Search results for "Faces"
showing 10 items of 3167 documents
Direct Measurement of Focusing Fields in Active Plasma Lenses
2018
Physical review accelerators and beams 21(12), 122801 (2018). doi:10.1103/PhysRevAccelBeams.21.122801
Simulations and measurements of beam loss patterns at the CERN Large Hadron Collider
2014
The CERN Large Hadron Collider (LHC) is designed to collide proton beams of unprecedented energy, in order to extend the frontiers of high-energy particle physics. During the first very successful running period in 2010-2013, the LHC was routinely storing protons at 3.5-4 TeV with a total beam energy of up to 146 MJ, and even higher stored energies are foreseen in the future. This puts extraordinary demands on the control of beam losses. An uncontrolled loss of even a tiny fraction of the beam could cause a superconducting magnet to undergo a transition into a normal-conducting state, or in the worst case cause material damage. Hence a multistage collimation system has been installed in ord…
Characterization and Tuning of Ultra High Gradient Permanent Magnet Quadrupoles
2009
The application of quadrupole devices with high field gradients and small apertures requires precise control over higher order multipole field components. We present a new scheme for performance control and tuning, which allows the illumination of most of the quadrupole device aperture because of the reduction of higher order field components. Consequently, the size of the aperture can be minimized to match the beam size achieving field gradients of up to $500\text{ }\text{ }\mathrm{T}\text{ }{\mathrm{m}}^{\ensuremath{-}1}$ at good imaging quality. The characterization method based on a Hall probe measurement and a Fourier analysis was confirmed using the high quality electron beam at the M…
Experimental and robust modeling approach for lead(II) uptake by alginate gel beads: influence of the ionic strength and medium composition.
2014
Abstract Systematic kinetic and equilibrium studies on the lead ions removal ability by Ca-alginate gel beads have been performed by varying several internal parameters, namely, number of gel beads, nature and composition of the ionic medium and pH, which allowed us to model a wastewater in order to closely reproduce the composition of a real sample. Moreover, the effects brought about the different ionic species present in the reacting medium have been evaluated. Differential Pulse Anodic Stripping Voltammetry (DP-ASV), has been systematically used to perform kinetic and equilibrium measurements over continuous time in a wide range of concentration. Kinetic and equilibrium data have been q…
Thermal stability of transition alumina nanocrystals with different microstructures
2018
Abstract The preparation of well-crystallized boehmite nanoparticles with different morphologies, encompassing from aciculae or rods of 320, 150 and 70 nm of length to platelets of 50 nm in diameter, allowed a comparative study of their respective thermal evolutions as alumina precursors. Static thermal treatments of boehmite nanocrystals at 600, 1000 and 1200 °C and a dynamic, in situ synchrotron study between 100 and 1000 °C revealed that original boehmite microstructures, i.e. size and shape of the nanoparticles, were kept not only in γ-Al 2 O 3 but also in transitional aluminas up to 1000 °C. Specifically, at that temperature, acicular samples presented θ-Al 2 O 3 structure, while in pl…
Osseotite caricati a due mesi nei settori posteriori del mascellare superiore: controllo a 2 anni di due casi clinici
2003
Aim Acid etched surface implants determine high clinical success rates, but little information is available about early loading in the posterior region of the maxilla, area at risk of failure. The aim of this work is to present two case reports of oral rehabilitation through acid etched surface implants (Osseotite, Implant Innovations - 3i, West Palm Beach, FL) loaded two months after insertion in the posterior maxilla. Materials and methods The success of Osseotite implants was assessed 12 and 24 months after prosthetic loading according to Albrektsson et al. criteria (1986). Results No clinical or radiographic signs of implant failure were observed during the two years follow-up. Conclusi…
Femtosecond up-conversion technique for probing the charge transfer in a P3HT : PCBM blend via photoluminescence quenching
2009
We report on an experimental study of the charge transfer dynamics in a P3HT : PCBM blend by means of a femtosecond fluorescence up-conversion technique. Using two-photon excitation we probe the exciton dynamics in P3HT and a P3HT : PCBM blend with a weight ratio of 1 : 1 at excitation densities of up to 6 × 1018 cm−3. In both samples we find strongly nonexponential decay traces compatible with (i) diffusion-limited exciton–exciton annihilation and (ii) diffusion-limited donor–acceptor charge transfer in the polymer blend. Additionally, our results indicate that in the P3HT : PCBM blend about 50% of the photogenerated excitons undergo a prompt charge transfer process on a time scale of abou…
Calculations of high-power production target and beamdump for the GSI future Super-FRS for a fast extraction scheme at the FAIR Facility
2005
A superconducting fragment separator (Super-FRS) is being designed for the production and separation of radioactive isotopes at the future FAIR (Facility for Antiprotons and Ion Research) facility at Darmstadt. This paper discusses various aspects and requirements for the high-power production target that will be used in the Super-FRS experiments. The production target must survive over an extended period of time as it will be used during the course of many experiments. The specific power deposited by the high intensity beam that will be generated at the future FAIR facility will be high enough to destroy the target in most of the cases as a result of a single shot from the new heavy ion sy…
Electronic properties of Co2MnSi thin films studied by hard x-ray photoelectron spectroscopy
2009
This work reports on the electronic properties of thin films of the Heusler compound Co2MnSi studied by means of hard x-ray photoelectron spectroscopy (HAXPES). The results of photoelectron spectroscopy from multilayered thin films excited by photons of 2?8?keV are presented. The measurements were performed on (substrate/buffer layer/Co2MnSi(z)/capping layer) multilayers with a thickness z ranging from 0 to 50?nm. It is shown that high energy spectroscopy is a valuable tool for non-destructive depth profiling. The experimentally determined values of the inelastic electron mean free path in Co2MnSi increase from about 19.5 to 67?? on increasing the kinetic energy from about 1.9 to 6.8?keV. T…
Combining gestures and vocalizations to imitate sounds
2015
International audience; Communicating about sounds is a difficult task without a technical language, and naïve speakers often rely on different kinds of non-linguistic vocalizations and body gestures (Lemaitre et al. 2014). Previous work has independently studied how effectively people describe sounds with gestures or vocalizations (Caramiaux, 2014, Lemaitre and Rocchesso, 2014). However, speech communication studies suggest a more intimate link between the two processes (Kendon, 2004). Our study thus focused on the combination of manual gestures and non-speech vocalizations in the communication of sounds. We first collected a large database of vocal and gestural imitations of a variety of …