the Horizon 2020 EU program aims to establish a network of early stage researchers, involving scientific exchange and active cooperation between leading European research institutions, universities, hospitals, and industry. Primary scientific goal is the purpose of providing and testing novel radioisotopes for nuclear medical imaging and radionuclide therapy. Within a closely linked project at CERN, a dedicated electromagnetic mass separator system is presently under installation for production of innovative radiopharmaceutical isotopes at the new CERN-MEDICIS laboratory, directly adjacent to the existing CERN-ISOLDE radioactive ion beam …
Ramsey technique applied in a Penning trap mass spectrometer
1991
Abstract The Ramsey method has been applied in an experiment aiming for accurate mass determination of unstable isotopes. The ion motion in a Penning trap has been excited with time-separated oscillatory fields and Ramsey fringes were observed in the case of dipole and quadrupole excitation. The experimental resonances are in good agreement with theory. Further applications of the technique are discussed.
The NA48 event-building PC farm
2003
The NA48 experiment at the CERN SPS aims to measure the parameter $\Re(\epsilon'/ \epsilon)$ of direct CP violation in the neutral kaon system with an accuracy of $2 \times 10^{-4}$. Based on the requirements of: \\\\ * high event rates (up to 10 kHz) with negligible dead time;\\ * support for a variety of detectors with very wide variation in the number of readout channels;\\ * data rates of up to 150 MByte/s sustained over the beam burst;\\ * level-3 filtering and remote data logging in the CERN computer center; \\\\ the collaboration has designed and built a modular pipelined data flow system with 40 MHz sampling rate. The architecture combines custom-designed components with commerciall…
A Time Projection Chamber with GEM-Based Readout
2016
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams
1997
Abstract A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 × 10 5 has been achieved. Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.
Advances in surface ion suppression from RILIS: Towards the Time-of-Flight Laser Ion Source (ToF-LIS)
2016
Abstract We present results from the development towards the Time-of-Flight Laser Ion Source (ToF-LIS) aiming for the suppression of isobaric contaminants through fast beam gating. The capability to characterize high resistance ion sources has been successfully demonstrated. A ninefold selectivity gain has been achieved through suppression of surface ionized potassium, while maintaining >90% transmission for laser-ionized gallium using a thin wall graphite ionizer cavity combined with a fast beam gate. Initial results from the investigation of glassy carbon as a potential hot cavity ion source are presented. Power-cycle tests of a newly designed mount for fragile ion source cavities indicat…
Ion traps — recent applications and developments
1991
Abstract Paul and Penning traps are now widely applied in chemistry and physics laboratories. They are used as storage devices, as tools for precision spectroscopy and metrology, and as mass spectrometers. Direct mass measurements of short-lived Rb, Sr, Cs, Ba, Fr and Ra isotopes were performed at the on-line mass separator ISOLDE at CERN, Geneva, by means of a tandem Penning trap system. The ions from ISOLDE are captured and cooled in a first trap and trasnferred to a second trap. Here the mass of the trapped ions is determined by measuring their cyclotron frequency. Resolving powers exceeding m/Δm (FWHM) = 106 could be achieved. Mass values of about 60 isotopes have been determined with a…
Enhancing the extraction of laser-ionized beams from an arc discharge ion source volume
2018
© 2018 The Author(s) The Versatile Arc Discharge and Laser Ion Source (VADLIS) is a recently established ion source for the CERN-ISOLDE radioactive ion beam facility. It offers either electron-impact ionization (VADIS-mode) or resonance laser ionization (RILIS-mode). The choice of operating mode depends on the element of interest or the required beam purity. Particle-in-cell simulations using the VSim software show that the ion extraction efficiency of the VADLIS in RILIS-mode can be improved if it is equipped with an insulated extractor plate, to which an optimal voltage can be applied. This enables optimization of the RILIS-mode ion extraction independently of the electron density. Experi…