Search results for "Filter"
showing 10 items of 1019 documents
The new nuclide225U
1989
In the bombardment of a 270μg/cm 2 180Hf target with48 Ca projectiles at a primary beam energy of E/A=4.24 MeV/u the new nuclide225U was produced. The experiment was performed at the velocity filter SHIP. 225U was found to decay by α emission with Eα=(7880 ±20) keV (≈90%), (7830±20) keV (≈10%) and has a half-life ofT 1/2=(80 −20 +40 ms).
One-dimensional error-diffusion technique adapted for binarization of rotationally symmetric pupil filters
1995
Abstract Two novel algorithms for the binarization of continuous rotationally symmetric real and positive pupil filters are presented. Both algorithms are based on the one-dimensional error diffusion concept. In our numerical experiment an original gray-tone apodizer is substituted by a set of transparent and opaque concentric annular zones. Depending on the algorithm the resulting binary mask consists of either equal width or equal area zones. The diffractive behavior of binary filters is evaluated. It is shown that the filter with equal width zones gives Fraunhofer diffraction pattern more similar to that of the original gray-tone apodizer than that with equal area zones, assuming in both…
Annular binary filters for controlling the axial behaviour of optical systems
1998
The one-dimensional (1D) version of the iterative Fourier transform algorithm (IFTA) and a modified error diffusion algorithm are proposed for binarizing rotationally symmetric pupil filters designed to shape the axial impulse response of optical system. The resulting binary masks consist of a set of transparent and opaque annular zones of equal area or equal width. A numerical experiment in which we examine the performance of the binarization methods is carried out. In this experiment the resemblance between the axial diffractive behaviour of the binary version of an axially superresolving pupil filter, and that of the original continuous-tone filter is evaluated. It is shown that the perf…
All-fiber incoherent frequency-to-time mapping method for microwave signal generation with baseband transmission and multicasting support
2008
We present a proof-of-principle experiment for achieving simultaneous distribution of baseband radio-frequency data and up-conversion with broadcasting support over a passive optical network. The technique is based on an incoherent frequency-to-time mapping method for pulse shaping. Specifically, we synthesize the spectral density function of sliced ASE noise from an EDFA with a periodic Mach-Zehnder fiber interferometer optical filter. By using external intensity modulation combined with propagation in an optical fiber, after photodetection, the resultant averaged temporal pulse profile resembles the shape of the incoherent source. The photodetected signal contains both the baseband data a…
Incoherent photonic techniques for RF-AWG
2010
The capabilities for RF-AWG in terms of waveform fidelity for three different incoherent photonic methods are revised and discussed: incoherent frequency-to-time mapping, incoherent MWP filtering with N discrete taps, and multi-wavelength pulse compression.
Radiating and nonradiating behavior of hyperbolic-secant, raised-cosine, and Gaussian input light pulses in dispersion-managed fiber systems.
2005
We address the problem of optical light pulses, called dressed pulses, which do not match the stationary pulse profile of a dispersion-managed (DM) fiber system and we theoretically analyze the associated radiation. Comparing hyperbolic-secant, raised-cosine, and Gaussian pulse envelopes, we show that the general radiation figure is highly sensitive to the input pulse profile. As common general features for these pulse profiles, we find a rich variety of dynamical states that includes weak-, moderate-, and strong-radiation states, depending on the map strength of the DM fiber system. We demonstrate the existence of two intervals of map strengths where the emitted radiation is of considerabl…
1 Tb/s·km WDM transmission over multimode fibre link
2008
We demonstrate 1 Tb/smiddotkm WDM error-free transmission (highest reported value to our knowledge) over a MMF link by a combination of low-linewidth lasers and central launch.
Photonic microwave tunable single-bandpass filter based on a Mach-Zehnder interferometer
2006
The authors present the theoretical analysis and experimental demonstration of a novel single-bandpass tunable microwave filter. The filter is based on a broadband optical source and a fiber Mach-Zehnder interferometer and shows a high Q factor over a tuning range of 5-17 GHz. A generalized analysis considering that the optical signal propagates along optical delay lines with a dispersion slope different from zero is presented.
Fractional Tajimi–Kanai model for simulating earthquake ground motion
2014
The ground acceleration is usually modeled as a filtered Gaussian process. The most common model is a Tajimi–Kanai (TK) filter that is a viscoelastic Kelvin–Voigt unit (a spring in parallel with a dashpot) carrying a mass excited by a white noise (acceleration at the bedrock). Based upon the observation that every real material exhibits a power law trend in the creep test, in this paper it is proposed the substitution of the purely viscous element in the Kelvin Voigt element with the so called springpot that is an element having an intermediate behavior between purely elastic (spring) and purely viscous (dashpot) behavior ruled by fractional operator. With this choice two main goals are rea…
An angular-selective electron source for the KATRIN experiment
2014
The KATRIN experiment is going to search for the average mass of the electron antineutrino with a sensitivity of 0.2 eV/c2. It uses a retardation spectrometer of MAC-E filter type to accurately measure the shape of the electron spectrum at the endpoint of tritium beta decay. In order to achieve the planned sensitivity the transmission properties of the spectrometer have to be understood with high precision for all initial conditions. For this purpose an electron source has been developed that emits single electrons at adjustable total energy and adjustable emission angle. The emission is pointlike and can be moved across the full flux tube that is imaged onto the detector. Here, we demonstr…