Search results for "Femur"
showing 10 items of 146 documents
Numerical simulations on periprosthetic bone remodeling: a systematic review
2021
Abstract Background and objective The aim of the present study was to review the literature concerning the analysis of periprosthetic bone remodeling through finite element (FE) simulation. Methods A systematic review was conducted on 9 databases, taking into account a ten-year time period (from 2009 until 2020). The inclusion criteria were: articles published in English, publication date after 2009, full text articles, articles containing the keywords both in the abstract and in the title. The articles were classified through the following parameters: dimensionality of the simulation, modelling of the bone-prosthesis interface, output parameters, type of simulated prosthesis, bone remodeli…
2020
Large segmental bone defects occurring after trauma, bone tumors, infections or revision surgeries are a challenge for surgeons. The aim of our study was to develop a new biomaterial utilizing simple and cheap 3D-printing techniques. A porous polylactide (PLA) cylinder was printed and functionalized with stromal-derived factor 1 (SDF-1) or bone morphogenetic protein 7 (BMP-7) immobilized in collagen type I. Biomechanical testing proved biomechanical stability and the scaffolds were implanted into a 6 mm critical size defect in rat femur. Bone growth was observed via x-ray and after 8 weeks, bone regeneration was analyzed with µCT and histological staining methods. Development of non-unions …
Quantitative Anatomical Studies
2015
This special issue of this journal highlights new developments mainly in the field of quantification of the data of anatomical studies. In this special issue, we reviewed and edited seventeen articles from broad ranges of anatomical studies. N. Utkualp and I. Ercan reviewed anthropometric measurement usage in medical sciences from Ancient Egyptian, Greek, and Roman civilizations to those from modern medicine. They also stressed contributions of the well-known scientists to recent diagnostic methods. S. Liao et al. studied the fundamental problem of automatically segmenting teeth in dental mesh models into individual tooth objects and they built a novel dental-targeted harmonic field, which …
Dose Responsive Effects of Subcutaneous Pentosan Polysulfate Injection in Mucopolysaccharidosis Type VI Rats and Comparison to Oral Treatment
2014
Background We previously demonstrated the benefits of daily, oral pentosan polysulfate (PPS) treatment in a rat model of mucopolysaccharidosis (MPS) type VI. Herein we compare these effects to once weekly, subcutaneous (s.c.) injection. The bioavailability of injected PPS is greater than oral, suggesting better delivery to difficult tissues such as bone and cartilage. Injected PPS also effectively treats osteoarthritis in animals, and has shown success in osteoarthritis patients. Methodology/principal findings One-month-old MPS VI rats were given once weekly s.c. injections of PPS (1, 2 and 4 mg/kg, human equivalent dose (HED)), or daily oral PPS (4 mg/kg HED) for 6 months. Serum inflammato…
The Association between Dietary Magnesium Intake and Magnetic Resonance Parameters for Knee Osteoarthritis
2019
The aim of the study was to evaluate the relationship between dietary magnesium (Mg) intake and prevalence of knee osteoarthritis (OA), a topic poorly explored in the literature. Overall, 783 people participating in the Osteoarthritis Initiative (59.8% females
Chondrodysplasia punctata — Rhizomelic form
1976
Pathologic, ultrastructural and radiologic studies are described on 3 infants with the rhizomelic form of chondrodysplasia punctata. Radiologic criteria in the young infant include radiolucent coronal clefts dividing all or most of the thoracic and lumbar vertebral bodies, short humeri with flared metaphyses and punctate calcifications commonly present adjacent to the ossified ischial and pubic bones and less commonly in other locations. In late infancy and childhood the radiologic criteria include demineralization in all bones with slow maturation, flat vertebral bodies, short humeri and femora, metaphyseal flaring, especially in the distal humerus, proximal femur and proximal tibia, immat…
Biomechanical analysis of two types of osseointegrated transfemoral prosthesis
2020
In the last two decades, osseointegrated prostheses have been shown to be a good alternative for lower limb amputees experiencing complications in using a traditional socket-type prosthesis
A case of femoral-facial syndrome in a patient with autism spectrum disorders.
2011
The Femoral hypoplasia - unusual facies syndrome (FHUF) or Femoral - facial syndrome (FFS) was at first described in 1975. Up to now about 60 cases have been reported. According to our knowledge only 4 cases have had congenital central nervous system's malformations, furthermore the main stages of psychomotor development are almost always reported as normal or slightly altered in early childhood. We describe the first case of autism spectrum disorders (ASD) in a patient with FFS, emphasizing that this rare association could be one of many unrecognized underlying features.
Early bone healing around implant surfaces treated with variations in the resorbable blasting media method. A study in rabbits.
2010
Objective: this study aimed to histomorphologically and histomorphometrically evaluate the in vivo response to three variations in the resorbable blasting media (RBM) surface processing in a rabbit femur model. Study Design: screw root form implants with 3.75 mm in diameter by 8 mm in length presenting four surfaces (n=8 each): alumina-blasted/acid-etched (AB/AE), bioresorbable ceramic blasted (TCP), TCP + acid etching, and AB/AE + TCP were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The implants were placed at the distal femur of 8 New Zeland rabbits, remaining for 2 weeks in vivo. After sacrifice, the implants were nondecalcified processed to 30 …
Die Primärstabilität von manuell und roboterassistiert implantierten Hüftendoprothesenstielen: eine biomechanische Untersuchung an Kunstfemora
2004
AIM We investigated the initial stability of cementless stems implanted with robotic milling and conventional manual broaching. METHODS Proximally porous structured stems (G2, ESKA-Implants, Luebeck, Germany) were implanted into synthetic femora. In one group, the femoral cavity was prepared by a CT-based robot (CASPAR, URS-Ortho, Germany) with a high-speed milling head. In the other group, femora were rasped manually with broaches. The broaches had 1 mm proximal press-fit, the robotic cavities 1.5 mm. The implants were exposed to 15 000 loading cycles with 1 000 +/- 500 N. The direction of forces on the implant head were chosen to simulate stair climbing. Internal rotation and translation …