Search results for "Flow injection analysis"
showing 3 items of 73 documents
Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals
2007
Abstract A review is presented on the state of the art of the chemiluminescence analysis of pharmaceuticals by the two most relevant automated controlled-flow methodologies—flow-injection analysis (FIA) and sequential-injection analysis (SIA). The current chemiluminometric applications of FIA and SIA in pharmaceutical analysis are discussed with special emphasis on the analytical figures of merit and sample matrix characteristics. The review involving 211 references and covering papers published between 2001 and 2006 is divided into several sections according to the fundamental types of chemiluminescence systems employed.
LC of high to moderately polar basic drugs in urine with water and detergent, and direct injection
2016
Background: Micellar LC was first proposed as a ‘green’ mode using mobile phases of water and surfactant. However, in most procedures a small amount of organic solvent is required to decrease the retention to convenient values. Results & methodology: Mixed micellar mobile phases prepared with both cationic (sodium dodecyl sulphate) and nonionic surfactant (Brij-35) modulate the retention of high to moderately polar basic drugs to practical times, eliminating the need of organic solvent. While the mobile phase is continuously recycled through the system, the stationary phase performance is maintained after repetitive injection of the samples. Discussion & conclusion: Through an exte…
Towards minimization of chlorinated solvents consume in Fourier transform infrared spectroscopy determination of Propamocarb in pesticide formulation…
2008
Abstract A method has been developed for Fourier transform infrared (FTIR) spectroscopy determination of Propamocarb in emulsifiable pesticide concentrate formulations. Five microliter sample was directly injected without any pretreatment in a CHCl 3 stream at 2 mL min −1 into a closed system and the FTIR spectra of sample and standard solutions were obtained using a nominal resolution of 4 cm −1 from 4000 to 900 cm −1 spectral region and accumulating 2 scans per spectrum. Propamocarb determination was based on the measurement of flow injection analysis (FIA) recording height established from FTIR peak area measurements from 1713 to 1703 cm −1 corrected using a baseline defined at 2000 cm −…