Search results for "Eye"
showing 10 items of 2511 documents
Maggot therapy following orbital exenteration
2007
Orbital exenteration is a radical surgery reserved for the treatment of locally invasive or potentially life-threatening orbital tumours.1 Complications occur after 20–25% of exenterations and include tissue necrosis (6%) and infection (3–4%).2–4 In the present report, we describe the management of a post-exenteration orbital infection by the use of maggots. An 82-year-old multimorbid man presented with a fist-sized painless tumour of the left orbit (fig 1A). Computed tomography demonstrated an orbital mass clearly demarcated from the surrounding tissue (fig 1B). After biopsy, the neoplasm was classified as a borderline-malignant extrapleural solitary fibrous tumour. Therefore, a total orbi…
Intravitreal Plasmin Without Associated Vitrectomy as a Treatment for Refractory Diabetic Macular Edema
2009
To determine the effectiveness of a low-dose intravitreal injection of autologous plasmin enzyme (APE), without the performance of a vitrectomy, as a treatment for refractory diffuse diabetic macular edema (DDME).Prospective, comparative, interventional case series.Sixteen patients with bilateral DDME who had not responded to prior laser photocoagulation. All patients received an injection in 1 eye, while the other eye served as a control.Intravitreal 0.2 mL APE injection under topical anesthesia. The APE was obtained using a simplified method.Central macular thickness (CMT) at 1 and 6 months, determined by optical coherence tomography (OCT) and best corrected visual acuity (BCVA).All patie…
Comparison of the influence of corneo-scleral and scleral lenses on ocular surface and tear film metrics in a presbyopic population
2018
PURPOSE: To assess and compare the effect of the corneo-scleral lenses (C-ScL) and scleral lenses (ScL) on tear film parameters and central corneal thickness (CCT) in healthy presbyopic subjects. METHODS: Thirty subjects wore two contact lenses (CLs), randomly assigned, of neutral power, but of different diameters, 12.7mm (C-ScL) and 18mm (ScL) and being equal in the others parameters: material (HS100) and centre thickness (0.29mm). At baseline, 20min after insertion and at 8h, the tear meniscus area (TMA) and CCT was measured (with optical coherence tomography) as well as tear osmolarity. RESULTS: TMA revealed statistical differences for both lenses at 20min (p<0.001), and also at 8h (p=0.…
Geo-Epidemiology of Age-Related Macular Degeneration: New Clues Into the Pathogenesis
2015
Abstract PURPOSE: To evaluate the demographic, geographic, and race-related variables that account for geographic variability in prevalence rates of age-related macular degeneration (AMD). DESIGN: Systematic review, meta-regression, and decision-tree analysis. METHODS: A systematic literature review of PubMed, Medline, Web of Science, and Embase databases identified population-based studies on the prevalence of AMD published before May 2014. Only population-based studies that took place in a spatially explicit geographic area that could be geolocalized, and used retinal photographs and standardized grading classifications, were included. Latitude and longitude data (geolocalization) and the…
Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.
2011
Purpose To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Setting Private practice surgery center, Valencia, Spain. Design Cohort study. Methods Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. Results In the multifocal group, the mean binocular …
Multifocal intraocular lenses for unilateral cataract in children.
2009
Purpose To evaluate the implantation of apodized diffractive multifocal intraocular lenses (IOLs) in children with unilateral cataract. Setting Ophthalmology Service, Hospital Clinico Lozano Blesa, Zaragoza, Spain. Design Prospective clinical study. Methods Five children between 4 and 6 years of age with unilateral cataract had cataract extraction and implantation of an apodized diffractive multifocal IOL (AcrySof Restor SN60D3). Phacoaspiration was accompanied by posterior capsulorhexis followed by an anterior vitrectomy. Uncorrected distance (UDVA), corrected distance (CDVA), and corrected near (CNVA) visual acuities; binocular function using the Worth 4-dot test and the TNO stereotest; a…
Efficacy of systemic administration of riboflavin on a rabbit model of corneal alkali burn
2020
AbstractChanges in the barrier mechanisms in the eye should determine the rational route for the administration and dosage of each drug in the treatment of traumatic injuries and other pathologies. The aim of this study was to examine the efficacy of intra-arterial delivery of 14C-riboflavin (as an “indicator”) and compare it with intravenous and intramuscular administration in an animal model of chemical eye burn. 14C-riboflavin (14C-I) was administered by intra-arterial (carotid artery), intravenous (femoral vein) and intramuscular (femoral muscle) routes. The total radioactivity was determined over 2 h in the plasma and structures of the rabbit’s eyes using a scintillation counter. The r…
ReSTOR® Diffractive versus Array®2 Zonal-progressive Multifocal Intraocular Lens: a Contralateral Comparison
2007
PURPOSE. To evaluate near and distance visual performance after implantation of a diffractive multifocal intraocular lens (MIOL) (AcrySof ReSTOR ® ) or a refractive MIOL (Array ® 2) in bilateral cataract surgery. METHODS. In this prospective, comparative trial, 18 patients with bilateral cataract were selected to have lens surgery with asymmetric MIOL implantation. Eighteen eyes received ReSTOR MIOL and the 18 fellow eyes were implanted with Array 2. Five months after second lens implantation, main postoperative outcomes were uncorrected and distance corrected near visual acuities (VA). Secondary outcomes were distance VA and near acuity with power add, contrast sensitivity with and without…
Prediction Accuracy of a Novel Dynamic Structure-Function Model for Glaucoma Progression
2014
Purpose To assess the prediction accuracy of a novel dynamic structure-function (DSF) model to monitor glaucoma progression. Methods Longitudinal data of paired rim area (RA) and mean sensitivity (MS) from 220 eyes with ocular hypertension or primary open-angle glaucoma enrolled in the Diagnostic Innovations in Glaucoma Study or the African Descent and Glaucoma Evaluation Study were included. Rim area and MS were expressed as percent of mean normal based on an independent dataset of 91 healthy eyes. The DSF model uses centroids as estimates of the current state of the disease and velocity vectors as estimates of direction and rate of change over time. The first three visits were used to pre…
Effect of large positioning holes on capsule fixation of plate-haptic intraocular lenses
2000
Abstract Purpose To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. Setting Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. Methods In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted under standardized conditions by the same surgeon. The IOL position was documented at the end of surgery and by retroillumination on the first day and 5 months postoperatively. The positioning-hole area was evaluated by ultrasound biomicroscopy (50 MHz) 5 months postoperatively. Results One day postoperatively, no IOL in either group was decentered more than 1.0 mm. Aft…