Search results for "Feasibility"
showing 10 items of 306 documents
Relocation of Papillary Muscles for Ischemic Mitral Valve Regurgitation
2014
Objective The assessment of the mitral valve apparatus (MVA) and its modifications during ischemic mitral regurgitation (IMR) is better performed by three-dimensional (3D) transesophageal echocardiography (TEE). The aim of our study was to carry out nonrestrictive mitral annuloplasty in addition to relocation of papillary muscles (PPMs) oriented by preoperative real-time 3D TEE through the mitral valve quantification dedicated software. Methods Since January 2008, a total of 70 patients with severe IMR were examined both before and after mitral valve repair. The mean (SD) coaptation depth and the mean (SD) tenting area were 1.4 (0.4) cm and 3.2 (0.5) cm2, respectively. Intraoperative 3D TEE…
Induction of an Anti-Vaccine Response by T Cell Vaccination in Non-human Primates and Humans
1993
Abstract Experimental and spontaneous autoimmune disease in animals can effectively be prevented and treated by application of pathogenic autoreactive T cells in an attenuated form. This approach has become known as T cell vaccination, T cell vaccination exploits specifically the ability of the immune system to regulate its autoreactive T cells by mechanisms of network control. The success of T cell vaccination in a variety of rodent animal models has raised hopes for its use as an effective and specific therapy in human autoimmune disease. The aim of this study was to induce an anti-T cell response by T cell vaccination in humans and primates as a pre-clinical study into the feasibility an…
Small animal tumour imaging with MRI and the ECAT EXACT scanner: application of partial volume correction and comparison with microPET data.
2010
Objective Partial volume effects caused by limited spatial resolution of conventional positron emission tomography (PET) scanners result in an underestimation of the activity concentration in small tumours. The aim of the study was to evaluate the feasibility of small animal tumour imaging with the clinical PET scanner ECAT EXACT after partial volume correction based on MRI calculations. The same tumour model was examined additionally with the small animal PET system, microPET focus 120. Methods Before the ECAT EXACT studies recovery coefficients for different sphere volumes were generated with phantom experiments. For the following in-vivo study DS-sarcoma cells were implanted on both hind…
Controlled Iontophoretic Delivery in Vitro and in Vivo of ARN14140—A Multitarget Compound for Alzheimer’s Disease
2019
ARN14140 is a galantamine-memantine conjugate that acts upon both cholinergic and glutamatergic pathways for better management of Alzheimer's disease. Poor oral bioavailability and pharmacokinetics meant that earlier preclinical in vivo studies employed intracerebroventricular injection to administer ARN14140 directly to the brain. The aim of the present study was to evaluate the feasibility of using constant current transdermal iontophoresis for the noninvasive systemic delivery of ARN14140 and to quantify the amounts present in the blood and the brain. Preliminary experiments in vitro were performed using porcine skin and validated with human skin. Cumulative ARN14140 permeation across th…
A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries.
2016
Abstract Objective The aim of this study was to investigate the 1-year safety and efficacy of a new iliac side-branched device (IBD) for revascularization of the hypogastric arteries. Methods Patients receiving the E-liac (Jotec GmbH, Hechingen, Germany) side-branched device at six German vascular centers either as a stand-alone procedure or in combination with abdominal aortic aneurysm exclusion were included in a prospectively created data bank. Collected data were analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) patency. Results Between January 2012 and January 2015, a total of…
Hybrid Endograft Solution for Complex Iliac Anatomy
2010
The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…
Folfirinox in elderly patients with pancreatic or colorectal cancer-tolerance and efficacy
2016
AIM To study the tolerance and the efficiency of FOLFIRINOX in elderly patients diagnosed with colorectal or pancreatic cancer. METHODS This retrospective study included elderly patients aged over 70 years of age treated at Georges-Francois Leclerc Center by FOLFIRINOX for histological proved colorectal or pancreatic cancer between January 2009 and January 2015. Chemotheapy regimen consisted of oxaliplatin (85 mg/m(2) in over 120 min) followed by leucovorin (400 mg/m(2) in over 120 min), with the addition, after 30 min of irinotecan (180 mg/m(2) in over 90 min) then 5 fluorouracil (5FU) (400 mg/m(2) administred intravenous bolus), followed by 5FU (2400 mg/m2 intraveinous infusion over 46 h)…
Initial experience with a new method of external polyester scaffolding for infrainguinal vein grafts.
2009
Abstract Objectives This study aims to evaluate the feasibility of external polyester scaffolding in infrainguinal bypass grafting when available vein material is suboptimal due to varicosity or dilatation. Primary objectives were short-term primary patency, assisted primary patency and secondary patency. Secondary objectives were to assess the rate of graft stenoses, infections and other adverse effects related to the use of external scaffolding. Materials and methods A total of 50 consecutive patients were included in this prospective, multicentre, feasibility study from six centres. The indication for infrainguinal bypass was critical limb ischaemia (64%), severe claudication (34%) or po…
CT-guided nephrostomy–An expedient tool for complex clinical scenarios
2018
Abstract Introduction & objectives Percutaneous nephrostomy [ 1 ] has emerged as a pivotal approach in the therapeutic management of the obstructed urinary tract. A consecutive incorporation of ultrasonic and radiographic guidance, the approach experienced an almost ubiquitious distribution while most centers currently applying either one or both of these tools jointly. However, success of ultrasound-guidance is limited in obese patients and non-dilated uropathy. In turn, fluoroscopy usually requires an opacification of the urinary collecting system by intravenous or antegrade contrast media injection, which might be harmful for already impaired renal function, raise intrapelvic pressure an…
Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis
2016
International audience; Objective: To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure.Methods: Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intraobserver and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data.Results: Twenty-seven p…