Search results for "Fluoroscopy"
showing 10 items of 54 documents
Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry
2016
The new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) proposes reducing the limit of equivalent dose to the eye lens. For this reason, it is necessary to make estimates about received equivalent dose to the eye lens of medical staff. This study provides an alternative to dosimetry of the eye lens and hands, using dosimeters nanoDots based on optically stimulated luminescence (OSL) technology in wrist surgery procedure carried out with fluoroscopy.
Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing.
1998
Abstract During 41 procedures of intramedullary nailing of femoral and tibial fractures, the primary surgeon and the first assistant wore ring dosimeters on their dominant index fingers. While the average fluoroscopy time per procedure was 4.6 min, the average dose of radiation to the dominant hand of the primary surgeon was 1.27 mSv and 1.19 mSv to the first assistant. The dose limit for the extremities is 500 mSv per year, as recommended by the International Commission on Radiological Protection. Extrapolation of the mean dose of the primary surgeon and first assistent per procedure of 1.23 mSv leads to the result that the recommended dose limit of 500 mSv would only be exceeded if more t…
Ultrasonography utilization in forearm fractures at the emergency department
2019
Fully robotic Ivor–Lewis esophagectomy (RAMIE4) for esophageal cancer after emergency surgery and ligation of the gastroduodenal artery
2018
We report a case of a 69-year-old patient with esophageal cancer and severe upper gastrointestinal bleeding during neoadjuvant radiochemotherapy who required mass transfusion followed by complex emergency procedures. Despite endoscopic stenting, the bleeding recurred, and thus emergency open surgery was required. Gastric wedge resection of the minor curvature necessitated by perforation caused by the endoscopic stent maneuver and duodenotomy with ligation of the gastroduodenal artery, as the cause of persistent intraluminal bleeding, were performed. The already prepared gastric conduit during the emergency operation did not become ischemic, even though the gastroduodenal artery, left gastr…
Jugular pacing lead extraction with laser sheath: a case report.
2010
Over the past 20 years, the number of patients with pacemakers (PM) or implantable cardioverter defibrillators has risen markedly; consequently, an increasing number of lead-removal procedures have become necessary. A 64-year-old woman presenting with an infected device pocket and positive bacterial cultures ( Staphylococcus aureus ) was admitted to our department for lead removal; in 1991, she underwent VVI PM implantation for atrioventricular II degree Mobitz 1 block, and a unipolar lead was introduced via the left jugular vein. The procedure was performed in our Electrophysiology Lab with a cardiac surgeon on standby, using an excimer laser system emitting the energy at the tip of a flex…
Die direkte perkutane radiologische Jejunostomie (PRJ) und Duodenostomie: eine retrospektive Auswertung
2005
Purpose: To present our experience with direct percutaneous radiologic duodenostomy and jejunostomy (PRJ) for alimentation. Materials and Methods: A retrospective study identified 24 patients who had undergone percutaneous jejunostomy or duodenostomy guided by CT and fluoroscopy over a period of 9 years. Whenever possible, the jejunum was inflated with a 5 French diagnostic catheter and jejunopexy was performed using Cope anchors (T-fasteners). A 12 to 14 French locking pigtail drain was inserted for alimentation. In 8 patients, percutaneous direct jejunostomy was performed using only fluoroscopy. In 9 patients, both CT and fluoroscopy were used to guide the jejunostomy. In all 7 patients w…
Radiation exposure in vascular angiographic procedures.
2012
Abstract Purpose To evaluate dose reduction in vascular angiographic procedures by using fluoroscopy capture instead of digital subtraction angiography frames for documentation. Materials and Methods A total of 764 consecutive vascular interventional procedures performed over a period of 1 year were retrospectively analyzed with respect to the fluoroscopy time and the resulting dose–area product (DAP), the DAP of the radiographic frames, and the overall DAP. Results A total of 70% of the total DAP was a result of the acquisition of radiographic frames, leaving only 30% being applied by fluoroscopy. Conclusions Fluoroscopy capture should be used for documentation whenever possible. A registr…
Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens—results of the EURALO…
2018
International audience; This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to dete…
Fluoroscopy-guided Hepaticoneojejunostomy in Recurrent Anastomotic Stricture after Repeated Surgical Hepaticojejunostomy
2013
Comparative ergonomic workflow and user experience analysis of MRI versus fluoroscopy-guided vascular interventions: an iliac angioplasty exemplar ca…
2014
A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant…