Search results for "Fixation"

showing 10 items of 482 documents

Current Clinical Application of Microperimetry: A Review.

2018

Microperimetry (MP) is a technology that allows the study of retinal sensitivity at different foveal and parafoveal areas as well as eye fixation. It is a technique of functional evaluation, providing a direct correlation between anatomical and functional outcomes. There are a great variety of studies which evaluate the repeatability or reliability of measurements obtained with this technology and also describe and explore different clinical applications. MP has been shown to be useful in the characterization of sensory and motor conditions, such as amblyopia or nystagmus. Concerning ocular pathology, several studies have confirmed the usefulness of MP for evaluating and analyzing different…

medicine.medical_specialtygenetic structuresOcular PathologyGlaucomaNystagmusFixation OcularAmblyopiaMicroperimetryOcular Motility Disorders03 medical and health scienceschemistry.chemical_compoundNystagmus0302 clinical medicineOcular Motility DisordersRetinal DiseasesFovealOphthalmologymedicineHumansRetinal sensitivityVisual rehabilitationÓpticabusiness.industryReproducibility of ResultsRetinalGeneral MedicineMacular degenerationmedicine.diseaseeye diseasesOphthalmologychemistryEye fixation030221 ophthalmology & optometryVisual Field Testsmedicine.symptomVisual FieldsbusinessMicroperimetry030217 neurology & neurosurgerySeminars in ophthalmology
researchProduct

Optic neuropathy caused by type A botulinic toxin

2014

Purpose To report the development of an optical neuropathy after injection of type A botulinic toxin in a subject with blepharospasm. Methods Optical neuropathy was evaluated through a complete ophthalmologic examination consisting of bio-microscopy, tonometry and study of visual sharpness, colour test, visual field, OCT, fluorangiography and determination of VEPs. Results Intravenous therapy was begun with Metilprednisolone (20 mg/Kg/day) and Vitamin B6 associated with oral Citicoline, and there was a clear improvement down to normalization of the symptoms. After 6 months the Humphrey computerized visual field with central 30-2 program threshold test emphasised in ODx an upper half-field a…

medicine.medical_specialtygenetic structuresmedicine.diagnostic_testbusiness.industryThreshold testSettore MED/30 - Malattie Apparato VisivoBlepharospasmGeneral MedicineBlepharospasm Type A botulinic toxin Optic neuropathymedicine.diseaseeye diseasesSurgeryVisual fieldOptic neuropathyMajor duodenal papillaPerimeterOphthalmologyOptical coherence tomographyOphthalmologyFixation (visual)medicineType A botulinic toxinsense organsmedicine.symptombusiness
researchProduct

New Forceps and Spatula for Easy Retropupillary Implantation of Iris Claw Lenses in Aphakia: Experience in 4 Years of Use

2008

PURPOSE. Retropupillary implantation of an iris claw lens offers a rapid and atraumatic approach for rehabilitation of aphakic eyes. The difficulty in the implantation process arises because of the possibility of losing the intraocular lens (IOL) into the vitreous cavity and the need to change the hand holding the forceps during the enclavation. M ETHODS. The new forceps design radically changes the method of grasping an IOL. It contains an extendable supporting plate with a hook-like end. The instrument achieves a horizontal three-point fixation at the edge of the implant in the 6 and 12 o’clock position in order to prevent slippage into the vitreous cavity during the inclination. The supp…

medicine.medical_specialtygenetic structuresmedicine.medical_treatmentForcepsIrisIntraocular lensAphakia PostcataractAphakiaVitreous cavitylaw.inventionFixation (surgical)Lens Implantation IntraocularlawOphthalmologymedicineHumansIris clawLenses IntraocularPhacoemulsificationbusiness.industryEquipment DesignGeneral Medicinemedicine.diseaseCentrationeye diseasesSurgeryLens (optics)Ophthalmologysense organsbusinessEuropean Journal of Ophthalmology
researchProduct

Long-term clinical and radiological outcomes following anterior cervical discectomy and fusion by zero-profile anchored cage

2018

Objectives: The purpose of this study was to extend the results of our previous study providing a minimum of 4-year follow-up results of a prospective study following implantation of a cervical cage with an integrated fixation system. Summary of Background Data: The use of cervical intersomatic cages with an integrated fixation system for anterior cervical discectomy and fusion (ACDF) has increased rapidly in this last decade. In addition to immediate stabilization, these implants allow avoidance of anterior plating and iliac crest bone-grafting. Methods: Patients were studied prospectively, and data were collected and analyzed. Intersomatic cages with an integrated fixation system were use…

medicine.medical_specialtylcsh:Diseases of the musculoskeletal systemVisual analogue scaleAnterior cervical discectomy and fusionIliac crest03 medical and health sciencesFixation (surgical)0302 clinical medicinemedicineProspective cohort studycervical disc herniation030222 orthopedicsCobb anglebusiness.industryAnterior cervical discectomy fusionSurgerymedicine.anatomical_structurecervical spondylosis functional scoresOrthopedic surgeryOriginal ArticleSurgeryNeurology (clinical)Implantlcsh:RC925-935business030217 neurology & neurosurgeryJournal of Craniovertebral Junction and Spine
researchProduct

Diagnostische Möglichkeiten und Behandlungsstrategien für die Fraktur der Eminentia intercondylica im Wachstumsalter

1995

Between 1970 and 1993 29 fractures of the intercondylar eminence were seen in children with almost the same number of cases showing no or minor displacement as those requiring open reduction for major dislocation. Combined knee injury must be suspected the higher the patient's age and the more pronounced the displacement of the fragment. Magnetic resonance imaging (MRI) has gained diagnostic predominance. Arthroscopy remains important for surgical management, especially of associated meniscus and cartilage damage. Early puncture of hemarthrosis is essential. Closed management is the therapy for nondisplaced fragments or those with bone contact or only tuberculum fractures--while displaced f…

medicine.medical_specialtymedicine.diagnostic_testSports medicinebusiness.industryRadiographyArthroscopyMagnetic resonance imagingHemarthrosismedicine.diseaseSurgerySalter–Harris fractureFracture fixationOrthopedic surgeryMedicineSurgerybusinessUnfallchirurgie
researchProduct

Leg extension power deficit and mobility limitation in women recovering from hip fracture.

2008

OBJECTIVE: After hip fracture, muscle strength and power remain persistently poor, especially in the fractured leg. This study explores whether asymmetrical leg extension power (LEP) deficit affects mobility in women after proximal femoral fracture (PFF). DESIGN: In this observational study, LEP of both legs, 10- and 50-foot walking speed, and stair-climbing speed were measured in 43 women, aged 73-96, at 1 and 13 wks after surgical repair of PFF. Asymmetrical LEP deficit was calculated as (fractured/(sum both legs)) x 100%. RESULTS: Between weeks 1 and 13 after PFF surgery, LEP increased in the fractured and nonfractured legs by 100% and 30%, respectively. Asymmetrical deficit was reduced …

medicine.medical_specialtymedicine.medical_treatmentArthroplasty Replacement HipPhysical Therapy Sports Therapy and RehabilitationWalkingmedicine.disease_causeWeight-bearingWeight-BearingFracture Fixation InternalPhysical medicine and rehabilitationFracture fixationmedicineHumansMuscle StrengthMobility LimitationAgedAged 80 and overHip fractureRehabilitationbusiness.industryHip FracturesRehabilitationFemoral fractureRecovery of Functionmedicine.diseaseArthroplastyPreferred walking speedMobility LimitationLower ExtremityPhysical therapyExercise TestFemalebusinesshuman activitiesAmerican journal of physical medicine and rehabilitation / Association of Academic Physiatrists
researchProduct

Fixation free inguinal hernia repair with the 3D dynamic responsive prosthesis ProFlor: Features, procedural steps and long-term results

2019

Abstract Background Static and fixated meshes to repair mobile structures like the groin may seem a procedural incongruence. Inguinal hernia is described as a degenerative disease. Therefore, the objective of disease treatment should be the regeneration of wasted tissue. The fibrotic scar plate, a typical biologic response of conventional static meshes, does not represent tissue regeneration but rather a foreign body reaction. These contrasting aspects seem to be related to high complication rates of inguinal herniorrhaphy. Recent studies concerning the pathophysiology of the groin have led to the development of new concepts for repairing inguinal protrusions. A proprietary designed 3D dyna…

medicine.medical_specialtymedicine.medical_treatmentBiologic responseProsthesis03 medical and health sciences0302 clinical medicineDegenerative diseasemedicineTissue scaffoldsFixation (histology)Groinbusiness.industryDynamic responsive prosthesiInguinal herniaChronic painmedicine.diseaseSurgeryInguinal herniaSettore MED/18 - Chirurgia Generalemedicine.anatomical_structure030220 oncology & carcinogenesisTissue regeneration030211 gastroenterology & hepatologySurgeryImplantForeign bodybusiness
researchProduct

Circumferential graft for elbow instability

2019

For those patients with instability of the medial and lateral sided of the elbow, there is a place for a circumferential graft. This has the main advantage of simplifying the bone tunnel creation and graft fixation, compared to having both medial- and lateral-sided reconstructions.

medicine.medical_specialtysurgical procedures operativemedicine.anatomical_structurebusiness.industryElbowMedicineBone tunnelGraft fixationbusinessInstabilitySurgerycircumferential graft elbow instability
researchProduct

Cement augmentation for trochanteric fracture in elderly: A systematic review()

2021

Abstract Background Cement augmentation of internal fixation of hip fracture has reported to improve fracture stability in osteoporotic hip fractures, reducing the risk of cut-out of the sliding screw through the femoral head. The purpose of present study was to perform a systematic literature review on the effects of augmentation technique in patients with osteoporotic hip fractures. Material and methods A comprehensive literature search was systematically performed to evaluate all papers published in English language included in the literature between January 2010 and July 2020, according to the PRISMA 2009 guidelines. In vivo and in vitro studies, case reports, review articles, cadaveric…

medicine.medical_treatmentOsteoporosisDentistryScrew mobilizationCement augmentation03 medical and health sciencesFemoral head0302 clinical medicinemedicineInternal fixationOrthopedics and Sports Medicine030212 general & internal medicineCut-out risk030222 orthopedicsHip fractureFemur fractureFemur fracturebusiness.industrymedicine.diseasemedicine.anatomical_structureSystematic reviewEditorialHarris Hip ScoreOsteoporosisbusinessCadaveric spasm
researchProduct

Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

2007

Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs.Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0…

medicine.medical_treatmentTorsion MechanicalOsteotomyProsthesis DesignFracture Fixation InternalCadaverFracture fixationBone plateMaterials TestingmedicineCadaverInternal fixationHumansOrthopedics and Sports MedicineOrthodonticsUniversal testing machineOsteosynthesisbusiness.industryAnatomyRadiographySurgeryImplantStress MechanicalbusinessRadius FracturesBone PlatesThe Journal of hand surgery
researchProduct