Search results for "FCI"
showing 10 items of 19 documents
Development, Characterization, and Testing of a SiC-Based Material for Flow Channel Inserts in High-Temperature DCLL Blankets
2018
This work has been carried out within the framework of the EUROfusion Consortium. The views and opinions expressed herein do not necessarily reflect those of the European Commission.
Impact of Bacterial Siderophores on Iron Status and Ionome in Pea
2020
National audience; Including more grain legumes in cropping systems is important for the development of agroecological practices and the diversification of protein sources for human and animal consumption. Grain legume yield and quality is impacted by abiotic stresses resulting from fluctuating availabilities in essential nutrients such as iron deficiency chlorosis (IDC). Promoting plant iron nutrition could mitigate IDC that currently impedes legume cultivation in calcareous soils, and increase the iron content of legume seeds and its bioavailability. There is growing evidence that plant microbiota contribute to plant iron nutrition and might account for variations in the sensitivity of pe…
Conserving plant diversity in Europe: outcomes, criticisms and perspectives of the Habitats Directive application in Italy
2016
Habitat Directive is the core strategy of nature conservation in Europe aiming at halting biodiversity loss. In this study the results of the third Italian assessment regarding the conservation status (CS) of plants listed in the Habitat Directive (Flora of community interest—FCI) was presented. Data was collected from several sources related to plant distribution, population data, habitats and pressures. Following the official European procedure, all parameters were evaluated and combined to give the CS of each taxon in each biogeographical region of presence. A comparison between the recent Italian IUCN and Reporting assessments was performed in order to evaluate the consistency between t…
Does the association of therapeutic exercise and supplementation with sucrosomial magnesium improve posture and balance and prevent the risk of new f…
2021
Abstract Background Fracture of the proximal femur is the most feared complication of osteoporosis. Given the numerous physiological functions that magnesium performs in our body, in the literature there is a correlation between osteoporosis and low serum levels of magnesium. Aim Evaluate the incidence of hypomagnesemia in patients with lateral fragility fracture of the proximal femur, the possible correlation between serum magnesium levels and fractures, and the effectiveness of supplementing Sucrosomial® magnesium associated with therapeutic exercise on the outcome of these patients. Methods We divided the study into two parts. In the first part, we assessed the preoperative incidence of …
Structural Health Monitoring Procedure for Composite Structures through the use of Artifcial Neural Networks
2015
In this paper different architectures of Artifcial Neural Networks (ANNs) for structural damage detection are studied. The main objective is to investigate an ANN able to detect and localize damage without any prior knowledge on its characteristics so as to serve as a real-time data processor for Structural Health Monitoring (SHM) systems. Two different architectures are studied: the standard feed-forward Multi Layer Perceptron (MLP) and the Radial Basis Function (RBF) ANNs. The training data are given, in terms of a Damage Index =D, properly defined using a piezoelectric sensor signal output to obtain suitable information on the damage position and dimensions. The electromechanical respons…
Fractal Dimension Logarithmic Differences Method for Low Voltage Series Arc Fault Detection
2021
Series arc faults introduce singularities in the current signal and changes over time. Fractal dimension can be used to characterize the dynamic behaviour of the current signal by providing a degree of signal chaos. This measure of irregularity exhibits changes in signal behaviour that can suitably be used as a basis for series arc fault detection. In this paper, an efficient low voltage series arc fault detection method based on the logarithmic differences of the estimate of the fractal dimension of the current signal using the multiresolution length-based method is presented. The discrete wavelet transform and the hard thresholding denoising with the universal threshold are also used. Exp…
A set of indicators for arc faults detection based on low frequency harmonic analysis
2016
In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Experimental characterization of series arc faults in AC and DC electrical circuits
2014
This paper presents an experimental characterization of the arc fault phenomenon, for both AC and DC systems, focusing the attention on series arcs. The aim of the study is to find some current characteristics, which can be significant for the purpose of arc detection. The arcing current signal is analyzed in both time and frequency domain. For the AC analysis, the test conditions are chosen in accordance with the “unwanted tripping tests” and the “operation inhibition tests” reported in the Standard UL 1699. The DC study is carried out on the currents waveforms acquired during some on-field tests on a PV plant. Starting from the study herein presented, the authors have found that is it pos…
SiC-based sandwich material for Flow Channel Inserts in DCLL blankets: Manufacturing, characterization, corrosion tests
2017
This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014–2018 under grant agreement No 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission.