Search results for "FISICA APLICADA"
showing 10 items of 316 documents
AMADEUS-The acoustic neutrino detection test system of the ANTARES deep-sea neutrino telescope
2011
The AMADEUS (ANTARES Modules for the Acoustic Detection Under the Sea) system which is described in this article aims at the investigation of techniques for acoustic detection of neutrinos in the deep sea. It is integrated into the ANTARES neutrino telescope in the Mediterranean Sea. Its acoustic sensors, installed at water depths between 2050 and 2300 m, employ piezo-electric elements for the broad-band recording of signals with frequencies ranging up to 125 kHz. The typical sensitivity of the sensors is around - 145 dB re 1 V/mu Pa (including preamplifier). Completed in May 2008, AMADEUS consists of six "acoustic clusters", each comprising six acoustic sensors that are arranged at distanc…
Time calibration of the ANTARES neutrino telescope
2011
The ANTARES deep-sea neutrino telescope comprises a three-dimensional array of photomultipliers to detect the Cherenkov light induced by upgoing relativistic charged particles originating from neutrino interactions in the vicinity of the detector. The large scattering length of light in the deep sea facilitates an angular resolution of a few tenths of a degree for neutrino energies exceeding 10 TeV. In order to achieve this optimal performance, the time calibration procedures should ensure a relative time calibration between the photomultipliers at the level of ~1 ns. The methods developed to attain this level of precision are described.
ANTARES: The first undersea neutrino telescope
2011
The ANTARES Neutrino Telescope was completed in May 2008 and is the first operational Neutrino Telescope in the Mediterranean Sea. The main purpose of the detector is to perform neutrino astronomy and the apparatus also offers facilities for marine and Earth sciences. This paper describes the design, the construction and the installation of the telescope in the deep sea, offshore from Toulon in France. An illustration of the detector performance is given. © 2011 Elsevier B.V. All rights reserved.
The ANTARES telescope neutrino alert system
2012
The ANTARES telescope has the capability to detect neutrinos produced in astrophysical transient sources. Potential sources include gamma-ray bursts, core collapse supernovae, and flaring active galactic nuclei. To enhance the sensitivity of ANTARES to such sources, a new detection method based on coincident observations of neutrinos and optical signals has been developed. A fast online muon track reconstruction is used to trigger a network of small automatic optical telescopes. Such alerts are generated for special events, such as two or more neutrinos, coincident in time and direction, or single neutrinos of very high energy.
Organocatalytic Enantioselective Alkylation of Pyrazol-3-ones with Isatin-Derived Ketimines: Stereocontrolled Construction of Vicinal Tetrasubstitute…
2016
A quinine-derived thiourea catalysed the enantioselective addition of 4-substituted pyrazolones to isatin-derived ketimines, providing a variety of aminooxindole-pyrazolone adducts containing congested vicinal tetrasubstituted stereocentres with excellent outcomes (up to 98% yield, >20:1 dr and 98% ee).
Interaction between heterobinuclear molecules and nature of the ground spin state in oximato-bridged [CuIIMII]2 bis-binuclear complexes (M=Cu, Ni, Mn…
1999
[EN] Two new heterobimetallic complexes [Cu(pdmg)Ni(Me-3[12]N-3)(CH3CH2OH)](ClO4)(2)(2) and [Cu(pdmg) Mn(bipy)(2)]-ClO4)(2) . H2O (3) (H(2)pdmg = 3,9-dimethyl-4,8-diazaundeca-3,8-diene-2 10-dione dioxime; Me-3[12]N-3 = 2,4,4-trimethyl-1,5,9-triazacyclododeca-1-ene; bipy = 2,2'-bipyridyl) have been prepared and characterized. The structure of 2 has been determined by single-crystal X-ray diffraction methods. It consists of [Cu(pdmg)Ni(Me-3[12]N-3)(CH3CH2OH)](2+) cations and non-coordinated perchlorate anions. The [Cu(pdmg)(CH3CH2OH)] complex coordinates to the [Ni(Me-3[12]N-3)](2+) fragment to afford the binuclear unit doubly-bridged by oximato groups in cis arrangement. The coordination geo…
First results on dark matter annihilation in the Sun using the ANTARES neutrino telescope
2013
A search for high-energy neutrinos coming from the direction of the Sun has been performed using the data recorded by the ANTARES neutrino telescope during 2007 and 2008. The neutrino selection criteria have been chosen to maximize the selection of possible signals produced by the self-annihilation of weakly interacting massive particles accumulated in the centre of the Sun with respect to the atmospheric background. After data unblinding, the number of neutrinos observed towards the Sun was found to be compatible with background expectations. The 90% CL upper limits in terms of spin-dependent and spin-independent WIMP-proton cross-sections are derived and compared to predictions of two sup…
Search for High-energy Neutrinos from Gravitational Wave Event GW151226 and Candidate LVT151012 with ANTARES and IceCube
2017
[EN] The Advanced LIGO observatories detected gravitational waves from two binary black hole mergers during their first observation run (O1). We present a high-energy neutrino follow-up search for the second gravitational wave event, GW151226, as well as for gravitational wave candidate LVT151012. We find two and four neutrino candidates detected by IceCube, and one and zero detected by ANTARES, within +/- 500 s around the respective gravitational wave signals, consistent with the expected background rate. None of these neutrino candidates are found to be directionally coincident with GW151226 or LVT151012. We use nondetection to constrain isotropic-equivalent high-energy neutrino emission …
Responsive and Minimalist App Based on Explainable AI to Assess Palliative Care Needs during Bedside Consultations on Older Patients
2021
[EN] Palliative care is an alternative to standard care for gravely ill patients that has demonstrated many clinical benefits in cost-effective interventions. It is expected to grow in demand soon, so it is necessary to detect those patients who may benefit from these programs using a personalised objective criterion at the correct time. Our goal was to develop a responsive and minimalist web application embedding a 1-year mortality explainable predictive model to assess palliative care at bedside consultation. A 1-year mortality predictive model has been trained. We ranked the input variables and evaluated models with an increasing number of variables. We selected the model with the seven …
Percentile Study of chi Distribution. Application to Response Time Data.
2020
As a continuation of our previous work, where a Maxwell&ndash