Search results for "FAULTS"
showing 10 items of 61 documents
A suitable control technique for fault-tolerant converters in Distributed Generation
2011
The penetration of Distributed Generation (DG) in power systems is deeply changing the existing distribution networks which is becoming a very sophisticated and complex systems incorporating both active (generators) and passive systems (distribution systems, converters and loads). The necessary simplification can be obtained dealing with small networks, namely Micro-Grids, reproducing, in a smaller scale, the structure and the problems of large networks including production, transmission and distribution of the electrical energy. In order to achieve an adequate level of reliability, fault-tolerant operations of micro-grids become very important. This result can be achieved only using power …
Experimental characterization of series arc faults in AC and DC electrical circuits
2014
This paper presents an experimental characterization of the arc fault phenomenon, for both AC and DC systems, focusing the attention on series arcs. The aim of the study is to find some current characteristics, which can be significant for the purpose of arc detection. The arcing current signal is analyzed in both time and frequency domain. For the AC analysis, the test conditions are chosen in accordance with the “unwanted tripping tests” and the “operation inhibition tests” reported in the Standard UL 1699. The DC study is carried out on the currents waveforms acquired during some on-field tests on a PV plant. Starting from the study herein presented, the authors have found that is it pos…
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
Flexible power converters for the fault tolerant operation of Micro-Grids
2010
The progressive penetration level of Distributed Generation (DG) is destined to cause deep changes in the existing distribution networks no longer considered as passive terminations of the whole electrical system. A possible solution is the realization of small networks, namely the Micro-Grids, reproducing in themselves the structure of the main production and distribution of the electrical energy system. In order to gain an adequate reliability level of the microgrids the individuation and the management of the faults with the goal of maintaining the micro-grid operation (fault tolerant operation) is quite important. In the present paper flexible power converters and a companion control al…
SETUP OF VIRTUAL EXPERIMENTS AND CRITICAL ANALYSIS OF CONVENTIONAL THERMOECONOMIC DIAGNOSIS OF MULTIPLE FAULTS IN AIR-CONDENSED ROOFTOP SYSTEMS
2012
The diagnosis of soft faults in vapor compression cooling systems is a crucial activity, since malfunctions may provoke heavy degradation in plant performance and increase the power consumption for space cooling. Among the various Faults Detection and Diagnosis techniques developed over the last two decades, thermoeconomic diagnosis has been playing only a marginal role due to the difficulties encountered when applying the conventional thermoeconomic approaches to vapor compression refrigeration plants. In this paper a critical analysis on capabilities and limits of thermoeconomic diagnosis of refrigeration systems is proposed. The reference plant assumed for this study is a 116 kWc air-con…
Transient Electrical Behaviour of the TF Superconducting Coils of Divertor Tokamak Test Facility During a Fast Discharge
2022
The paper is focused on the electromagnetic analysis of the Toroidal Field (TF) superconducting coils of the Divertor Tokamak Test facility (DTT) when electrical transients occur in the TF coils system: for example, during the operations of the Fast Discharge Units (FDUs) and considering also, the simultaneous occurrence of a fault condition. During the FDU intervention, a transient voltage excitation lasting few microseconds occurs at the TF coil terminals and it electrically stresses the insulations of TF coils itsef. To investigate the voltage distribution across, inside and between different Double Pancakes (DPs) of each TF coil, a lumped parameters circuital model has been developed an…
Multi-temporal tectonic evolution of Capo Granitola and Sciacca foreland transcurrent faults (Sicily channel)
2019
Highlights • Seismic reflection profiles evidence tectonic inversion and active strike-slip faults offshore SW Sicily foreland • Pliocene-Quaternary transpressional inversion of Late Miocene extensional basins • Transpressional fold growth rates were high in Latest Miocene-Pliocene and decreased during Quaternary Joint analysis of high-penetration multi-channel and high-resolution single-channel seismic reflection profiles, calibrated by deep well boreholes, allowed a detailed reconstruction of the Late Miocene to Recent tectonic history of the Capo Granitola and Sciacca fault systems offshore southwestern Sicily. These two fault arrays are part of a regional system of transcurrent faults t…
Sedimentological and tectonic context of Paleoproterozoïque Franceville basin (Gabon) : fluid pressure structures, bitumen and uranium mineralization
2016
Metallogenic deposits within paleproterozoic basins depend on generation and migration of fluids. The aim of this study is to provide a better understanding of tectonic, sedimentological and diagenetic setting of the uranium deposits in the Franceville basin and to characterize hydraulic fracturing impact on fluid migration processes in sandstone reservoirs.Tectonic study define the N180-170° transfer faults, associated with Archean tectonic and the N110-120° longitudinal normal faults. These two fault directions split the Franceville basin into small sub-basins. The longitudinal normal faults are associated with footwall anticlines and hanging wall synclines. The uranium deposits of France…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…
CO2 flux measurements in volcanic areas using the dynamic concentration method: the influence of the soil permeability.
2006
In order to evaluate the influence of soil permeability on soil CO2 flux measurements performed with the dynamic concentration method, several tests were carried out using soils characterized by different permeability values and flow rates. A special device was assembled in the laboratory to create a one-dimensional gas flow through a soil of known permeability. Using the advective-diffusion theory, a physical model to predict soil concentration gradients was also developed. The calculated values of CO2 concentrations at different depths were compared with those measured during the tests and a good agreement was found. Four soils with different gas permeability (3.6 x 10(-2) to 1.23 x 10(2)…