Search results for "Fracture"
showing 10 items of 873 documents
Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.
2007
Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs.Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0…
The assessment of skeletal status in young patients with Turner syndrome by 2 densitometric techniques: Phalangeal quantitative ultrasound and dual e…
2018
Background. Studies using dual energy X-ray absorptiometry (DXA) demonstrate a reduction in bone mineral density (BMD) in children and adolescents with Turner syndrome (TS). However, these studies do not take into account changes in bone size, which influence BMD in the case of short-statured patients. Phalangeal quantitative ultrasound (phQUS) measurements have shown an ability to reveal changes due to skeletal growth, aging, and bone and mineral disorders. There is limited data on bone mineral status in girls with TS assessed by 2 different techniques, i.e., DXA and phQUS. Objectives. The aim of this study was to investigate the potential negative impact of TS on bone status and to assess…
Nonunion and malunion in proximal humerus fractures
2020
Proximal humerus fractures are common injuries and the development of nonunion or malunion is infrequent. However, these complications can occur with both operative and non-operative treatment of the fracture. A complete evaluation of these patients must include an investigation of the original fracture, bone and soft tissue quality as well as an extensive radiological study with X-Ray, CT and MRI. Asymptomatic and low demanding patients can benefit from conservative treatment, otherwise surgery is necessary. Multiple treatment options exist with no consensus upon the gold standard. The management of these complications is case-specific and needs extensive pre-operative planning. Arthroscop…
Surgery for fracture of the calcaneus. 5 (2-8) year follow-up of 20 cases.
1993
20 displaced intraarticular fractures of the calcaneus were treated by open reduction and internal fixation. Results were evaluated according to a standardized protocol. With an average follow-up of 5 (2-8) years, results were excellent or good in 15 cases and fair or poor in 5 cases. An accurate radiographic study and CT scanning are essential for understanding these fractures. We feel that restoring calcaneal shape as anatomic as possible, getting an appropriate reduction of the posterior joint surface by a surgical procedure with early mobilization, and delayed weight bearing would be a good option in treatment of these fractures.
Transverse fracture-dislocation of the sacrum: a diagnostic pitfall and a surgical challenge.
2002
Transverse fracture-dislocations of the sacrum are rare. Associated lesions of the lumbosacral spine as well as neurological injuries are common. Conventional radiographs of the pelvis often fail to clearly visualize the fracture. Delayed diagnosis increases the risk of progressive neurological disfunction. True lateral sacral views and CT-scans with 3-dimensional reconstructions are very helpful in establishing the full extent of the injury. These examinations should be considered in all patients with a history of high energy trauma and clinical signs indicating lumbosacral injury, such as severe low back pain and neurological disturbances of the lower extremities. The management of transv…
The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
2013
Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…
Clinical performance of a highly portable, scanning calcaneal ultrasonometer.
2001
The aim of this study was to establish a normative database, assess precision, and evaluate the ability to identify women with low bone mass and to discriminate women with fracture from those without for a highly portable, scanning calcaneal ultrasonometer: the QUS-2. Fourteen hundred and one Caucasian women were recruited for the study. Among them were 794 healthy women 25–84 years of age evenly distributed per 10-year period to establish a normative database. Of these, 171 aged 25–34 years were defined as the young normal group for the purpose of T-score determination. Precision was assessed within 1 day (short-term) and over a 16-week period (long-term) in 79 women aged 25–84 years. Five…
Monitoring bone growth using quantitative ultrasound in comparison with DXA and pQCT.
2008
Quantitative ultrasound (QUS) is a safe, inexpensive, and nonradiation method for bone density assessment. QUS correlates with, and predicts fragility fractures comparable to, dual-energy X-ray absorptiometry (DXA)-derived bone mineral density (BMD) in postmenopausal women. However, its validity in monitoring bone growth in children is not well understood. Two hundred and fifty-eight 10-13 yr pubertal girls and 9 37-43 yr adults without diseases or history of medications known to affect bone metabolism were included in the 2-yr prospective study. Calcaneal broadband ultrasound attenuation (cBUA) was assessed using QUS-2 (Quidel, Santa Clara, CA), speed of sound of tibial shaft (tSOS) using …
Estimation of structural and geometrical properties of cortical bone by computerized tomography in 78-year-old women
2009
The structural and geometrical properties of the tibia shaft were investigated at two sections by means of computerized tomography (CT) in 78-year-old women with high (n = 19) and low (n = 17) calcaneal bone mineral density (BMD, g/cm3) previously measured by 125I-photon absorption. The high BMD group had a 20-21% higher tibial BMD and 9-12% higher bone cross-sectional area than was observed in the low BMD group. The distribution of bone mass indicated that the low BMD group had lost bone mainly from the endosteal surface, especially in the anterior part of the tibia. However, both groups had a similar basic pattern of mass distribution at the measured sections. The high BMD group had highe…
In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.
2019
Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …