Search results for "Eye Disease"

showing 10 items of 1572 documents

Preoperative simulation of postoperative iris-fixated phakic intraocular lens position and simulation of aging using high-resolution Scheimpflug imag…

2006

To increase postoperative safety after implantation of iris-fixated phakic intraocular lenses (pIOLs), optimal preoperative evaluation and patient selection is mandatory. We present a new software tool in a high-resolution Scheimpflug imaging device that precisely simulates the postoperative position of an iris-fixated pIOL and also simulates the effect of aging on the pIOL's position.

AdultAgingmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentSoftware toolScheimpflug principleIrisHigh resolutionIntraocular lensPhakic intraocular lensPreoperative careImaging Three-DimensionalLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinePreoperative CaremedicineHumansComputer SimulationPostoperative PeriodIris (anatomy)Lens crystallinebusiness.industryeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Goldmann Tonometry After Hyperopic Laser In Situ Keratomileusis

2004

PURPOSE To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/-…

AdultApplanation tonometrymedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SitueducationKeratomileusisGoldmann applanation tonometryTonometry OcularmedicineHumansPostoperative PeriodProspective StudiesIntraocular Pressurebusiness.industrySignificant differenceLASIKhumanitieseye diseasesSurgeryGoldmann tonometryOphthalmologyHyperopiaTreatment OutcomeRetreatmentsense organsbusinessCornea
researchProduct

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

2019

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

AdultBiometryMaterials sciencegenetic structuresContact LensesTomography optical coherenceStatistics Nonparametriclaw.invention03 medical and health sciences0302 clinical medicineOpticslcsh:OphthalmologyOptical coherence tomographyLens thicknessAnterior Eye SegmentReference ValueslawmedicineHumansContact lensesAnalysis of VarianceCross-Over Studiesmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineAxial lengtheye diseasesContact lensLens (optics)Axial Length EyeOphthalmologylcsh:RE1-994Reference values030221 ophthalmology & optometrysense organsTomographybusinessTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes

2003

Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…

AdultBiometryVisual acuityAdolescentLightPseudophakiagenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalEyeRefraction OcularCataractOptical biometryLens Implantation IntraocularHumansMedicineChildAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industryUltrasoundMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOptical axisOphthalmologyInterferometryChild PreschoolOptometrySurgerysense organsmedicine.symptombusinessPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Visual-motion suppression in congenital pendular nystagmus.

2009

Patients with a congenital pendular nystagmus are known not to experience oscillopsia in a normal visual environment. The data of a 31-year-old female patient suffering from a congenital pendular nystagmus are presented. The aim of the fluorodeoxyglucose positron emission tomography (FDG-PET) experiment was to analyze the regional cerebral glucose metabolism (rCGM) during minimal as well as maximal nystagmus. Video-oculography showed a maximum in frequency of the horizontal pendular nystagmus during gaze to the left, whereas the zone of minimal nystagmus was 10 degrees to the right. Two sessions with an 18F-fluorodeoxyglucose tracer were performed to analyze cerebral blood-glucose utilizati…

AdultBlood Glucosemedicine.medical_specialtygenetic structuresVisual AcuityNystagmusAudiologyGeneral Biochemistry Genetics and Molecular BiologyPendular nystagmusOscillopsiaHistory and Philosophy of ScienceFluorodeoxyglucose F18medicineHumansGeneral NeuroscienceGazeMagnetic Resonance Imagingeye diseasesVisual motionFunctional imagingVisual cortexmedicine.anatomical_structurePositron-Emission TomographyFemalemedicine.symptomPsychologyNystagmus CongenitalHorizontal pendular nystagmusAnnals of the New York Academy of Sciences
researchProduct

Survival After Transplantation of Corneas From a Rabies-Infected Donor

2011

To examine the tissue samples of 2 corneal recipients from a rabies-infected donor for the presence of rabies to explain their survival.Interventional case series with a review of the literature. The explanted corneal donor buttons were examined via nested reverse transcriptase polymerase chain reaction. The patients were followed up ophthalmologically and neurologically. Antirabies antibodies were measured in blood samples, and skin biopsies were examined by direct fluorescent antibody staining.Two patients received corneas from the same multiorgan donor. Six weeks after transplantation, 3 of the donor's organ recipients became symptomatic and rabies virus was confirmed in tissue from the …

AdultCentral Nervous SystemMaleReoperationgenetic structuresRabiesmedicine.medical_treatmentMedizinmedicine.disease_causeCorneal TransplantationMedicineHumansRabies transmissionSurvival rateCorneal transplantationbusiness.industryRabies virusMiddle Agedmedicine.diseaseVirologyeye diseasesReverse transcriptaseTissue DonorsTransplantationSurvival RateOphthalmologyRabies virusRNA ViralRabiesFemalesense organsbusiness
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct