Search results for "Foreign"
showing 10 items of 915 documents
Endophthalmitis following penetrating eye injuries
1997
Postinjury endophthalmitis is the eye infection with the worst prognosis. A retrospective 9-year study was made of penetrating eye injuries, with an analysis of the incidence of infection and its relation to the type of wound and the presence of intraocular foreign bodies. There were 403 cases of penetrating eye injury; of these, 233 affected the cornea and 170 involved the posterior pole. Intraocular foreign bodies were present in 40 cases. Endophthalmitis developed in 4.2% of cases (17/403), and was more common in patients with posterior pole involvement (7%) than in purely corneal trauma (2.1%) (p = 0.03, Chi-square). Infection was in turn more frequent in the presence of intraocular for…
Treatment of Idiopathic Varicoceles by Transfemoral Testicular Vein Occlusion
1981
Percutaneous transfemoral occlusion of the testicular vein is a new alternative in the treatment of idiopathic varicocele. Embolization with the Gianturco coil was done on 27 patients. The occlusion was performed immediately after diagnostic phlebography. The results of followup for 1 year are available for 18 patients. In 1 patient the coil had to be removed because of persistent pain, although cause and effect could not be proved. Two patients had a recurrence. The urographic findings were normal 1 year after embolization. No dislocation of the foreign body was observed. Two patients reported that their wives were pregnant.
Retrospective analysis of management of ingested foreign bodies and food impactions in emergency endoscopic setting in adults.
2016
Background: Ingestion of foreign bodies and food impaction represent the second most common endoscopic emergency after bleeding. The aim of this paper is to report the management and the outcomes in 67 patients admitted for suspected ingestion of foreign body between December 2012 and December 2014. Methods: This retrospective study was conducted at Palermo University Hospitals, Italy, over a 2-year period. We reviewed patients’ database (age, sex, type of foreign body and its anatomical location, treatments, and outcomes as complications, success rates, and mortalities). Results: Foreign bodies were found in all of our 67 patients. Almost all were found in the stomach and lower esophagus (…
Impact of Different Texture of Polypropylene Mesh on the Inflammatory Response
2008
Over the past decade, hernia surgery has undergone a considerable transformation with the use of prosthetic materials. The most used polypropylene meshes induce a rapid acute inflammatory response followed by chronic foreign body reaction. Many factors influence this response such as density, size, physical characteristics, different texture and porosity of each biomaterial. The aim of this study is to assess whether the implant of monofilament or multifilament meshes, in the inguinal hernioplasty, determine a different inflammatory response. Thirty-two male patients were included in the study and were randomly divided into two groups. In the first group (MO) inguinal hernioplasty was perf…
Tension-free hernia repair is associated with an increase in inflammatory response markers against the mesh.
2000
Abstract Background: The purpose of this study was to evaluate the involvement of inflammatory mediators in patients undergoing Lichtenstein tension-free hernioplasty (LH) using polypropylene prosthetic materials or conventional Bassini hernia repair (BH). Methods: Thirty patients male with unilateral inguinal hernia without complications or recurrence were included in this study. Randomly, patients underwent LH or BH. Peripheral venous bloods samples were collected 24 hours prior to surgery and then 6, 24, 48 and 168 hours postoperatively. Results: We present evidences that LH patients showed a higher increased serum level of fibrinogen, C-reactive protein, alpha-1-antitrypsin, and interle…
Impact of the line of sight on toric phakic intraocular lenses for hyperopia
2003
We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.
Complications of Poly Implant Prothèse breast implants: the current discussion
2013
Against the background of the current discussion about Poly Implant Prothèse (PIP, Seyne-sur-mer, France) breast implants, we want to present a case demonstrating the complications such as implant rupture, silicone dissemination and level III silicone lymphadenopathy. A 29-year-old woman with cosmetic breast augmentation with PIP implants 5 years previously showed a sensitive swelling in her right axilla and neck region. All tests to detect an infectious or lymphomatous lymphadenopathy were negative. After ultrasound and MRI, rupture of the right implant was assumed and multiple pathologically enlarged lymph nodes up to supraclavicular region were shown. An excision biopsy of one axillary l…
A swallowed toothbrush
2001
A 27-year-old woman came to the emergency department in April, 1999, after swallowing a toothbrush while cleaning her teeth 1 hour previously. She attributed the accident to clumsiness which made her slip on the wet bathroom floor, thereby forcing the toothbrush deep into her throat She reported no other illnesses. She had no pain, dysphagia, or dyspnoea. On examination she had a normal weight (body mass index of 22 kg/m). Her oropharnyx had no signs of injury and the rest of the physical examination was normal. A chest radiograph showed a toothbrush projecting towards the distal oesophagus with the head pointing to the oropharynx (figure), a finding which was not compatible with the report…
Virtopsy and Living Individuals Evaluation Using Computed Tomography in Forensic Diagnostic Imaging
2019
The applications of forensic radiology involve both Virtopsy both studies on living people - to demonstrate bone age, search for foreign bodies, such as voluntary injection of drug ovules or surgical sponges accidentally forgotten, to assess gunshot wounds, to evaluate injuries by road accidents, and cases of violence or abuse (both in adults and in children). Computed tomography is the most used imaging tool used in forensic pathology and its indications are mainly focused on cases of unnatural deaths or when a crime is suspected. It is preferred over the standard autopsy in selected cases, such as in putrefied, carbonized or badly damaged bodies; or as a preliminary evaluation in mass dis…
Hysteroscopic removal of a gauze inadvertently retained in uterus for two years following caesarean section
2021
Despite the worldwide accomplishment of manual counting procedures of surgical textiles and instruments, cases of retained (forgotten) surgical items (RSIs) still occur. Gauzes are the most frequently RSIs, accounting for 90% of the cases because they are widely used. Approximately half of the cases occur in the context of general surgery procedures, fol- lowed by gynaecological – obstetrics surgery. The time inter- val between initial surgery, diagnosis and removal of the gauze is clinically relevant, as the morbidity and mortality are reduced if the foreign body is removed immediately after the offending operation. We report on a successful hysteroscopic identification and removal of a ga…