Search results for "Eye"
showing 10 items of 2511 documents
Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.
2007
Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…
Inferior altitudinal hemianopia associated with a tumor in the posterior fossa: report of a case
1984
Altitudinal hemianopias may be related to chiasmatic involvement. A case in which horizontal inferior hemianopia is associated with a tumor in the posterior fossa producing a triventricular hydrocephalus is described. The visual field defect is interpreted as a consequence of the pressure by a dilated third ventricle upon the chiasmatic area.
Laser treatment of giant xanthelasma palpebrarum
2013
Xanthelasma palpebrarum is the most common cutaneous xanthoma. It typically presents in middle-aged and older adults, most often around the eyelids. The diagnosis is made clinically. Giant xanthelasmas palpebrarum are xanthelasmas that extensively affect the superior and inferior bilateral eyelids. Many techniques have been put forward for treating these lesions (surgical, laser, and chemical techniques), but we describe our experience in the treatment of giant xanthelasmas by ultrapulsed CO2 laser. Between 2009 and 2012, in the Division of Plastic and Reconstructive Surgery at the University of Palermo, 12 patients with giant xanthelasmas were treated using a CO2 laser. The laser parameter…
Femtosecond laser versus mechanical keratome LASIK for myopia.
2005
To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…
Evaluation of the MGDRx eyebag treatment in young and older subjects with dry eye symptoms
2021
Summary Objectives This study aims to evaluate the relationship between application of the MGDRx thermal eyebag and dry eye signs and symptoms in young and older subjects and to compare the results between the two groups. Methods Thirty young, healthily volunteers between 18 and 31 years of age (23.95 ± 3.94 years) and thirty older subjects between 61 and 90 years of age (77.97 ± 8.11 years) participated in this study. Ocular surface parameters were assessed using the Oculus Keratograph 5 M, following the guidelines of the Tear Film and Ocular Surface Dry Eye Workshop II Diagnostic Methodology report. Only subjects with a positive score on at least one questionnaire and an initial Non-Invas…
The effect of simulated normal and amblyopic higher-order aberrations on visual performance.
2012
Purpose To study the effect of simulated amblyopic and normal higher-order aberrations on visual performance of normal eyes. Methods To assess visual function, an adaptive optics visual simulator was used to compensate volunteers' ocular aberrations and simulate the wavefront aberration patterns found in healthy and amblyopic eyes in 7 healthy individuals. Visual acuity for high (100%), medium (50%), and low (10%) contrast and contrast sensitivity at 10, 20, and 25 cycles per degree (cpd) were measured after simulation of both pattern aberrations. The modulation transfer function and the point spread function were computed based on the aberration data. All measures were taken for 3 and 5.5 …
Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study
2018
Purpose. - To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. Methods. - All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. Results. - We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, an…
The Transversus and Rectus Abdominis Musculoperitoneal (TRAMP) Composite Flap for Vulvovaginal Reconstruction
1996
The transversus and rectus abdominis musculoperitoneal (TRAMP) flap, a novel composite flap supplied by the deep inferior epigastric vessels, was used successfully for partial vulvovaginal reconstruction following anterior and posterior exenteration. The full potential of the TRAMP flap in vulvovaginal reconstruction is being investigated further.
Abscess of the orbit arising 48 h after root canal treatment of a maxillary first molar
2006
Aim To discuss a rare, but severe complication arising following routine root canal treatment. Summary An orbital abscess is reported that occurred following routine root canal treatment. A young, healthy female patient, with no history of chronic paranasal infection had undergone root canal treatment of the right maxillary first molar. On hospital admission, she presented with extensive periorbital swelling and discreet diplopia. Computed tomography imaging identified massive purulent sinusitis and subsequent involvement of the orbit via the inferior and medial orbital wall within 48 h after completion of root canal treatment. Immediate surgical drainage of the maxillary sinus and the or…
Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome
2007
ABSTRACT PURPOSE: To compare the effects on contrast sensitivity of the IntraLase femtosecond laser for flap creation (IntraLASIK) and standard LASIK for myopia. METHODS: Two hundred eyes of 100 consecutive patients underwent LASIK treatment using the VISX S2 laser system. The femtosecond laser (15 kHz IntraLase) was used for flap creation in 100 eyes (50 patients) and a mechanical microkeratome (Carriazo-Barraquer) was used in 100 eyes (50 patients). Best spectacle-corrected contrast sensitivity was measured before and 6 months postoperatively in the IntraLASIK and mechanical LASIK groups. The IntraLASIK and mechanical LASIKinduced changes in contrast sensitivity were compared under photop…