Search results for "Flow"
showing 10 items of 5185 documents
HLA-B27-derived peptides as autoantigens for T lymphocytes in ankylosing spondylitis
1997
Objective.To study whether peptides derived from the HLA-B27 molecule sequence can stimulate peripheral blood T lymphocytes (PBL) from patients with HLA-B27-associated spondylarthropathies. Methods.PBL from 55 HLA-B27+ patients with ankylosing spondylitis (AS), 28 HLA-B27+ patients with other spondylarthropathies, 7 rheumatoid arthritis patients, and 30 HLA-B27+ and 22 HLA-B27- healthy controls were tested in lymphocyte proliferation assays with 4 synthetic peptides derived from the HLA-B*2705 molecule. Results. A 13-mer peptide (B27PA) induced significant proliferative responses in 17 of the 55 AS patients (stimulation index [SI] 2.5–17.5), as well as in 3 of the HLA-B27+ healthy controls …
Regression of structural vascular changes in hypertensives after captopril treatment.
1992
In order to investigate whether hypertension-related structural vascular changes may be influenced by antihypertensive treatment, 10 patients were studied suffering from essential arterial hypertension, five males and five females, aged between 34 and 61 years (mean age: 46.9 +/- 8.13 years). All patients received a placebo for 1 week and then captopril, 75 mg b.i.d. for 3 months. After placebo and captopril treatments, the following parameters were evaluated: SBP, DBP, mean blood pressure (MBP), by the formula 1/3 (SBP + 2 x DBP) and basal and minimal vascular resistances, respectively obtained by the ratios MBP/rest flow and MBP/peak flow. Blood flows have been obtained by strain gauge pl…
Blood flow velocity waveforms of the fetal middle cerebral artery in a normal population: reference values from 18 weeks to 42 weeks of gestation
2002
The aim of this prospective cross-sectional study was to establish new Doppler reference curves for peak blood flow velocities (Vmax, Vmean, Vmin) and impedance indices (PI, RI) of the middle cerebral artery at 18-42 weeks of gestation by an automatic wave form analysis integrated into the ultrasound device. In 962 low-risk pregnancies, blood flow velocities were derived from the middle cerebral artery with pulsed color Doppler ultrasonography. Reference curves were constructed for the individual parameters based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square principle for maximum blood flow velocities, as well as on a pol…
Nitric oxide production and endothelium-dependent vasorelaxation ameliorated by N1-methylnicotinamide in human blood vessels.
2012
N 1 -methylnicotinamide (MNA + ) has until recently been thought to be a biologically inactive product of nicotinamide metabolism in the pyridine nucleotides pathway. However, the latest observations imply that MNA + may exert antithrombotic and anti-inflammatory effects through direct action on the endothelium. We examined both in vivo and in vitro whether the compound might induce vasorelaxation in human blood vessels through the improvement of nitric oxide (NO) bioavailability and a reduction of oxidative stress mediated by endothelial NO synthase (eNOS) function. MNA + treatment (100 mg/m 2 orally) in healthy normocholesterolemic and hypercholesterolemic subjects increased the l-argini…
Does ovarian blood flow distinguish between ovulatory and anovulatory patients with polycystic ovary syndrome?
2003
The purpose of this study was to determine whether parameters of ovarian blood flow distinguish between women with polycystic ovary syndrome (PCOS) who ovulate and those who are anovulatory.This was a prospectively enrolled trial, carried out as a cross-sectional comparison of 12 ovulatory patients with PCOS and 20 matched subjects with classic PCOS and 10 healthy control subjects. Hormonal parameters and ovarian blood flow by color flow Doppler imaging were obtained in the early follicular phase.Characteristic elevations in luteinizing hormone (LH) and androgens were found in both groups with PCOS compared with control groups. Women with anovulatory PCOS had high insulin levels and lower Q…
Pulsatile versus continuous oxytocin infusion for the oxytocin challenge test.
1994
In a prospective study, 140 patients had an oxytocin challenge test with either a continuous or a pulsed infusion (one minute of infusion in every five minutes). Both infusion regimens had similar success rates in terms of uterine contractions (97.1 vs 98.6%). The potency ratio (pulsed versus continuous infusion) was significant at 2.7 (1.27 to 5.2), which means that more uterine activity was induced with each mU of oxytocin with pulsatile than with continuous administration. The total amount of oxytocin required to obtain three good contractions in 10 minutes was about 40% less with pulsed administration than with continuous infusion, but the test took 40 minutes longer with the pulsed tha…
Evaluation of breast tumor blood flow with dynamic first-pass 18F-FDG PET/CT: comparison with angiogenesis markers and prognostic factors
2012
The purpose of this study was to prospectively evaluate the relationship between tumor blood flow and glucose metabolism as evaluated by dynamic first-pass (18)F-FDG PET and by proliferation and endothelial pathologic markers in the setting of newly diagnosed breast cancer.Forty patients were prospectively included. Biopsy samples of each tumor were used to assess the Ki67 index of proliferation and immunostaining for CD34 (a panendothelial cell marker) and CD105 (a proliferation-related endothelial cell marker). All patients underwent (18)F-FDG PET/CT at least 1 wk after sample biopsy and before any treatment. A dynamic 2-min acquisition was performed immediately after intravenous injectio…
Mass Output and Particle Size Distribution of Glucocorticosteroids Emitted from Different Inhalation Devices Depending on Various Inspiratory Paramet…
2002
Efficient inhalation therapy depends on successful delivery of the drug to the lung. The efficacy of drug delivery is not only influenced by the characteristics of the inhalation device, but also by the patient's handling of the device and by the inspiratory maneuver achieved through the device. We analyzed the output characteristics of three different chlorofluorocarbon (CFC)-free breath-actuated inhalers for inhaled glucocorticosteroids (BUD Turbohaler, FP Diskus/Accuhaler and HFA-BDP Autohaler, respectively). Mass output and particle size distribution of drug aerosol delivered by the inhalers were determined depending on different inhalation parameters in vitro using an Andersen cascade …
Heated breathing tubes affect humidity output of circle absorber systems.
1993
Abstract Study Objective: To verify whether the airway climate in circle systems can be improved with heated breathing tubes. Design: Randomized, controlled, prospective clinical study. Setting: Operating theater of the Department of Maxillofacial Surgery. Patients: 26 adult patients undergoing prolonged anesthesia. Interventions: A total of 26 prolonged anesthetics were conducted in adult patients using a minimal fresh gas flow rate (0.6 L/min) and silicon breathing tubes (16 mm internal diameter) containing a heated coil. Group 1 ( n = 10 patients) was the control group; breathing tubes were unheated. In Group 2 ( n = 10 patients), breathing tubes were heated to 30°C. In Group 3 ( n = 6 p…
Autonomic regulation of nasal vessels during changes in body position
1994
The effects of postural changes on nasal airflow and nasal capillary blood flow were investigated in 15 healthy volunteers. Measurements were performed following nasal application of saline solution (control), the alpha-1 receptor antagonist prazosin, the alpha-2 receptor antagonist yohimbine, and after application of both prazosin and yohimbine. Nasal airflow in the control experiments did not significantly differ in the upright (362 +/- 166 ml/s), dorsally recumbent (350 +/- 167 ml/s) and 70 degrees head down position (311 +/- 167 ml/s). Following application of prazosin, nasal airflow was reduced to 223 +/- 121 ml/s in the upright position. Prazosin treatment significantly reduced nasal …