Search results for "Eye"

showing 10 items of 2511 documents

Unconscious response priming during continuous flash suppression.

2017

Continuous flash suppression (CFS) has become a popular tool for studying unconscious processing, but the level at which unconscious processing of visual stimuli occurs under CFS is not clear. Response priming is a robust and well-understood phenomenon, in which the prime stimulus facilitates overt responses to targets if the prime and target are associated with the same response. We used CFS to study unconscious response priming of shape: arrows with left or right orientation served as primes and targets. The prime was presented near the limen of consciousness and each trial was followed by subjective rating of visibility and a forced-choice response concerning the orientation of the prime…

AdultMaleConsciousnessVisionImaging TechniquesCognitive Neurosciencelcsh:MedicineSocial SciencesNeuroimagingResearch and Analysis MethodsFace RecognitionDiagnostic RadiologyYoung AdultCognitionLearning and MemoryOcular SystemMemoryDiagnostic MedicineFunctional Magnetic Resonance ImagingMedicine and Health SciencesHumansPsychologylcsh:ScienceBrain MappingUnconscious PsychologyRadiology and Imaginglcsh:RCognitive PsychologyBiology and Life SciencesPriming (Psychology)Magnetic Resonance ImagingFaceCognitive ScienceEyeslcsh:QFemalePerceptionSensory PerceptionAccess to ConsciousnessAnatomyHeadResearch ArticleNeurosciencePloS one
researchProduct

Neural net classification of REM sleep based on spectral measures as compared to nonlinear measures

2001

In various studies the implementation of nonlinear and nonconventional measures has significantly improved EEG (electroencephalogram) analyses as compared to using conventional parameters alone. A neural network algorithm well approved in our laboratory for the automatic recognition of rapid eye movement (REM) sleep was investigated in this regard. Originally based on a broad range of spectral power inputs, we additionally supplied the nonlinear measures of the largest Lyapunov exponent and correlation dimension as well as the nonconventional stochastic measures of spectral entropy and entropy of amplitudes. No improvement in the detection of REM sleep could be achieved by the inclusion of …

AdultMaleCorrelation dimensionGeneral Computer ScienceEntropySleep REMLyapunov exponentElectroencephalographysymbols.namesakeStatisticsmedicineHumansEntropy (information theory)MathematicsQuantitative Biology::Neurons and Cognitionmedicine.diagnostic_testArtificial neural networkbusiness.industrySpectral entropyEye movementElectroencephalographyPattern recognitionNonlinear systemNonlinear DynamicssymbolsNeural Networks ComputerArtificial intelligencebusinessAlgorithmsBiotechnologyBiological Cybernetics
researchProduct

A Nonlinear Approach to Brain Function: Deterministic Chaos and Sleep EEG

1992

In order to perform a nonlinear dimensional analysis of the sleep electroencephalogram (EEG), we applied an algorithm proposed by Grassberger and Procaccia to calculate the correlation dimension D2 of different sleep stages under Lorazepam medication versus placebo. This correlation dimension characterizes the dynamics of the sleep EEG and it estimates the degrees of freedom of the signal under study. We demonstrate that slow-wave sleep depicts a much smaller dimensionality than light or rapid eye movement (REM) sleep, and that Lorazepam does not alter the EEG's dimensionality except in stage II and REM.

AdultMaleCorrelation dimensionRapid eye movement sleepSleep REMElectroencephalographyLorazepamHippocampusModels BiologicalPhysiology (medical)mental disordersmedicineAnimalsHumansSlow-wave sleepAuditory CortexSleep Stagesmedicine.diagnostic_testbusiness.industryBrainEye movementElectroencephalographyPattern recognitionPlacebo EffectSleep in non-human animalsElectrodes ImplantedCatsSleep StagesNeurology (clinical)Artificial intelligenceSleepbusinessPsychologyNeuroscienceCurse of dimensionalitySleep
researchProduct

Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Cohere…

2016

To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 periph…

AdultMaleDaytimeMaterials sciencegenetic structuresCornea03 medical and health sciences0302 clinical medicineOpticsOptical coherence tomographyCorneamedicineHumansProspective StudiesFourier domainObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryEpithelium CornealReproducibility of ResultsMiddle Agedeye diseasesOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsObserver variationbusiness030217 neurology & neurosurgeryTomography Optical CoherenceBiomedical engineeringCornea
researchProduct

Optical factors influencing the amplitude of accommodation

2017

AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…

AdultMaleDepth of focusmedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresZernike polynomialsAmplitude of accommodationAudiologyRefraction Ocular050105 experimental psychologyYoung Adult03 medical and health sciencessymbols.namesake0302 clinical medicineOpticsAberrometrymedicineHumans0501 psychology and cognitive sciencesSpherical aberrationRetrospective Studiesbusiness.industryAberrometry05 social sciencesAccommodation OcularPupilPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseSubjective refractioneye diseasesAmplitude of accommodationSensory SystemsStatistical modelingSpherical aberrationOphthalmologyAmplitude030221 ophthalmology & optometrysymbolsRegression AnalysisFemalePsychologybusinessAccommodationVision Research
researchProduct

Occular complications following dental local anesthesia

2010

Objective: To determine the frequencyof appearance and the factors most commonlyassociated with ocular complications following dental local anesthesia, also establishing the location and type of anesthesia used. StudyDesign: An indexed search in the Pubmed and Compludoc databases was carried out with the keywords "oral anesthesia", "ocular", "ophthalmologic", "damage", "complications", "injection". We established a limitation that the literature had to have been published after the year 1970. A total of 19 articles were obtained, forming a total sample of 37 patients. The patient's sex, age, nerve anesthetized, type of anesthetic used, ophthalmological complication present, recoverytime, tr…

AdultMaleDiplopiamedicine.medical_specialtyEye Diseasesbusiness.industryAnesthesia Dental:CIENCIAS MÉDICAS [UNESCO]SurgeryOtorhinolaryngologyAnestheticUNESCO::CIENCIAS MÉDICASmedicineHumansFemaleSurgeryLocal anesthesiamedicine.symptomComplicationbusinessGeneral DentistryAnesthesia LocalIntravascular injectionmedicine.drug
researchProduct

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct

Human sleep under the influence of pulsed radiofrequency electromagnetic fields: A polysomnographic study using standardized conditions

1998

To investigate the influence of radiofrequency electromagnetic fields (EMFs) of cellular phone GSM signals on human sleep electroencephalographic (EEG) pattern, all-night polysomnographies of 24 healthy male subjects were recorded, both with and without exposure to a circular polarized EMF (900 MHz, pulsed with a frequency of 217 Hz, pulse width 577 μs, power flux density 0.2 W/m2. Suppression of rapid eye movement (REM) sleep as well as a sleep-inducing effect under field exposure did not reach statistical significance, so that previous results indicating alterations of these sleep parameters could not be replicated. Spectral power analysis also did not reveal any alterations of the EEG rh…

AdultMaleElectromagnetic fieldmedicine.medical_specialtyanimal structuresAdolescentRadio WavesPhysiologyPolysomnographyAcousticsBiophysicsSleep REMElectroencephalographyAudiologyElectromagnetic FieldsmedicineHumansRadiology Nuclear Medicine and imagingBioelectromagneticsPhysicsmedicine.diagnostic_testPulsed radiofrequencyEye movementElectroencephalographyGeneral MedicineSleep in non-human animalsTelephoneEeg rhythmsPower fluxSleepBioelectromagnetics
researchProduct

Effects of Pulsed High-Frequency Electromagnetic Fields on Human Sleep

1996

In the present study we investigated the influence of pulsed high-frequency electromagnetic fields of digital mobile radio telephones on sleep in healthy humans. Besides a hypnotic effect with shortening of sleep onset latency, a REM suppressive effect with reduction of duration and percentage of REM sleep was found. Moreover, spectral analysis revealed qualitative alterations of the EEG signal during REM sleep with an increased spectral power density. Knowing the relevance of REM sleep for adequate information processing in the brain, especially concerning mnestic functions and learning processes, the results emphasize the necessity to carry out further investigations on the interaction of…

AdultMaleElectromagnetic fieldmedicine.medical_specialtymedicine.drug_classPolysomnographymedia_common.quotation_subjectRapid eye movement sleepSleep REMAudiologyElectroencephalographyHypnoticElectromagnetic FieldsRisk FactorsmedicineHumansSpectral analysisBiological Psychiatrymedia_commonmedicine.diagnostic_testDose-Response Relationship RadiationSignal Processing Computer-AssistedCognitionTelephonePsychiatry and Mental healthNeuropsychology and Physiological PsychologySleep StagesSleep onset latencyPsychologyVigilance (psychology)Neuropsychobiology
researchProduct

Two Novel Deletions (Array CGH Findings) in Pigment Dispersion Syndrome

2007

Purpose: We report the first male with pigment dispersion syndrome and a balanced translocation t(10;15)(p11.1;q11.1). Methods: Cytogenetic analyses using Giemsa banding and FISH methods, and array CGH were performed. Results: Array CGH analyses did not show altered DNA sequences in the breakpoints of the translocation, but revealed two novel deletions in 2q22.1 and 18q22.1. Conclusion: We suppose that the coexistence of t(10;15) and pigment dispersion syndrome in our patient is a coincidence. The deletion in 2q22.1, where the gene LRP1B has been located, may play a major role in the dysembryogenesis of the eye and cause the disorder.

AdultMaleEye DiseasesLRP1BG bandingChromosomal translocationBiologyTranslocation GeneticDNA sequencingmedicineHumansPigment Epithelium of EyeGeneIn Situ Hybridization FluorescenceGenetics (clinical)Sequence DeletionGeneticsChromosomes Human Pair 15Chromosomes Human Pair 10BreakpointNucleic Acid Hybridizationmedicine.diseaseMolecular biologyOphthalmologyPediatrics Perinatology and Child HealthPigment dispersion syndromeFish <Actinopterygii>Retinal PigmentsOphthalmic Genetics
researchProduct