Search results for "Fluorescence"
showing 10 items of 2463 documents
Non-chromatographic speciation of toxic arsenic in vegetables by hydride generation-atomic fluorescence spectrometry after ultrasound-assisted extrac…
2007
A non-chromatographic, sensitive and simple analytical method has been developed for the determination of toxic arsenic species in vegetable samples by hydride generation-atomic fluorescence spectrometry (HG-AFS). As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) were determined by hydride generation-atomic fluorescence spectrometry using a series of proportional equations. The method is based on a single extraction of the arsenic species considered from vegetables through sonication at room temperature with H(3)PO(4) 1 mol L(-1) in the presence of 0.1% (w/v) Triton XT-114 and washing of the solid phase with 0.1% (w/v) EDTA, followed by direct measurement of the co…
Determination of arsenic and antimony in milk by hydride generation atomic fluorescence spectrometry
2002
Abstract A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow m…
Application of ACC method to synchronous luminiscence: determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages.
2001
A new method based on the Q parameter, that permits the determination of the C(compound A)/C(compound B) ratio without preparing calibration graphs of the two compounds, is proposed. This method has been applied to signals obtained by synchronous luminiscence. Simultaneous determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages using synchronous fluorescence has been carried out. To isolate the compounds from samples, liquid extraction with n-hexane as the organic phase was employed. The presence of interferences was tested using the apparent content curves (ACC) method and the C(alpha-tocopherol)/C(alpha-tocopheryl acetate) ratio was calculated using the Q parameter. Th…
Changes in yield ofin-vivo fluorescence of chlorophyll a as a tool for selective herbicide monitoring
1993
Triazines and derivatives of phenylurea, which are often found in outdoor water samples, induce specific changes in the yield of thein-vivo chlorophyll α-fluorescence of PSII. These changes are correlated quantitatively with the concentration of the herbicides and can therefore be used to set-up a low-price monitor system. In order to detect selectively the herbicide-sensitive part of the fluorescence emission a pulse amplitude modulated fluorimeter was used. The bioassay system was optimised with respect to test organism, growing and measuring conditions. The relationship between fluorescence yield and herbicide concentrations were experimentally determined for the triazines atrazine and s…
Enhanced flow-injection–chemiluminometric determination of sulphonamides by on-line photochemical reaction
2003
Abstract The viability of the tandem photochemical reaction-chemiluminescence detection has been studied for an heterogeneous group of sulphonamides (sulphamethoxazole, sulphadiazine, sulphamerazine, sulphamethoxypyridazine, sulphacetamide, sulphadimidine, sulphanilamide, sulphathiazole and sulphaguanidine) using sulphamethoxazole (whose chemiluminescent behaviour has not been previously reported) as a test substance. The ‘on-line’ photochemical-reaction of sulphonamides provides an enhancing influence on the chemiluminometric response of the drugs during their oxidation by potassium permanganate in sulphuric acid medium (sulphamethoxazole, sulphacetamide, sulphadimidine and sulphanilamide …
Hydride generation atomic fluorescence spectrometric determination of ultratraces of selenium and tellurium in cow milk
2003
Abstract A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.
Identification of lipid binders in old oil paintings by separation of 4-bromomethyl-7-methoxycoumarin derivatives of fatty acids by liquid chromatogr…
2005
A HPLC-fluorescence method for identification of drying oils from binding media or protective film used in pictorial works of art prior to conservation or restoration is proposed. Fluorescence derivatization of fatty acids released by hydrolysis of structural drying oils is studied. The derivatization reagent was 4-(bromomethyl)-7-methoxycoumarin with 18-crown-6 as catalyst. Mobile phase was programmed from methanol-water (90:10 v/v) to methanol-water (100:0 v/v) in 25 min. The excitation and emission wavelengths were 325 and 395 nm, respectively. Under these chromatographic conditions, coumarin derivatives of myristic, palmitic, oleic and stearic acids were satisfactorily resolved. The met…
Determination of type A trichothecenes by high-performance liquid chromatography with coumarin-3-carbonyl chloride derivatisation and fluorescence de…
2000
A method for the analysis of type A trichothecenes T-2 toxin, HT-2 toxin, neosolaniol and diacetoxyscirpenol by high-performance liquid chromatography with fluorescence detection using coumarin-3-carbonyl chloride has been developed. Different parameters concerning the analytical procedure such as stability of both the reagent and derivatised analytes, time and temperature of the derivatisation reaction, were studied and optimised. Three different clean-up procedures (solid-phase extraction with silica gel or C-18 cartridges, and liquid-liquid partition between toluene and dihydrogen phosphate buffer) were tested in order to remove the excess reagent peaks. The last procedure gave the best …
Determination of mercury in dry-fish samples by microwave digestion and flow injection analysis system cold vapor atomic absorption spectrometry
1997
Abstract Flow injection analysis system cold vapor atomic absorption spectrometry (FIAS-CV-AAS) preceded by a wet digestion in a microwave oven, as a method for measuring mercury in fish was studied. The digestion process and conditions of the FIAS (carrier concentration: HCl 3% v v ; reducing agent: SnCl2 2% w v : filling and injection times: 8 and 25 min, respectively; and sample volumes) were optimized. The analytical parameters of the proposed method (detection limit = 7.7 ng/g; precision intraassay = 6.7%; interassay = 14.0%) demonstrates its adequacy and are similar to the ones (detection limit = 19.4 ng/g; precision intraassay = 11.2%; interassay = 15.9%) obtained using a conventiona…
Multicommutation hydride generation atomic fluorescence determination of inorganic tellurium species in milk
2005
Abstract A multicommutated flow system has been developed for hydride generation, atomic fluorescence (HG-AFS) determination of tellurate (Te VI ) and tellurite (Te IV ) in milk samples. After a batch leaching of Te by sonication at room temperature for 10 min with aqua regia, sample slurries in acidic medium were merged with sodium borohydride and HCl to obtain data on Te IV . Another portion of the acidic slurry was mixed with KBr and passed through a reaction coil introduced inside a microwave oven to reduce quantitatively Te VI to Te IV which was analyzed by HG-AFS. The detection limit was 0.57 ng g −1 in the original samples. The linear range obtained was till 4 ng ml −1 and the averag…