Search results for "FN"
showing 10 items of 862 documents
Brain Monitoring Via an Innovative CW-FNIRS System
2015
Functional Near InfraRed Spectroscopy (fNIRS) is an imaging technique mainly devoted to human brain monitoring. It is used as a non-invasive technique, in medical field, in order to measure the oxygen concentration of blood. This because the relatively good transparency of biological materials in the near infrared allows sufficient photon transmission through tissues. Within the so-called fNIRS range (650-900 nm), the main absorbers are blood chromophores, in particular the oxygenated and deoxygenated haemoglobin (HbO2 and Hb, respectively). When two or more wavelengths are used, changes of such chromophores can be computed by employing the modified Beer-Lambert law, thus providing importan…
Design and realization of a portable continuous wave fNIRS
2015
A design and implementation of a portable functional Near InfraRed Spectroscopy embedded system prototype is described. In this theoretical and experimental work, we present an embedded system hosting 64 LED sources and 128 Silicon PhotoMultiplier detectors (SiPM). The elementary part of the structure is a flexible probe “leaf” consisting of 16 SiPMs, 4 couples of LEDs, each operating at two wavelengths, and a temperature sensor. The hardware system is based on an ARM main microcontroller that allows to perform both the switching time of LEDs and the acquisition of the SiPM outputs. The performed preliminary experimental tests achieved very promising results, thus demonstrating the effectiv…
Continuous Wave fNIRS with Silicon Photomultiplier
2015
This work is focused on the development of a Continuous Wave (CW) NIRS integrated system with multi-wavelength LED sources between 700 and 950 nm and a Silicon Photomultiplier detector (SiPM) developed by STMicroelectronics. The Signal Noise Rate (SNR), measured placing the LEDs and an SiPM in a direct contact with the surface of a plastic phantom mimicking a real human head, results higher than the calculated minimum, required to detect small variation in the HbO2 and HHb concentration, till a source detector separation (SDS) of 6 cm.
Free vibrations analysis of cracked variable stiffness composite plates by the eXtended Ritz method
2022
Variable stiffness composite laminates show advantageous structural features related to their enlarged design space. They are attractive candidates for advanced engineering applications where the assessment of static and dynamic behavior and strength in the presence of cracks is often required. In the present work, a single-domain extended Ritz formulation is proposed to study the free vibrations of cracked variable stiffness composite plates. The plate model is based on the first-order shear deformation theory whose primary variable, i.e. displacements and rotations, are approximated via a set of orthogonal polynomial trial functions enriched with a set of special crack functions. These fu…
Peak oxygen uptake, ventilatory threshold, and arterial stiffness in adolescents
2018
Purpose To investigate the associations of peak oxygen uptake (V̇ O2peak) and V̇ O2 at ventilatory threshold (V̇ O2 at VT) with arterial stiffness in adolescents. Methods The participants were 55 adolescents (36 girls, 19 boys) aged 16–19 years. Aortic pulse wave velocity (PWVao) and augmentation index (AIx%) were measured by non-invasive oscillometric device from right brachial artery level. V̇ O2peak was directly measured during a maximal ramp test on a cycle ergometer. V̇ O2 at VT was determined using the equivalents for ventilation (V̇ E/V̇ CO2 and V̇ E/V̇ O2). V̇ O2peak and V̇ O2 at VT were normalised for body mass (BM) and lean mass (LM). Data were analysed using linear regression ana…
Microalbuminuria Is Associated With Aortic Stiffness Independently of Creatinine Clearance in Essential Hypertension
2009
Interferon therapy: the other face of the medal. Ann Ital Med Int. 2004;19(1):5-7.
2004
Effect of vertical loads on lateral response of infilled frames
2004
Efficient ethylene polymerisation catalysis by a cationic benzyl hafnium complex containing pyrrolide-imine ligandsElectronic supplementary informati…
2002
A dibenzyl hafnium(IV) complex containing pyrrolide-imine chelate ligands was synthesized and investigated as an ethylene polymerisation catalyst.
La resistenza di interfaccia calcestruzzo poroso-terreni a grana fina per il consolidamento di pendii mediante trincee drenanti profonde
2022
Le trincee drenanti profonde rappresentano uno dei metodi più efficaci per la mitigazione del rischio da frana, in pendii con falda idrica. Esse sono realizzate mediante pannelli o pali secanti. Il riempimento è costituito di calcestruzzo poroso o materiale granulare. Se le trincee sono adeguatamente “innestate” nel terreno stabile e il materiale di riempimento ha sufficiente resistenza e rigidezza come il calcestruzzo poroso, si ha ulteriore in-cremento di resistenza a taglio per effetto shear keys, oltre a quello derivante dalla riduzione delle pressioni in-terstiziali. L’incremento di resistenza è dovuto sia alla resistenza all’interfaccia calcestruzzo–terreni sia a quella intrinseca del…