Search results for "Flow"
showing 10 items of 5185 documents
Human cerebral microcirculation and oxygen saturation during propofol-induced reduction of bispectral index †
2011
† This study investigates the effects of propofol-induced changes in bispectral index (BIS) on cerebral microcirculation and oxygenation during craniotomies. † In 2 mm cerebral depth, an increase in propofol dosage resulted in increased oxygen saturation (srvO2 )w ithout reduction of capillary venous blood flow (rvCBF). † Difference in oxygen content (avDO2) and approximated cerebralmetabolicrateofoxygen (aCMRO2) decreased with an increase in propofol dosage in 2 mm cerebral depth. † Alterations in BIS showed no effect on rvCBF, srvO2 ,a nd haemoglobin amount (rvHb) or on avDO2 or aCMRO2 in 8 mm cerebral depth. † These findings suggest that the CBF/CMRO2 ratio is altered by propofol in a re…
Flow cytometric analysis of glyoxalase-1 expression in human leukocytes.
2011
Altered glyoxalase-1 (GLO-1) activity and expression is associated with the development of late diabetic complications, malignancy and oxidative stress- and aging-related diseases. In the present study, we developed a flow cytometry method for GLO-1 detection in human leukocytes isolated from peripheral blood samples to investigate GLO-1 expression in leukocyte subsets from type 1 and 2 diabetes mellitus patients (n = 11) and healthy subjects (n = 8). The flow cytometry analysis of GLO-1 in leukocytes showed that expression index of GLO-1-positive cells was slightly increased in mononuclear leukocytes from diabetic patients. This result correlated with the increase in GLO-1 activity in the …
Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods
2015
Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To fur…
Pentoxifylline Inhibits Vγ9/Vδ2 T Lymphocyte Activation of Patients with Active Behçet's Disease in Vitro
2007
The aim of this study is to evaluate the in vitro effect of pentoxifylline (PTX) on T Vgamma9/Vdelta2 lymphocyte function in Behçets disease (BD). We investigated the effect of PTX on Vgamma9/Vdelta2 T cell expansion and expression of TNFRII receptor and perforin content before and after PTX addition by means of FACS analysis lymphocyte cultures from patients with active and inactive BD and healthy subjects. The addition of PTX at a concentration of 1 mg/ml determined a significant inhibition of cell expansion, a down regulation of TNF receptor expression and inhibited the PMA-induced degranulation of perforin. Taken together these data indicate that PTX is capable of interfering with Vgamm…
Transitional hemodynamics in infants of diabetic mothers by targeted neonatal echocardiography, electrocardiography and peripheral flow study
2017
Objective: Metabolic alterations of intrauterine environment in diabetes mellitus (DM) lead to fetal cardiac dysfunctions that can persist after birth. The aim of the study was to assess the cardiovascular adaptation in infants born to diabetic mothers (IDM) with different degrees of glycometabolic control, in relation to revised guidelines for diagnosis of DM and quality improvements in neonatal care. Materials and methods: An observational case-control study was conducted on IDM with gestational, type 1 and type 2âDM. Relevant maternal and neonatal anamnestic, clinical and laboratory data were analyzed. Electrocardiographic and echocardiographic analyses, including structural and systo-…
Transcranial Doppler ultrasound study of the effects of nitrous oxide on cerebral autoregulation during neurosurgical anesthesia: a randomized contro…
2003
Object. Nitrous oxide has an adverse effect on cerebrovascular hemodynamics. Increased intracranial pressure, cerebral blood flow (CBF), cerebral metabolic rate of O2 (CMRO2), and reduced autoregulation indices have been reported, but their magnitudes are still being debated. This study was designed to evaluate the effect of N2O on CBF and autoregulatory indexes during N2O—sevoflurane anesthesia in a prospective randomized controlled series of patients. Methods. Two groups of 20 patients were studied on the basis of the use of N2O in the anesthetic gas mixture. The transient hyperemic response test, which relies on transcranial Doppler ultrasound techniques, was used to assess cerebral hemo…
Color-coded duplex ultrasonography of the origin of the vertebral artery: normal values of flow velocities.
2000
The introduction of color-coded duplex ultrasonography has improved the ease of performing ultrasound investigations of the vertebral arteries. So far, normal values of flow velocities have been reported only for the intertransverse region of the vertebral artery (V2 segments). Atherosclerotic disease at the origin of the vertebral arteries (V0 segment) is frequent and is one of the risk factors for vertebrobasilar ischemic disease. Normal values of flow velocities of the vertebral artery origin are needed to assess pathologic findings, such as vertebral artery origin stenosis or dissection. The aim of this study was to describe the normal flow velocities of vertebral artery origin (V0 segm…
Evaluation of regional haemodynamics and alterations of vascular wall of the lower limbs in hypertensive subjects
1995
This study was designed to analyse the relationship between arterial hypertension and changes in arterial blood flow and vascular wall damage of the lower limbs in hypertensive patients with various degrees of hypertension. Six hundred and fifty-four hypertensive patients (421 males and 233 females) aged 35 to 70 years and 88 healthy subjects (63 males and 25 females) aged 39 to 60 years were studied. Strain-gauge plethysmography of the lower limbs was used to calculate arterial calf blood flow (RF), arterial calf blood flow after post-ischaemic hyperaemia (PF), basal and minimal vascular resistances (BVR and MVR), time to reach peak flow (tPF), time until 50% reduction of peak flow (tT1/2)…
Brain activity during intra- and cross-modal priming: new empirical data and review of the literature
2003
A positron emission tomography (PET) study was conducted to investigate the neurofunctional correlate of auditory within-modality and auditory-to-visual cross-modality stem completion priming. Compared to the auditory-to-auditory priming condition, cross-modality priming was associated with a significantly larger regional cerebral blood flow (rCBF) decrease at the boundary between left inferior temporal and fusiform gyri, brain regions previously associated with modality independent lexical retrieval and reading. Instead, within-modality auditory priming was associated with a bilateral pattern of prefrontal rCBF increase. This was likely the expression of more efficient access to output lex…
The quantitative humoral immune response to the hepatitis C virus is correlated with disease activity and response to interferon-alpha.
1996
Virus-host interactions may have pathogenetic significance in chronic hepatitis. Thus the humoral immune response was evaluated during the clinical course of HCV-infected patients.Eighteen selected chronic HCV patients received three doses of 3 or 6 MU interferon-alpha 2a weekly for 6 to 12 months and were followed up for 6 to 60 months. Anti-HCV antibody levels were serially measured either in end-point diluted sera with the Matrix-Assay or with quantitative anti-HC34-IgG and -IgM ELISA. Circulating immune complexes were assessed by flow cytometry and the results were correlated with histology, quantitative HCV-RNA levels and genotypes.Nine complete responders (CR; genotypes 1a n = 4; 1b n…