Search results for "Fluometuron"

showing 4 items of 4 documents

Indirect analysis of urea herbicides from environmental water using solid-phase microextraction.

2000

We described here a solid-phase microextraction procedure used to extract six urea pesticides-- chlorsulfuron, fluometuron, isoproturon, linuron, metobromuron and monuron--from environmental samples. Two polydimethylsiloxanes and a polyacrylate fiber (PA) are compared. The extraction time, pH control, addition of NaCl to the water and the influence of organic matter such as humic acid on extraction efficiency were examined to achieve a sensitive method. Determination was carried out by gas chromatography with nitrogen-phosphorus detection. The proposed method requires the extraction of 2 ml of sample (pH 4, 14.3%, w/v, NaCl) for 60 min with the PA fiber. The limits of detection range from 0…

chemistry.chemical_classificationDetection limitChromatographyFluometuronHerbicidesPhenylurea CompoundsOrganic ChemistryReproducibility of ResultsGeneral MedicineSolid-phase microextractionBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundchemistryHumic acidOrganic matterSample preparationSolid phase extractionGas chromatographyWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Fourier transform infrared determination of Fluometuron in pesticide formulations

2003

Abstract A single method has been developed for Fourier transform infrared (FTIR) determination of Fluometuron in pesticide formulations. Samples were ultrasonically shaken with CHCl3 for 5 min and the FTIR spectra of sample extracts and standards were obtained at a nominal resolution of 4 cm−1 from 4000 to 900 cm−1 accumulating 25 scans. Fluometuron determination is based on the measure of peak area from 1342 to 1321 cm−1 corrected using a baseline defined from 1352 to 1294 cm−1. This procedure provided a limit of detection of 6.5 μg g−1, a sensitivity of 0.852 a.u. g mg−1 for a pathlength of 0.11 mm, a relative standard deviation of 1.6% for three analysis of a sample containing 50.4% (w/…

Detection limitChromatographyChloroformFluometuronResolution (mass spectrometry)Analytical chemistryHigh-performance liquid chromatographychemistry.chemical_compoundsymbols.namesakeFourier transformchemistryLinear regressionsymbolsFourier transform infrared spectroscopySpectroscopyVibrational Spectroscopy
researchProduct

Determination of the Herbicide Fluometuron by Photo‐induced Chemiluminescence in a Continuous‐flow Multicommutation Assembly

2007

Abstract This study was dealing with the chemiluminometric determination of the selective herbicide Fluometuron or 1,1‐dimethyl‐3‐(α,α,α‐trifluoro‐m‐tolyl)urea, (C10H11F3N2O) with a molecular weight 232.29 belongs to the phenyl urea herbicides family. The analytical strategy is based on the continuous‐flow manifold, multicommutation and the analyte pre‐treatment, the photo‐degradation. The optimization of chemical (pH, medium, temperature, and organized media) and hydrodynamic parameters (volume of reagents and flow rate) was performed by univariant and multiparametric simplex procedure respectively. Analytical figures of merit and the effect of foreign substances were studied. The method r…

AnalyteChromatographyFluometuronContinuous flowBiochemistry (medical)Clinical BiochemistryBiochemistryAnalytical ChemistryVolumetric flow ratelaw.inventionchemistry.chemical_compoundchemistrylawReagentElectrochemistryUreaAnalytical strategySpectroscopyChemiluminescenceAnalytical Letters
researchProduct

Gas chromatographic behaviour of urea herbicides

2001

Gas chromatographic conditions for determining eight phenylurea (chlortoluron, diuron, fluometuron, isoproturon, linuron, metabenzthiazuron, metobromuron and monuron) and one sulfonylurea (chlorsulfuron) herbicides were assessed. Degradation products of the herbicides formed in the injector were used for identification. Most phenylureas formed their respective carbamic acid methyl esters, metabenzthiazuron formed an aminobenzothiazol and chlorsulfuron formed an aminotriazine plus a phenylsulfonamide. On-column injection of standards using a BP10 capillary column was evaluated to identify the chromatographic behaviour. Detection limits ranged from 0.05 ng for chlorsulfuron to 3 ng for monuro…

Detection limitFluometuronChromatographymedicine.drug_classOrganic ChemistryClinical BiochemistryBiochemistrySulfonylureaAnalytical Chemistrychemistry.chemical_compoundElectron capture detectorCarbamic acidchemistryChlortoluronmedicineGas chromatographySolid phase extraction
researchProduct