Search results for "Feasibility Studie"
showing 10 items of 252 documents
Laparoscopic Sentinel Lymph Node Detection After Hysteroscopic Injection of Technetium-99 in Patients With Endometrial Cancer
2015
Background and Objectives Endometrial cancer (EC) has an increasing incidence worldwide. Despite the unequivocal prognostic importance of nodal status, systematic lymphadenectomy is associated to elevated morbidity. Sentinel lymph node (SLN) biopsy is designed to avoid extensive nodal dissection and provide crucial oncologic information. The goal of this prospective study was to determine the feasibility, safety, and accuracy of laparoscopic SLN biopsy in EC obtained through hysteroscopic injection of technetium-99 (Tc-99). Methods From January 2008 to December 2012, a total of 42 women with EC were included in the study. We injected 20 mBq of Tc-99 hysteroscopically underneath the tumor mi…
Reply: vascular anatomy of the supraclavicular area revisited
2009
Reply to Letter to Editor
Abdominal Computed Tomography Angiography at 80kV: feasibility study.
2014
preliminary evaluation of different dose reduction algorithms in abdominal Computed Tomography Angiography (CTA) with standard scan protocols at 120kV vs. 80kV.prospective, randomized, crossover study. 60 consecutive patients who underwent CTA of the abdomen (Sensation 64, Siemens; Iomeprol 400 mgl/ml Bracco) for suspected or diagnosed Abdominal Aortic Aneurysm (AAA) were enrolled in the study. A standard 120kV/200mAs scan protocol was acquired in all patients (reference tube current modulated with Automatic Exposure Control). In each patient a second scan with 80kV/300mAs (Group 1; n. 20), 80kV/400mAs (Group 2; n. 20), 80kV/500mAs (Group 3; n. 20) was acquired. We used the same scan/recons…
mHealth for the Monitoring of Brace Compliance and Wellbeing in Adolescents with Idiopathic Scoliosis: Study Protocol for a Feasibility Study
2021
Escoliosis idiopática del adolescente; Aplicación móvil; Eficacia del tratamiento Escoliosi idiopàtica de l'adolescent; Aplicació mòbil; Eficàcia del tractament Adolescent idiopathic scoliosis; Mobile application; Treatment effectiveness Attempts to optimize monitoring of brace adherence prescribed to adolescents with idiopathic scoliosis (IS) have generally relied on sensors. Sensors, however, are intrusive and do not allow the assessment of psychological and physical consequences of brace use that might underlie poor adherence. Mobile applications have emerged as alternatives to monitor brace compliance. However, the feasibility and utility of these app-based systems to assess key psychol…
Dynamic computed tomography: a novel technique to study lung aeration and atelectasis formation during experimental CPR
2002
Objective: To develop an image based technique to study the effect of different ventilatory strategies on lung ventilation and alveolar recruitment during cardiopulmonary resuscitation (CPR). Design: (1) Technical development of the following components: (a) construction of an external chest compression device, which does not interfere with CT imaging, and (b) development of a software tool to detect lung parenchyma automatically and to calculate radiological density parameters. (2) Feasibility studies: three strategies of CPR ventilation were performed and imaged in one animal each (pigs, 25 kg): volume-constant ventilation (VCV), no ventilation, or continuous airway pressure (CPAP). One m…
Potential feasibility of atezolizumab-bevacizumab therapy in patients with hepatocellular carcinoma treated with tyrosine-kinase inhibitors
2022
Background: The combination of atezolizumab-bevacizumab has been proven to be superior to sorafenib for the treatment of unresectable hepatocellular carcinoma not amenable to locoregional treatments, be-coming the standard of care of systemic therapy.Aim: This study aimed at assessing real-world feasibility of atezolizumab-bevacizumab in patients treated with tyrosine-kinase inhibitors.Methods: Among 1447 patients treated with tyrosine-kinase inhibitors from January 2010 to December 2020, we assessed the percentage of those potentially eligible to atezolizumab-bevacizumab (according to IMbrave-150 trial criteria), and the overall survival of eligible and non-eligible patients.Results: 422 (…
Safety and feasibility of atropine added in patients with sub-maximal heart rate during exercise myocardial perfusion SPECT.
2006
Failure to reach 80% of maximal predicted heart rate (HR) during exercise may render a myocardial perfusion single photon emission computed tomography (SPECT) study non-diagnostic for ischemia detection. We sought to investigate the injection of atropine in patients who fail to achieve 80% of age-predicted HR during exercise performed for myocardial perfusion SPECT (MPS), defining its safety and efficacy to raise HR to adequate levels as well as its effect on MPS interpretation.Between January 2002 and December 2004, we studied 3,150 consecutive patients (2,253 men and 897 women, mean age 55 +/- 6 years) who were referred to a single office-based nuclear cardiology laboratory for MPS using …
A novel device for intracolonoscopy cleansing of inadequately prepared colonoscopy patients: a feasibility study.
2019
Abstract Background The importance of high quality preprocedural bowel preparation is widely acknowledged, but suboptimal bowel cleansing still occurs in up to 20 % of all colonoscopy patients. The aim of this study was to evaluate the performance of a novel intraprocedural cleaning device for cleaning poorly prepared colons. Methods This multicenter feasibility study included patients aged 18 – 75 years who were referred for colonoscopy. Intraprocedural cleaning was performed in patients after a limited preprocedural bowel preparation regimen (2 days of dietary restrictions and 2 × 10 mg bisacodyl). The primary outcome was the proportion of adequately prepared patients (Boston Bowel Prepar…
Routine HCV PCR screening of blood donations to identify early HCV infection in blood donors lacking antibodies to HCV
2001
BACKGROUND: Detection of early hepatitis C infection of blood donors is still a major problem for blood transfusion. Common anti-HCV screening assays show differences in sensitivity and specificity. The often mild symptoms of acute hepatitis C also cause difficulties in the identification of early HCV infection. The feasibility and efficacy of routine screening of blood donations for HCV RNA were investigated. STUDY DESIGN AND METHODS: Blood donations (n = 251,737) were screened for HCV RNA over 4 years. RNA extraction, amplification, and detection were done by two commercial HCV PCR kits (HCV Cobas Amplicor and HCV Cobas Amplicor 2.0, Roche Diagnostics). Screening was done by pool testing …
Why do results conflict regarding the prognostic value of the methylation status in colon cancers? The role of the preservation method.
2012
Abstract Background In colorectal carcinoma, extensive gene promoter hypermethylation is called the CpG island methylator phenotype (CIMP). Explaining why studies on CIMP and survival yield conflicting results is essential. Most experiments to measure DNA methylation rely on the sodium bisulfite conversion of unmethylated cytosines into uracils. No study has evaluated the performance of bisulfite conversion and methylation levels from matched cryo-preserved and Formalin-Fixed Paraffin Embedded (FFPE) samples using pyrosequencing. Methods Couples of matched cryo-preserved and FFPE samples from 40 colon adenocarcinomas were analyzed. Rates of bisulfite conversion and levels of methylation of …