Search results for "Eye"
showing 10 items of 2511 documents
Binding of 11-cis retinaldehyde to the partially purified cellular retinaldehyde binding protein from bovine retinal pigment epithelium.
1987
11-cis retinaldehyde binding analysis was performed on a bovine retinal pigment epithelium preparation of cellular retinaldehyde binding protein (CRALBP), whose purity degree was estimated as 75%. Equilibrium binding studies were carried out measuring the replacement of tritium-labeled with unlabeled 11-cis retinaldehyde at 25 degrees C. Analysis of the experimental data both by a direct curve-fitting procedure utilizing a non linear least square regression analysis and by a conventional Scatchard plot revealed a single non-interacting binding site with an apparent equilibrium constant of 0.9 X 10(-7) M. A binding stoichiometry of approximately 1 mol of 11-cis retinaldehyde/mol of binding p…
Central corneal thickness in mucopolysaccharidosis II and VI.
2010
Objective To describe the ultrasonographically detected central corneal thickness (CCT) in patients with Type II and VI mucopolysaccharidosis (MPS) and its impact on applanation tonometry and glaucoma detection. Methods Twenty-eight patients with MPS (19 MPS II, nine MPS VI) underwent pachymetric investigation of CCT. Additionally, ultrasound measurements of axial length of the globe, slit-lamp evaluation with semiquantitative grading of corneal clouding, applanation tonometry, and assessment of refractive error were performed. Results Median average corneal thickness was 534.5 microm (range, 491.5-579.0 microm) in the MPS II and 547.0 microm (range, 492.5-693.05 microm) in the MPS VI group…
A comparison of the Canon TX-20P™ non-contact tonometer and pachymeter in healthy eyes
2012
Background: The aim of this study was to compare the intraocular pressure (IOP) and the central corneal thickness (CCT) measurements obtained with the Canon TX-20P™ with IOP measured with Goldmann applanation tonometer (GAT) and the CCT measured with ultrasound (US) pachymetry in healthy eyes. Methods: Thirty one healthy voluntary subjects participated in the study, age ranging from 16 to 81 years (mean age 50.9 years). In total 58 eyes were selected for analysis. All measurements were performed by the same examiner. The measurements were taken in the same order in all subjects: Canon IOP and CCT, Goldmann IOP and US CCT. Results: A strong correlation was found between IOP for both CCT comp…
Fuel For Lamps: Organic Residues Preserved in Iron Age Lamps Excavated at the Site of Sahab in Jordan
2017
Five Iron Age ceramic lamps from a tomb at the site of Sahab in the south-eastern part of central Jordan were analysed using gas chromatography – mass spectrometry (GC–MS). The results of this study provide data on the type of fuel used in three of these lamps. The study proposes that animal fat, possibly of ruminant origin, was used in three Early Iron Age II lamps. The material used in the other two Iron Age I lamps could not be determined due to the absence of diagnostic biomarkers. The data obtained from the lamps can be put in conjunction with the archaeological evidence on the availability of domestic animals and, most probably, use of their products at the site of Sahab during the Ir…
Arginine-rich peptides are blockers of VR-1 channels with analgesic activity
2000
Vanilloid receptors (VRs) play a fundamental role in the transduction of peripheral tissue injury and/or inflammation responses. Molecules that antagonize VR channel activity may act as selective and potent analgesics. We report that synthetic arginine-rich hexapeptides block heterologously expressed VR-1 channels with submicromolar efficacy in a weak voltage-dependent manner, consistent with a binding site located near/at the entryway of the aqueous pore. Dynorphins, natural arginine-rich peptides, also blocked VR-1 activity with micromolar affinity. Notably, synthetic and natural arginine-rich peptides attenuated the ocular irritation produced by topical capsaicin application onto the eye…
Enhancer trap infidelity in Drosophila optomotor-blind
2013
Reporter gene activity in enhancer trap lines is often implicitly assumed to mirror quite faithfully the endogenous expression of the "trapped" gene, even though there are numerous examples of enhancer trap infidelity. optomotor-blind (omb) is a 160 kb gene in which 16 independent P-element enhancer trap insertions of three different types have been mapped in a range of more than 60 kb. We have determined the expression pattern of these elements in wing, eye-antennal and leg imaginal discs as well as in the pupal tergites. We noted that one pGawB insertion (omb (P4) ) selectively failed to report parts of the omb pattern even though the missing pattern elements were apparent in all other 15…
Intraocular Telescopic System Design: Optical and Visual Simulation in a Human Eye Model
2016
Purpose. To design an intraocular telescopic system (ITS) for magnifying retinal image and to simulate its optical and visual performance after implantation in a human eye model. Methods. Design and simulation were carried out with a ray-tracing and optical design software. Two different ITS were designed, and their visual performance was simulated using the Liou-Brennan eye model. The difference between the ITS was their lenses’ placement in the eye model and their powers. Ray tracing in both centered and decentered situations was carried out for both ITS while visual Strehl ratio (VSOTF) was computed using custom-made MATLAB code. Results. The results show that between 0.4 and 0.8 mm of d…
Optical Evaluation of New Designs of Multifocal Diffractive Corneal Inlays
2019
[EN] Purpose. To assess the imaging properties of two different designs of a new concept of corneal inlays whose working principle is based on diffraction. Methods. The quality of the retinal images provided by Diffractive Corneal Inlays (DCIs) was evaluated theoretically in comparison with Small Aperture Corneal Inlay (SACI). ZEMAX OpticStudio software was employed for the simulations in an eye model with different pupil diameters (3.0 mm and 4.5 mm). The employed merit functions in the analysis were the Modulation Transfer Function (MTF), the area under the MTF (MTFa), and the Point Spread Function (PSF). Comparison was made with the SACI at different defocus conditions. Results. The bifo…
The Neuroepithelium Disruption Could Generate Autoantibodies against AQP4 and Cause Neuromyelitis Optica and Hydrocephalus
2014
Neuromyelitis optica is an inflammatory disease characterized by neuritis and myelitis of the optic nerve. Its physiopathology is connected with the aquaporin-4 water channel, since antibodies against aquaporin-4 have been found in the cerebrospinal fluid and blood of neuromyelitis optica patients. The seropositivity for aquaporin-4 antibodies is used for the diagnosis of neuromyelitis optica or neuromyelitis optica spectrum disease. On the other hand, aquaporin-4 is expressed in astrocyte feet in the brain-blood barrier and subventricular zones of the brain ventricles. Aquaporin-4 expression is high in cerebrospinal fluid in hydrocephalus. Furthermore, neuroepithelial denudation precedes n…
Inside the Thompson laboratory during the “cerebellar years” and the continuing cerebellar story
2011
This paper is based on the talk by one of the authors (DL) given at the symposium for the retirement of RF Thompson (RF Thompson: A bridge between 20th and 21st century neuroscience). We first make some informal observations of the historical times and research conditions in the Thompson laboratory when the cerebellum was found to play a critical role in eye lid classical conditioning, the "cerebellar years". These conditions influenced our collaborative international program on the phenomenon known as "transfer of training" or "savings". Our research shows that the appearance of "savings" is an artifact of the order of testing, and depends upon the functioning of the contralateral interpos…