Search results for "FREQUENCY"
showing 10 items of 2158 documents
Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.
2014
Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…
Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.
2013
Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…
Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator
2012
A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.
Superresolved imaging based on wavelength multiplexing of projected unknown speckle patterns
2015
We propose a method for resolution enhancement of a diffraction limited optical system based on the capture of a set of low resolution images. These images are obtained after projection of an ensemble of unknown speckle patterns on top of the high resolution object that is to be imaged. Each speckle pattern is generated by the same thin (and unknown) diffuser, but illuminated with a slightly different wavelength. From the ensemble of low resolution images, we obtain a system of equations that can be solved in an iterative manner that enables reconstruction of the high resolution object. As a result, we also achieve the projected high resolution speckle patterns used for the encoding.
Enhancing spatial resolution in digital holographic microscopy by biprism structured illumination.
2014
A novel and efficient architecture of a structured-illumination digital holographic microscope (DHM) is presented. As the DHM operates at the diffraction limit, its spatial resolution on label-free imaging of transparent samples is improved by illuminating the sample with a structured illumination produced by a Fresnel's biprism. The theoretical analysis of the method forecasts a twofold improvement of the spatial resolution. The proposed method requires only two images to improve the spatial resolution, which eases the process of unmixing the high-resolution components by means of an unknown phase-shift procedure. Numerical modeling and experimental results validate the theoretical finding…
Merits of vision in presence of light scattering using Tiffen ProMist filters
2020
Light scattering caused by Tiffen ProMist photographic filters of various grades at different laser radiation 640 nm, 532 nm and 405 nm was objectively studied and compared. The lack of removal of speckles from the scene of laser radiation scattering did not allow an accurate assessment of the effect of scattering on the decrease in image contrast. Subjective deterioration in visual acuity using various contrast optotypes and contrast sensitivity was assessed by scattering induction using filters up to grade #5. Vision contrast sensitivity diminishes within all studied spatial frequency range 0.5-18 cpd. The degradation of the impact factor to visual acuity without scattering filters when t…
Optical and visual quality comparison of implantable Collamer lens and laser in situ keratomileusis for myopia using an adaptive optics visual simula…
2012
Purpose. To compare optical and visual quality of the implantable Collamer lens (ICL) and laser in situ keratomileusis (LASIK) for myopia. Methods. An adaptive optics visual simulator (CRX1, Imagine Eyes, France) was used to simulate the vision after ICL implantation and LASIK procedure from the wavefront aberration pattern for -3 and -6 D. Monocular visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20, and 25 cycles/degree (cpd) were measured for 3- and 5-mm pupils. Modulation transfer function (MTF) and point spread function (PSF) were calculated for a 5-mm pupil. Results. The ICL showed a MTF near of diffraction-limited MTF, but the post-LASIK of MTF worsened…
Wavefront Recovery: Shack-Hartmann Aberrometry vs PhaseLift Using a Single Binary Amplitude Modulating Mask
2019
We investigate whether a wavefront can be recovered by using a single mask rotated in four different positions. Results show that PhaseLift can recover the wavefront from intensity measurements using such a kind of modulation.
Assessment of ventilatory thresholds from heart rate variability in five incremental treadmill tests in cross country skiers
2014
Incremental treadmill tests are widely used in the field of exercise physiology for the assessment of Ventilatory Thresholds for clinical and sport oriented issues. The assessment of Ventilatory Thresholds (VTs) from Heart Rate Variability (HRV) is a relatively new approach with increasing popularity because it is a non-invasive and economical method. Nevertheless, this has not been used in Cross Country (XC) Skiing, an endurance sport where the knowledge of VTs holds special importance. The purpose of the study was to assess VTs using the data derived from HRV analysis in the five main XC skiing-related techniques, Double Poling (DP), Diagonal Striding (DS), Nordic Walking (NW), V1 Skating…
A Study on the Propagation of Plane Stress Waves across the Thickness of a Plate by the Method of Analytic Continuation in Time
2004
The interaction of plane tension/compression waves propagating within a plate perpendicularly to its surface is considered. The analytic solution is obtained by a modified method of characteristics for the one-dimensional wave equation used in problems on an impact of a rigid body on the surface of a plate. The displacements, velocities, and stresses in the plate are determined by the edge disturbance caused by the initial velocity and the stationary force field of masses of the striker and the plate. The method of analytic continuation in time put forward allows a stress analysis for an arbitrary time interval by using finite expressions. Contrary to a stress analysis in the frequency doma…