Search results for "Fracture"

showing 10 items of 873 documents

A Cohesive-frictional interface model subjected to mixed complex loading paths

2017

The paper presents a cohesive-frictional interface model based on surface damage mechanics. The proposed model is developed under the assumption that the fracture energies in mode I and in mode II are different values, as shown by several experimental evidences. At difference with the most spread available interface models, only one isotropic interface internalvariable is adopted for the constitutive model. The interface constitutive model is developed in a Thermodynamic consistent framework with an Helmholtz free energy potential and the fulfillment of the thermodynamic principles is obtained enforcing the Clausius-Duhem inequality. The damage/friction activation functions and dissipative …

Delamination Fracture Mixed ModeInterface model FrictionSettore ICAR/08 - Scienza Delle CostruzioniDelamination Fracture Mixed Mode; Interface model Friction
researchProduct

Customised products for orbital wall reconstruction: a systematic review

2021

Abstract The purpose of this systematic review was to critically analyze the recent literature to present the state of the art in customized reconstruction of orbital fractures. Three electronic databases and manual search approaches were used to identify relevant articles. Only studies with a controlled clinical study design were included. Primary outcome was defined as the status of recovery (complete/partial functional and esthetic disturbances). The benefit of intra-surgical navigation should be described. Secondary outcome was defined as the time of surgery, post-surgical events and hospitalization. A total of eight studies out of 552 records identified met the inclusion criteria. Post…

Dental ImplantsTitaniumOrbital wallNavigated surgerymedicine.medical_specialtybusiness.industryClinical study designPlastic Surgery ProceduresSurgical MeshPrimary outcomeSecondary outcomeSurgery Computer-AssistedOtorhinolaryngologyHumansMedicineSurgeryMedical physicsOral SurgerybusinessOrbitOrbital FracturesBritish Journal of Oral and Maxillofacial Surgery
researchProduct

Endosseous dental implant fractures an analysis of 21 cases

2008

Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic rehabilitation involved, the number of abutments and pontics, the presence or absence of distal extensions or cantilevers, and loading time to fracture. Implant fracture was more common in males than in females (15:4), and the mean patient age was 56.9 years. Most cases (n = 19) corresponded to implant-supported fixed prostheses - 16 with cantilevers of different lengths ? while only two fractured implants were supporting overdentures instead…

Dental RestorationDental prosthesisRestauració dentalUNESCO::CIENCIAS MÉDICASImplants dentals intraossis:CIENCIAS MÉDICAS [UNESCO]Pròtesis dentalsFracturesEndosseous dental implants
researchProduct

Mechanical resistance of zirconium implant abutments: A review of the literature

2010

The increase of aesthetic demands, together with the successful outcome of current implants, has renewed interest in the search for new materials with enough mechanical properties and better aesthetic qualities than the materials customarily used in implanto-prosthetic rehabilitation. Among these materials, zirconium has been used in different types of implants, including prosthetic abutments. The aim of the present review is to analyse current scientific evidence supporting the use of this material for the above mentioned purposes. We carried out the review of the literature published in the last ten years (2000 through 2010) of in vitro trials of dynamic and static loading of zirconium ab…

Dental Stress AnalysisFracture strengthAbutmentNew materialschemistry.chemical_elementDentistryDental AbutmentsDental MaterialsDental AbutmentsMaterials TestingMedicineCyclic loadingHumansZirconium abutmentGeneral DentistryStatic loadingZirconiumbusiness.industryMechanical resistance:CIENCIAS MÉDICAS [UNESCO]Zirconium implant abutmentOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASFracture resistanceSurgeryResearch-ArticleCyclic loadingImplantZirconiumOral Surgerybusiness
researchProduct

Influence of prefabricated post material on restored teeth: fracture strength and stress distribution.

2006

This work studied how prefabricated intraradicular post material affects the mechanical performance of restored teeth. The effect of using two different materials (glass fiber and stainless steel) with significantly different elastic moduli was studied.A combined theoretical and experimental method was used: first, an experimental fracture strength test was performed on 60 extracted human maxillary central incisors. The teeth were decoronated, treated endodontically and restored, 30 with glass fiber posts and 30 with stainless steel posts. The data were recorded and the results compared using an ANOVA test. Then, the finite element technique was used to develop a model of the restored tooth…

Dental Stress AnalysisMaterials scienceFinite Element AnalysisDentistryMaterials testingModels BiologicalStress (mechanics)Dental MaterialsTooth Fracturesstomatognathic systemFlexural strengthMaterials TestingDentinmedicineHumansComputer SimulationGeneral DentistryElastic modulusTooth Nonvitalbusiness.industryStress distributionElasticity (physics)Stainless SteelElasticityRoot Canal Therapymedicine.anatomical_structureDental Prosthesis DesignGlassStress MechanicalbusinessToothDental AlloysPost and Core TechniqueOperative dentistry
researchProduct

Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses

2017

The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…

Dental Stress AnalysisMaterials scienceGlass ionomer cementDentistryDental Abutments02 engineering and technologyBendingVeneering ceramicDental Materials03 medical and health sciences0302 clinical medicineMaterials TestingCubic zirconiaDental Restoration FailureGeneral Dentistrybusiness.industryFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyDental VeneersGlass Ionomer CementsCeramics and CompositesFracture (geology)Computer-Aided DesignDenture Partial FixedZirconium0210 nano-technologybusinessDental Materials Journal
researchProduct

Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…

2018

PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…

Dental Stress AnalysisMaterials scienceMetal Ceramic AlloysDental Abutments02 engineering and technologyCrossheadDental MaterialsRandom Allocation03 medical and health sciences0302 clinical medicineMaterials TestingFixed partial denturesCubic zirconiaDental Restoration FailureComposite materialGeneral DentistryUniversal testing machineFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyMetal ceramicDental VeneersFracture (geology)Computer-Aided DesignDenture Partial FixedStress MechanicalZirconium0210 nano-technologyJournal of Prosthodontics
researchProduct

Premolars restored with posts of different materials: fatigue analysis

2011

Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentGlass fiberInfluence of post materialMaterials testingCrown (dentistry)Bite ForceDental MaterialsTooth FracturesFlexural strengthMaterials TestingmedicineHumansImplant denturesBicuspidComposite materialGeneral DentistryFEAFatigueTooth NonvitalCrownsImplants dentalsRestored teethStress distributionStainless SteelFinite element methodDental Prosthesis DesignDental Stress AnalysisCeramics and CompositesBiomechanical modelGlassDental materials--FatiguePrefabricated intraradicular postsMaterials dentals--FatigaDental AlloysPost and Core Technique
researchProduct

Fracture resistance after implantoplasty in three implant-abutment connection designs

2020

Background To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results The mean wall thickness reductions varied between 106.46 and 153.75 µm. The me…

Dental Stress AnalysisTitanium implantMaterials scienceCirurgia dentalchemistry.chemical_elementDental Abutments03 medical and health sciences0302 clinical medicineFlexural strengthDental AbutmentsMaterials TestingGeneral DentistryEndosseous dental implantsDental ImplantsTitaniumOrthodonticsCrownsResearchConnection (principal bundle)030206 dentistry:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryDental surgeryUNESCO::CIENCIAS MÉDICASFracture (geology)SurgeryImplants dentals intraossisImplantImplantologyImplant abutmentTitanium
researchProduct

Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.

2009

Summary  Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…

Dental Stress Analysisinfluence of post-materialMaterials sciencemedicine.medical_treatmentGlass fiberFinite Element AnalysisDentistryCrown (dentistry)Dental Materialsstomatognathic systemFlexural strengthstress distributionMaterials TestingmedicineMaxillaHumansMaxillary central incisorDental Restoration PermanentGeneral Dentistryinfluence of post-diameterbusiness.industrybiomechanical performanceStress distributionIncisorstomatognathic diseasesDental Prosthesis DesignFracture (geology)pre-fabricated intra-radicular postsinfluence of crownFinite element techniqueGlassbusinessPost and Core TechniqueJournal of oral rehabilitation
researchProduct