Search results for "FN"

showing 10 items of 862 documents

Brain Monitoring Via an Innovative CW-FNIRS System

2015

Functional Near InfraRed Spectroscopy (fNIRS) is an imaging technique mainly devoted to human brain monitoring. It is used as a non-invasive technique, in medical field, in order to measure the oxygen concentration of blood. This because the relatively good transparency of biological materials in the near infrared allows sufficient photon transmission through tissues. Within the so-called fNIRS range (650-900 nm), the main absorbers are blood chromophores, in particular the oxygenated and deoxygenated haemoglobin (HbO2 and Hb, respectively). When two or more wavelengths are used, changes of such chromophores can be computed by employing the modified Beer-Lambert law, thus providing importan…

fnirs continuous wave sipm near infrared spectroscopy brainSettore ING-INF/01 - Elettronica
researchProduct

Design and realization of a portable continuous wave fNIRS

2015

A design and implementation of a portable functional Near InfraRed Spectroscopy embedded system prototype is described. In this theoretical and experimental work, we present an embedded system hosting 64 LED sources and 128 Silicon PhotoMultiplier detectors (SiPM). The elementary part of the structure is a flexible probe “leaf” consisting of 16 SiPMs, 4 couples of LEDs, each operating at two wavelengths, and a temperature sensor. The hardware system is based on an ARM main microcontroller that allows to perform both the switching time of LEDs and the acquisition of the SiPM outputs. The performed preliminary experimental tests achieved very promising results, thus demonstrating the effectiv…

fnirs near infrared spectroscopy sipmSettore ING-INF/01 - Elettronica
researchProduct

Continuous Wave fNIRS with Silicon Photomultiplier

2015

This work is focused on the development of a Continuous Wave (CW) NIRS integrated system with multi-wavelength LED sources between 700 and 950 nm and a Silicon Photomultiplier detector (SiPM) developed by STMicroelectronics. The Signal Noise Rate (SNR), measured placing the LEDs and an SiPM in a direct contact with the surface of a plastic phantom mimicking a real human head, results higher than the calculated minimum, required to detect small variation in the HbO2 and HHb concentration, till a source detector separation (SDS) of 6 cm.

fnirs sipm near infrared spectroscopySettore ING-INF/01 - Elettronica
researchProduct

Free vibrations analysis of cracked variable stiffness composite plates by the eXtended Ritz method

2022

Variable stiffness composite laminates show advantageous structural features related to their enlarged design space. They are attractive candidates for advanced engineering applications where the assessment of static and dynamic behavior and strength in the presence of cracks is often required. In the present work, a single-domain extended Ritz formulation is proposed to study the free vibrations of cracked variable stiffness composite plates. The plate model is based on the first-order shear deformation theory whose primary variable, i.e. displacements and rotations, are approximated via a set of orthogonal polynomial trial functions enriched with a set of special crack functions. These fu…

free vibrationscracked platesX-Ritz methodMechanics of MaterialsVariable stiffness compositesMechanical EngineeringGeneral MathematicsGeneral Materials ScienceSettore ING-IND/04 - Costruzioni E Strutture Aerospazialiextended Ritz methodCivil and Structural EngineeringMechanics of Advanced Materials and Structures
researchProduct

Peak oxygen uptake, ventilatory threshold, and arterial stiffness in adolescents

2018

Purpose To investigate the associations of peak oxygen uptake (V̇ O2peak) and V̇ O2 at ventilatory threshold (V̇ O2 at VT) with arterial stiffness in adolescents. Methods The participants were 55 adolescents (36 girls, 19 boys) aged 16–19 years. Aortic pulse wave velocity (PWVao) and augmentation index (AIx%) were measured by non-invasive oscillometric device from right brachial artery level. V̇ O2peak was directly measured during a maximal ramp test on a cycle ergometer. V̇ O2 at VT was determined using the equivalents for ventilation (V̇ E/V̇ CO2 and V̇ E/V̇ O2). V̇ O2peak and V̇ O2 at VT were normalised for body mass (BM) and lean mass (LM). Data were analysed using linear regression ana…

fyysinen kuntoverisuonitauditcardiorespiratory fitnessnuoretadolescentmaksimaalinen hapenottovascular stiffnessvaltimonkovettumistauti
researchProduct

Microalbuminuria Is Associated With Aortic Stiffness Independently of Creatinine Clearance in Essential Hypertension

2009

hypertension microalbuminuria inflammation aortic stiffness
researchProduct

Interferon therapy: the other face of the medal. Ann Ital Med Int. 2004;19(1):5-7.

2004

ifnInterferon therapy
researchProduct

Effect of vertical loads on lateral response of infilled frames

2004

infilled frames masonry infills vertical load lateral stiffness lateral strength
researchProduct

Efficient ethylene polymerisation catalysis by a cationic benzyl hafnium complex containing pyrrolide-imine ligandsElectronic supplementary informati…

2002

A dibenzyl hafnium(IV) complex containing pyrrolide-imine chelate ligands was synthesized and investigated as an ethylene polymerisation catalyst.

inorganic chemicalschemistryEthylene polymerizationPolymer chemistryCationic polymerizationchemistry.chemical_elementOrganic chemistryChelationGeneral ChemistryImine ligandsHafniumCatalysisJournal of the Chemical Society, Dalton Transactions
researchProduct

La resistenza di interfaccia calcestruzzo poroso-terreni a grana fina per il consolidamento di pendii mediante trincee drenanti profonde

2022

Le trincee drenanti profonde rappresentano uno dei metodi più efficaci per la mitigazione del rischio da frana, in pendii con falda idrica. Esse sono realizzate mediante pannelli o pali secanti. Il riempimento è costituito di calcestruzzo poroso o materiale granulare. Se le trincee sono adeguatamente “innestate” nel terreno stabile e il materiale di riempimento ha sufficiente resistenza e rigidezza come il calcestruzzo poroso, si ha ulteriore in-cremento di resistenza a taglio per effetto shear keys, oltre a quello derivante dalla riduzione delle pressioni in-terstiziali. L’incremento di resistenza è dovuto sia alla resistenza all’interfaccia calcestruzzo–terreni sia a quella intrinseca del…

interface shear strengthPervious concreteSettore ICAR/07 - Geotecnicashear keys effect. Pervious concrete for deep trench drains used to stabilise slopes must simultaneously satisfy many requirements namely adequate hydraulic conductiv-ity adequate shear strength a few days after pour-ing capacity to act as a protective filter for soils in which the drain is installed good resistance to clog-ging and adequate residual hydraulic conductivity. The pervious concrete with appropriated mix-design can effectively satisfy all the abovementioned requirements. If the trenches depth is such that they intersect the sliding surface and if the trenches are adequate-ly "socket" in the layers of stable soil there is a fur-ther increase in shear strength due to the shear keys effect. This latter is in addition to the increase in shear strength resulting from the reduction of inter-stitial pressures that remains the principal scope of the draining trenches. Obviously the increase of shear strength due to the shear keys effect occurs if the trenches are filled with material that have enough strength and stiffness such as the porous concrete. In this case the beneficial effects of the draining trenches on stability are also due to the resistance at the concrete interface of the trench - soils and to the intrinsic resistance of the concrete at the area of the trench intersected by the sliding surface taken into consideration.The increase in resistance due to the shear keys effect can be very significant in relation to the thickness and interspace of the trenches. Results reported in the paper demonstrated that the interface fine grained soil-pervious concrete is higher than the residual shear strength of the soil.
researchProduct