Search results for "Eye"

showing 10 items of 2511 documents

Optic Nerve Decompression Improves Hemodynamic Parameters in Papilledema

1993

Purpose: The purpose of this study is to examine changes in color Doppler imaging parameters before and after optic nerve sheath decompression (ONSD) for chronic papilledema caused by pseudotumor cerebri (PTC). Methods: Color Doppler imaging was performed within 48 hours before surgery and within 48 hours after the procedure using a color Doppler unit with a 7.5-MHz phased linear transducer. Pulsed Doppler spectrum analyses were recorded digitally on videotape from the ophthalmic, central retinal, and short posterior ciliary arteries, using a 0.4 × 0.6-mm sample volume. Results: Blood flow velocities in the ophthalmic, short posterior ciliary, and central retinal arteries of 24 eyes were si…

Malemedicine.medical_specialtyCentral retinal arteryVisual acuitygenetic structuresRetinal ArteryPseudotumor cerebriVisual AcuityOphthalmic Arterychemistry.chemical_compoundmedicine.arteryOphthalmologymedicineHumansLongitudinal StudiesPapilledemaUltrasonographyPseudotumor Cerebribusiness.industryCiliary BodyHemodynamicsOptic NerveRetinalArteriesShort posterior ciliary arteriesmedicine.diseaseeye diseasesSurgeryOphthalmologychemistryOphthalmic arteryChronic DiseaseOptic nerveFemalemedicine.symptombusinessBlood Flow VelocityFollow-Up StudiesPapilledemaOphthalmology
researchProduct

Color Doppler Imaging of Arterial Blood Flow in Central Retinal Vein Occlusion

1994

Purpose: The hemodynamics of the retrobulbar arterial circulation of patients with central retinal vein occlusion were evaluated in order to better understand the pathophysiology of this disease. Methods: Color Doppler imaging was used to measure the peak systolic velocity and vascular resistance (pulsatility index) in the retrobulbar arteries of involved eyes and clinically healthy fellow eyes of patients with central retinal vein occlusion and in the control eyes of age- and sex-matched healthy volunteers. Results: Average peak systolic velocity was significantly lower and average vascular resistance was significantly higher in the central retinal artery of involved eyes of patients with …

Malemedicine.medical_specialtyCentral retinal arterygenetic structuresRetinal ArteryHemodynamicsOphthalmic Arterychemistry.chemical_compoundCentral retinal vein occlusionOphthalmologymedicine.arteryRetinal Vein OcclusionmedicineHumansRetrospective StudiesUltrasonographyVascular diseasebusiness.industryCiliary BodyRetinalShort posterior ciliary arteriesAnatomyMiddle Agedmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structurechemistryRegional Blood FlowVascular resistanceFemaleVascular Resistancesense organsbusinessBlood Flow VelocityArteryOphthalmology
researchProduct

Cytokine expression in tears of patients with glaucoma or dry eye disease: A prospective, observational cohort study.

2018

Background: The aim of this study was to assess the expression of cytokines/chemokines in tears from patients with non-advanced primary open-angle glaucoma and patients with non-severe dry eye disease versus healthy controls. Methods: This prospective, observational cohort study enrolled patients with confirmed or suspected non-advanced primary open-angle glaucoma who received any prostaglandin analogue monotherapy for longer than 6 months, patients with non-severe dry eye disease, and healthy controls. Expression of interleukin-1β, interleukin-2, interleukin-4, interleukin-5, interleukin-6, interleukin-8, interleukin-10, and interleukin-12; tumor necrosis factor α; vascular endothelial gro…

Malemedicine.medical_specialtyChemokineGlaucomaInflammationDiseaseCohort Studies03 medical and health sciences0302 clinical medicineOphthalmologymedicineHumansProspective StudiesEye ProteinsAntihypertensive AgentsIntraocular PressureAgedbiologybusiness.industryPreservatives PharmaceuticalCytokine expressionGeneral MedicineMiddle Agedmedicine.diseaseOphthalmologyTears030221 ophthalmology & optometrybiology.proteinTearsCytokinesDry Eye SyndromesFemalemedicine.symptomOphthalmic Solutionsbusiness030217 neurology & neurosurgeryGlaucoma Open-AngleCohort studyEuropean journal of ophthalmology
researchProduct

Effects of multipurpose contact lens solutions on the protein composition of the tear film

2005

Abstract Objectives: To analyze the influence of multipurpose contact lens cleaning solutions on tear proteins. Changes in tear film protein profiles of contact lens wearers who used several marketed brands of multipurpose contact lens care solutions, were assessed by ProteinChip analysis. Methods: Three studies were conducted. Study I was a comparison of Complete and OptiFree multipurpose solutions. Study II was a study with Complete Moisture Plus solution, Study II was a comparison of Renu and Solocare contact lens solutions. Wearers of soft contact lenses were assigned to use the contact lens care solutions for 4 weeks. Non-contact lens wearing patients were used as controls. Tear sample…

Malemedicine.medical_specialtyContact LensesTear proteinslaw.inventionlawOphthalmologymedicineHumansContact lens careEye Proteinsbusiness.industryProtein levelGeneral MedicineProtein compositionMiddle AgedRefractive ErrorsContact lensLens (optics)OphthalmologyContact lens solutionsTearsFemaleContact Lens Solutionssense organsContact lens cleaning solutionsbusinessFollow-Up StudiesOptometryContact Lens and Anterior Eye
researchProduct

Corneal Aberrations in Former Preterm Infants: Results From The Wiesbaden Prematurity Study

2017

Purpose To compare corneal aberrations in former preterm infants to that of full-term infants. Methods A prospective cross-sectional study was carried out measuring the corneal shape with Scheimpflug imaging in former preterm infants of gestational age (GA) ≤32 weeks and full-term infants with GA ≥37 weeks now being aged between 4 to 10 years. The main outcome measures were corneal aberrations including astigmatism (Zernike: Z2-2; Z22), coma (Z3-1; Z31), trefoil (Z3-3; Z33), spherical aberration (Z40) and root-mean square of higher-order aberrations (RMS HOA). Multivariable analysis was performed to assess independent associations of gestational age groups and of retinopathy of prematurity …

Malemedicine.medical_specialtyCorneal Wavefront AberrationScheimpflug principleGestational AgeAstigmatism03 medical and health sciences0302 clinical medicineCorneaOphthalmologymedicineHumansRetinopathy of PrematurityProspective StudiesChildProspective cohort studyComabusiness.industryInfant NewbornCase-control studyGestational ageRetinopathy of prematuritymedicine.diseaseeye diseasesCross-Sectional Studiesmedicine.anatomical_structureCase-Control StudiesChild PreschoolMultivariate Analysis030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessInfant Premature030217 neurology & neurosurgeryInvestigative Opthalmology & Visual Science
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

Optical quality after instillation of eyedrops in dry-eye syndrome

2010

Purpose To study the effect of eyedrop instillation on the optical quality of the air–tear film interface at the anterior cornea in cases of dry eye. Setting University of Valencia, Valencia, Spain. Methods Corneal aberrations (total, spherical-like, and coma-like) were determined from corneal elevation maps and purpose-designed software in cases of dry eye before, immediately after, and 10 minutes after lubricating eyedrop instillation (Blink Intensive Tears). All data were decomposed using Zernike polynomials to yield the root-mean-square wavefront deviations for pupil diameters of 3.0 mm and 5.5 mm. Outcome measures included comparison with clinical tear breakup time (TBUT). Results Wave…

Malemedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersDry Eye SyndromesPupilCorneaCorneaOphthalmologymedicineHumansmedicine.diagnostic_testbusiness.industryAirCorneal TopographyMiddle Agedmedicine.diseaseCorneal topographyeye diseasesSensory SystemsOptical qualityOphthalmologyArtificial tearsmedicine.anatomical_structureTearsTearsDry Eye SyndromesFemaleSurgerysense organsOphthalmic SolutionsbusinessJournal of Cataract and Refractive Surgery
researchProduct

PE-11, a peptide derived from chromogranin B, in the rat eye.

2010

The aim of the study was to investigate the presence and distribution of PE-11, a peptide derived from chromogranin B, in the rat eye. For this purpose, newborn rats were injected with a single dosage of 50mg/kg capsaicin subcutaneously under the neck fold and after three months, particular eye tissues were dissected and the concentration of PE-11-like immunoreactivity was determined by radioimmunoassay. Furthermore, PE-11-like immunoreactivities were characterized in an extract of the rat eye by reversed phase HPLC. Then, the distribution pattern of PE-11 was investigated in the rat eye and rat trigeminal ganglion by immunofluorescence. As a result, PE-11 was present in each tissue of the …

Malemedicine.medical_specialtyCorneal endotheliumgenetic structuresSensory Receptor CellsPhysiologyRadioimmunoassayFluorescent Antibody TechniqueIrisBiologyEyeBiochemistryRetinaCorneaRats Sprague-DawleyCellular and Molecular NeuroscienceTrigeminal ganglionEndocrinologyCiliary bodyNerve FibersInternal medicineCorneamedicineAnimalsChromatography High Pressure LiquidRetinaCiliary BodyOptic Nerveeye diseasesPeptide FragmentsScleraGanglionRatsEndocrinologymedicine.anatomical_structureAnimals NewbornTrigeminal Ganglionsense organsChoroidCapsaicinNeurogliaScleraChromogranin BPeptides
researchProduct

Prospective visual evaluation of apodized diffractive intraocular lenses

2006

To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…

Malemedicine.medical_specialtyDistance visual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologymedicineHumansContrast (vision)In patientProspective StudiesAgedmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesPatient SatisfactionQuality of LifeOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct