Search results for "Eye Disease"
showing 10 items of 1572 documents
Preoperative simulation of postoperative iris-fixated phakic intraocular lens position and simulation of aging using high-resolution Scheimpflug imag…
2006
To increase postoperative safety after implantation of iris-fixated phakic intraocular lenses (pIOLs), optimal preoperative evaluation and patient selection is mandatory. We present a new software tool in a high-resolution Scheimpflug imaging device that precisely simulates the postoperative position of an iris-fixated pIOL and also simulates the effect of aging on the pIOL's position.
Goldmann Tonometry After Hyperopic Laser In Situ Keratomileusis
2004
PURPOSE To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/-…
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
2019
ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…
Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes
2003
Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…
Visual-motion suppression in congenital pendular nystagmus.
2009
Patients with a congenital pendular nystagmus are known not to experience oscillopsia in a normal visual environment. The data of a 31-year-old female patient suffering from a congenital pendular nystagmus are presented. The aim of the fluorodeoxyglucose positron emission tomography (FDG-PET) experiment was to analyze the regional cerebral glucose metabolism (rCGM) during minimal as well as maximal nystagmus. Video-oculography showed a maximum in frequency of the horizontal pendular nystagmus during gaze to the left, whereas the zone of minimal nystagmus was 10 degrees to the right. Two sessions with an 18F-fluorodeoxyglucose tracer were performed to analyze cerebral blood-glucose utilizati…
Survival After Transplantation of Corneas From a Rabies-Infected Donor
2011
To examine the tissue samples of 2 corneal recipients from a rabies-infected donor for the presence of rabies to explain their survival.Interventional case series with a review of the literature. The explanted corneal donor buttons were examined via nested reverse transcriptase polymerase chain reaction. The patients were followed up ophthalmologically and neurologically. Antirabies antibodies were measured in blood samples, and skin biopsies were examined by direct fluorescent antibody staining.Two patients received corneas from the same multiorgan donor. Six weeks after transplantation, 3 of the donor's organ recipients became symptomatic and rabies virus was confirmed in tissue from the …
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…
Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.
2013
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…
Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK
2018
ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…