Search results for "Flow Rate"

showing 10 items of 166 documents

Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review

2016

Liquid chromatography with single columns often does not succeed in the analysis of complex samples, in terms of resolution and analysis time. A relatively simple solution to enhance chromatographic resolution is the modulation of the stationary phase through the serial coupling of columns. This can be implemented with any type of column using compatible elution conditions and conventional instruments. This review describes the key features of column coupling and published procedures, where two or more columns were coupled in series to solve separation problems. In all reports, the authors could not resolve their samples with single columns, whereas significant enhancement in chromatographi…

Chromatography010405 organic chemistryChemistryElution010401 analytical chemistryKey features01 natural sciencesBiochemistryMass spectrometricDead volume0104 chemical sciencesAnalytical ChemistryVolumetric flow rateTwo-dimensional chromatographyStationary phaseEnvironmental ChemistryChromatography columnSpectroscopyAnalytica Chimica Acta
researchProduct

Channel flow at an immobilised liquid|liquid interface

2000

A novel rectangular channel flow electrochemical cell for the study of liquid | liquid interfaces is presented. The organic phase is immobilised by the use of a gelling agent, while the aqueous phase flows past the interface. This creates an asymmetric setup that allows us to establish diagnostic criteria to determine, for example, the direction of the ion transfer. The effects of varying flow rate and sweep rate have been considered both theoretically and experimentally. By comparison with two-dimensional simulations, it is demonstrated that a simple one-dimensional theory can be used to describe the cyclic voltammetry response of the channel flow cell.

ChromatographyAqueous solutionChemistryGeneral Chemical EngineeringAqueous two-phase systemMechanicsAnalytical ChemistryOpen-channel flowElectrochemical cellVolumetric flow ratePhysics::Fluid DynamicsPhase (matter)ElectrochemistryITIESCyclic voltammetryJournal of Electroanalytical Chemistry
researchProduct

Abatement of Acid Orange 7 in macro and micro reactors. Effect of the electrocatalytic route

2014

Abstract The electrochemical treatment of aqueous solutions contaminated by Acid Orange 7 (AO7) was widely studied with the main objective to evaluate as the electrocatalytic route affects the performances of the degradation process in macro and microfluidic cells. Direct anodic oxidation (EO), electro-Fenton (EF), electro-generation of active chlorine (IOAC) and coupled processes were investigated in macro and microfluidic reactors in order to select more effective conditions for the treatment of such compound. The effect of numerous operative parameters (such as nature of the electrode materials, coupling of processes, flow rate, current density and inter-electrode distance) on the perfor…

ChromatographyAqueous solutionSupporting electrolyteChemistryProcess Chemistry and TechnologyElectrocatalysiElectrochemistryElectrocatalystCatalysisCatalysisVolumetric flow rateChemical engineeringMass transferActive chlorineAcid Orange 7Electro-FentonMicroreactorMicro reactorBDDGeneral Environmental Science
researchProduct

Isovaleraldehyde degradation using UV photocatalytic and dielectric barrier discharge reactors, and their combinations

2015

International audience; The abatement of isovaleraldehyde present in air was carried out in UV photocatalytic and dielectric barrier discharge reactors (and their combinations) for concentrations up to 150 mg C m−3 and air flow rates ranging from 4 to 10 m3 h−1. A kinetic study was performed following a Langmuir–Hinshelwood model. Photocatalytic treatment of an isovaleraldehyde and isovaleric acid mixture showed a clear inhibition of isovaleric acid abatement in presence of isovaleraldehyde. Dielectric barrier discharge treatment of isovaleraldehyde showed an increase of removal efficiency with applied voltage and a decrease with air flow rate and inlet concentration. Moreover, introduction…

ChromatographyChemistryGeneral Chemical EngineeringInorganic chemistryDielectric barrier discharge treatmentGeneral Physics and AstronomyGeneral ChemistryDielectric barrier dischargeQuímicaUV photocatalytic reactor6. Clean waterIsovaleraldehydeCatalysischemistry.chemical_compoundCombined treatment[CHIM.GENI]Chemical Sciences/Chemical engineeringCoupled systemAir flow ratePhotocatalysisDegradation (geology)Hybrid reactorHybrid reactorEnginyeria ambientalVOC removal
researchProduct

A theoretical plate model accounting for slow kinetics in chromatographic elution.

2011

The chromatographic elution has been studied from different perspectives. However, in spite of the simplicity and evident deficiencies of the plate model proposed by Martin and Synge, it has served as a basis for the characterization of columns up-to-date. This approach envisions the chromatographic column as an arbitrary number of theoretical plates, each of them consisting of identical repeating portions of mobile phase and stationary phase. Solutes partition between both phases, reaching the equilibrium. Mobile phase transference between the theoretical plates is assumed to be infinitesimally stepwise (or continuous), giving rise to the mixing of the solutions in adjacent plates. This yi…

ChromatographyComputer simulationElutionChemistryOrganic ChemistryKineticsGeneral MedicineModels TheoreticalKinetic energyBiochemistryAnalytical ChemistryVolumetric flow rateSolutionsKineticsPharmaceutical PreparationsMass transferPartition (number theory)Theoretical plateChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

CO2 conversion in a photocatalytic continuous membrane reactor

2016

The reduction of CO2 with water by using photocatalysts is one of the most promising new methods for achieving CO2 conversion to valuable hydrocarbons such as methanol (MeOH). In this work, prepared TiO2-Nafion (TM)-based membranes were used in a photocatalytic membrane reactor, operated in continuous mode, for converting CO2 to methanol. By using the membrane with the best TiO2 distribution, a MeOH flow rate/TiO2 weight of 45 mu mol (g(catalyst) h)(-1) was measured when operating at 2 bar of feed pressure. This value is higher than those reported in most of the literature data to date. Moreover, methanol production is considered as a relevant advance over the existing literature results wh…

ChromatographyMembrane reactorChemistryGeneral Chemical EngineeringCO2 photocatalytic conversionmembrane reactor02 engineering and technologyGeneral ChemistryContinuous mode010402 general chemistry021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesVolumetric flow ratechemistry.chemical_compoundMembraneChemical engineeringPhotocatalysisPhotocatalytic CO2 conversion membrane reactor TiO2Settore CHIM/07 - Fondamenti Chimici Delle TecnologieMethanol0210 nano-technologyFeed pressureBar (unit)RSC Advances
researchProduct

Interpretive optimisation of organic solvent content and flow-rate in the separation of β-blockers with a Chromolith RP-18e column

2009

The chromatographic performance of a Chromolith RP-18e column was comprehensively examined for a group of basic drugs (beta-blockers), eluted with isocratic ACN-water mixtures at increasing flow-rate up to 6 mL/min. As the flow-rate increases at fixed mobile phase composition, peak distribution (selectivity) is maintained, but the relative peak widths increase. This reduces the resolution below satisfactory values for closely eluting compounds. With the monolithic column, flow-rate becomes thus an important factor to be optimised, in addition to the mobile phase composition. Since, theoretically, retention factors (k) are independent of the flow-rate, the classical quadratic model relating …

ChromatographyMonolithic HPLC columnResolution (mass spectrometry)ChemistryElutionAdrenergic beta-AntagonistsAnalytical chemistryFiltration and SeparationReversed-phase chromatographyHigh-performance liquid chromatographyAnalytical ChemistryVolumetric flow rateSolventModels ChemicalSolventsOrganic ChemicalsSelectivityChromatography High Pressure LiquidJournal of Separation Science
researchProduct

Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins

2007

In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Bo…

ChromatographyMonolithic HPLC columnSilicon dioxideElutionOrganic ChemistryAnalytical chemistryProteinsReproducibility of ResultsGeneral MedicineReversed-phase chromatographySilicon DioxideBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryVolumetric flow ratechemistry.chemical_compoundchemistryPhase (matter)PeptidesMesoporous materialPorosityChromatography LiquidJournal of Chromatography A
researchProduct

Description of the Retention and Peak Profile for Chromolith Columns in Isocratic and Gradient Elution Using Mobile Phase Composition and Flow Rate a…

2014

The effect of the modifier concentration and flow rate on the chromatographic performance of a second generation Chromolith® RP-18e column, under isocratic and gradient elution with acetonitrile-water mixtures, was examined using four sulphonamides as probe compounds. The acetonitrile concentration was varied between 5 and 55% (v/v), and the flow rate between 0.1 and 5.0 mL/min, keeping the other factors constant. The changes in both retention and peak profile were modelled, and used to build simple plots, where the logarithm of the retention factor was represented against the modifier concentration (in gradient elution, against the initial modifier concentration), and the half-widths or wi…

Chromatographyflow programmingChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyisocratic elutionFirst generationVolumetric flow ratelcsh:Chemistrymodellingchemistry.chemical_compoundreversed-phase liquid chromatographygradient elutionlcsh:QD1-999ChromolithPhase compositionInteraction kineticsGradient elutionAcetonitrileRetention timeChromatography
researchProduct

Solid-liquid mass transfer coefficients in gas-solid-liquid agitated vessels

1998

The research on mass transfer coefficients in solid-liquid agitated systems has received substantial attention in the past, due both to the interest in fundamental aspects of mass transfer between particles and turbulent fluids and to the importance of practical applications. In contrast, little information is available on solid-liquid mass transfer when a third gaseous phase is also dispersed into the system, in spite of the importance of the applications of gas-solid-liquid agitated systems. In this work a suitable dissolution technique was used to measure the solid-liquid mass transfer coefficient in gas-solid-liquid vessels stirred by either radial or axial impellers. The mechanical pow…

Condensed Matter::Soft Condensed MatterPhysics::Fluid DynamicsMass transfer coefficientWork (thermodynamics)TurbulenceChemistryGeneral Chemical EngineeringPhase (matter)Mass transferThermodynamicsDissipationDissolutionVolumetric flow rate
researchProduct