Search results for "Extraction"

showing 10 items of 2072 documents

Automatic screening of cardiac disorders using wavelet analysis of heart sound

2017

Body auscultation is a dominant method for physical examination of human heart using conventional stethoscope. This clinical method is non invasive and efficient but it requires a medical expert to interpret the heart sound for assessment of cardiac disorders. This paper presents analysis of heart sounds in wavelet domain for automated screening of cardiac disorders. Heart sound signal is transformed in wavelet domain to find out discrimination between heart sounds recorded from healthy and anomalous patients. Discriminatory features extracted from wavelet coefficients of heart sound are subjected to machine learning for screening of cardiac disorders automatically. The proposed method for …

Sound (medical instrument)Audio signalmedicine.diagnostic_testStethoscopebusiness.industrySpeech recognitionFeature extractionPhysical examinationAuscultationlaw.inventionWaveletlawHeart soundsmedicinebusiness2017 4th IEEE Uttar Pradesh Section International Conference on Electrical, Computer and Electronics (UPCON)
researchProduct

Microphones’ Directivity for the Localization of Sound Sources

2011

In a recent paper [P. Rizzo, G. Bordoni, A. Marzani, and J. Vipperman, "Localization of Sound Sources by Means of Unidirectional Microphones, Meas. Sci. Tech., 20, 055202 (12pp), 2009] the proof-of-concept of an approach for the localization of acoustic sources was presented. The method relies on the use of unidirectional microphones and amplitude-based signals' features to extract information about the direction of the incoming sound. By intersecting the directions identified by a pair of microphones, the position of the emitting source can be identified. In this paper we expand the work presented previously by assessing the effectiveness of the approach for the localization of an acoustic…

Sound localizationunidirectional microphonesound source localization; unidirectional microphones; polar directivity pattern; feature extraction; timedelay estimate.timedelay estimate.Anechoic chamberComputer scienceAcousticsfeature extractionFeature extractionDetectorpolar directivity patternAcoustic source localizationDirectivityExpression (mathematics)sound source localizationPosition (vector)
researchProduct

VIRES: A distributed open architecture for pictorial database

2006

In this paper we describe VIRES (Visual Information Retrieval Extendible System) an open distributed pictorial database for image retrieval. The retrieval methods, pictorial indexing and data are distributed over the network. VIRES has been designed as an open architecture. The system is based on the concept of distributed model via dictionary in order to reach a good versatility without changing the kernel of VIRES.

Space technologyInformation retrievalSettore INF/01 - InformaticaDistributed databaseDatabaseComputer scienceSearch engine indexingFeature extractioncomputer.software_genreDatabase indexKernel (image processing)Control and Systems EngineeringHardware and ArchitectureElectrical and Electronic EngineeringOpen architecturecomputerImage retrieval2003 IEEE International Workshop on Computer Architectures for Machine Perception
researchProduct

Monitoring supercritical fluid extraction by thermal lens spectrometry with pulsed laser excitation

1999

Abstract A dual-beam thermal lens spectrometer (TLS) with a pulse pump–probe coaxial configuration was coupled to commercially available supercritical fluid extraction equipment using a high-pressure flow cell interface. Because of its feasible critical parameters, moderate cost and good thermooptical properties, carbon dioxide was used as supercritical solvent. Using trans -β-carotene as analyte, several factors related with the extraction process under continuos flow conditions were studied in order to establish their influence in the thermal lens signal magnitude. Under the optimum experimental conditions, the relative TLS signal area showed a linear relationship with the concentration o…

SpectrometerChemistryExtraction (chemistry)Supercritical fluid extractionAnalytical chemistryMass spectrometryBiochemistrySupercritical fluidAnalytical Chemistrylaw.inventionLens (optics)lawPhase (matter)Environmental ChemistryCoaxialSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of dithiocarbamates and metabolites in plants by liquid chromatography–mass spectrometry

2004

Abstract A quantitative matrix solid-phase dispersion and liquid chromatography–atmospheric pressure chemical ionization mass spectrometry (LC–APCI–MS) method is outlined for the simultaneous analysis of dithiocarbamates (DTCs) and their degradation products in plants. Compounds analyzed are dazomet, disulfiram, thiram and the metabolites ethylenthiourea and propylenthiourea. The performance of two different sample preparation protocols, the proposed one and other based on solid-phase extraction, as well as, of both atmospheric pressure ionization sources, APCI and electrospray, were compared. The effect of several parameters on the extraction, separation and detection was studied. Dithioca…

Spectrometry Mass Electrospray IonizationChemical ionizationChromatographyChemistryOrganic ChemistryReproducibility of ResultsAtmospheric-pressure chemical ionizationGeneral MedicinePlantsReference StandardsMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)ThiocarbamatesLiquid chromatography–mass spectrometryFruitVegetablesIndicators and ReagentsSample preparationSolid phase extractionChromatography LiquidJournal of Chromatography A
researchProduct

Routine application using single quadrupole liquid chromatography-mass spectrometry to pesticides analysis in citrus fruits.

2005

Abstract A rapid and sensitive liquid chromatography–electrospray ionization–mass spectrometry method has been developed for the routine analysis of buprofezin, bupirimate, hexaflumuron, tebufenpyrad, fluvalinate and pyriproxyfen in citrus fruits. Extracts were obtained by matrix solid-phase dispersion (MSPD) using C 18 as dispersant and dichloromethane-methanol (80:20, v/v) as eluent. Matrix effects were tested for all matrices by addition of standard to sample blank extracts (samples containing no detectable residues). Mean recoveries obtained at fortification levels between 0.01 and 5 mg kg −1 were 57–97% with relative standard deviations (RSDs) from 5 to 19%. The limits of quantificatio…

Spectrometry Mass Electrospray IonizationChromatographyChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineMass spectrometryBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryTriple quadrupole mass spectrometerMatrix (chemical analysis)Liquid chromatography–mass spectrometryFruitmedia_common.cataloged_instanceSample preparationSolid phase extractionEuropean unionPesticidesmedia_commonChromatography LiquidJournal of chromatography. A
researchProduct

Liquid chromatography–electrospray quadrupole ion-trap mass spectrometry of nine pesticides in fruits

2004

A liquid chromatographic method, with electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS), has been developed for determining acrinathrin, carbosulfan, cyproconazole, lambda-cyhalothrin, kresoxim methyl, pyrifenox, pyriproxyfen, propanil, and tebufenpyrad in fruits. The ions prominent in ESI spectra were [M + H]+ and [M + Na]+. In the mass analyzer, collision-induced dissociation fragmentation involved common pathways, for example, product ions of [M + H]+ resulted from the cleavage of the carbamic group or an oxygen bound. The utility of the method is demonstrated by the analysis of crude extracts obtained by matrix solid-phase dispersion (MSPD) using C18 as dispersant and dich…

Spectrometry Mass Electrospray IonizationElectrosprayChromatographyChemistryElectrospray ionizationOrganic ChemistryGeneral MedicineTandem mass spectrometryMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)FruitCalibrationSolid phase extractionIon trapPesticidesChromatography LiquidJournal of Chromatography A
researchProduct

Determination of macrolide antibiotics in meat and fish using pressurized liquid extraction and liquid chromatography–mass spectrometry

2008

We developed a method for determining the quantities of seven macrolide antibiotics in meat and fish by using pressurized liquid extraction (PLE) and liquid chromatography-mass spectrometry with electrospray ionization (LC-(ESI)MS). The PLE was optimized with regard to solvents, temperature, pressure, extraction time and number of cycles. The optimum conditions were: methanol as the extraction solvent; a temperature of 80 degrees C; a pressure of 1500psi; an extraction time of 15min; 2 cycles; a flush volume of 150% and a purge time of 300s. All recoveries for macrolide antibiotics were over 77% at 200mug/kg, except for erythromycin, which was 58%. The repeatability and reproducibility on d…

Spectrometry Mass Electrospray IonizationElectrosprayMeatChromatographySwineChemistryElectrospray ionizationOrganic ChemistryExtraction (chemistry)FishesAnalytic Sample Preparation MethodsAnalytic Sample Preparation MethodsGeneral MedicineMass spectrometryBiochemistryHigh-performance liquid chromatographyDrug ResiduesAnti-Bacterial AgentsAnalytical ChemistryLiquid chromatography–mass spectrometryAnimalsCattleChickensChromatography LiquidAntibacterial agentJournal of Chromatography A
researchProduct

Simultaneous screening and quantification of aminoglycoside antibiotics in honey using mixed-mode liquid chromatography with quadrupole time-of-fligh…

2018

An analytical method based on liquid chromatography with quadrupole time-of-flight mass spectrometry has been developed for the simultaneous determination of six aminoglycoside antibiotics in honey. The sample pretreatment included extraction with aqueous trichloroacetic acid followed by solid-phase extraction on Strata-X polymeric reversed phase cartridges. Liquid chromatography separation was performed on an Obelisc R zwitterionic type mixed-mode column. An ionBooster™ heated electrospray source was used and showed enhanced ionization efficiency in comparison to a conventional electrospray source. The observed signal enhancement ranged from 3- (neomycin) to 16-fold (gentamicin C1). A data…

Spectrometry Mass Electrospray IonizationElectrosprayTime FactorsElectrospray ionizationDrug Evaluation PreclinicalFiltration and Separation02 engineering and technologyMass spectrometry01 natural sciencesMass SpectrometryAnalytical ChemistryIonizationChromatographyChemistry010401 analytical chemistryAminoglycosideExtraction (chemistry)HoneyRepeatability021001 nanoscience & nanotechnologyAnti-Bacterial Agents0104 chemical sciencesAminoglycosidesGentamicin C10210 nano-technologyChromatography LiquidJournal of Separation Science
researchProduct

Development and Validation of a LC-ESI-MS/MS Method for the Determination of Alternaria Toxins Alternariol, Alternariol Methyl-Ether and Tentoxin in …

2016

Alternaria species are capable of producing several secondary toxic metabolites in infected plants and in agricultural commodities, which play important roles in food safety. Alternaria alternata turn out to be the most frequent fungal species invading tomatoes. Alternariol (AOH), alternariol monomethyl ether (AME), and tentoxin (TEN) are some of the main Alternaria mycotoxins that can be found as contaminants in food. In this work, an analytical method based on liquid chromatography (LC) tandem mass spectrometry (MS/MS) detection for the simultaneous quantification of AOH, AME, and TEN in tomato and tomato-based products was developed. Mycotoxin analysis was performed by dispersive liquid-…

Spectrometry Mass Electrospray IonizationHealth Toxicology and MutagenesisAlternariollcsh:MedicineFood ContaminationtomatoToxicologyTandem mass spectrometry01 natural sciencesAlternaria alternataPeptides CyclicArticleMatrix (chemical analysis)chemistry.chemical_compoundLactones0404 agricultural biotechnologySolanum lycopersicumTandem Mass SpectrometryLC-MS/MSdispersive liquid-liquid microextractionMycotoxinDetection limitChromatographybiology010401 analytical chemistrylcsh:RReproducibility of ResultsAlternaria04 agricultural and veterinary sciencesMycotoxinsAlternariabiology.organism_classification040401 food science0104 chemical scienceschemistryTentoxinChromatography Liquid<i>Alternaria</i>; LC-MS/MS; dispersive liquid-liquid microextraction; tomatoToxins; Volume 8; Issue 11; Pages: 328
researchProduct