Search results for "Frequency domain"

showing 10 items of 141 documents

Causal and Non-Causal Frequency Domain Assessment of Spontaneous Baroreflex Sensitivity after Myocardial Infarction

2020

Acute myocardial infarction (AMI) is thought to alter the baroreflex control of arterial pressure. We tested this hypothesis investigating the changes of the cardiovascular response after AMI in comparison with young and old healthy controls studied at rest and during head-up tilt, using causal and non-causal frequency domain measures of the baroreflex sensitivity. Our results indicate: (i) the importance of using a causal approach that takes into account not only feedback but also feedforward effects in the study of interactions between the heart period and the arterial pressure; (ii) the compromised capacity of baroreceptors to control SAP fluctuations in post-AMI patients, both at rest a…

electrocardiography (ECG)medicine.medical_specialtyBaroreceptorGain measurementbusiness.industrymusculoskeletal neural and ocular physiologyPostural stresssystolic arterial pressure (SAP)Baroreflexmedicine.diseaseAcute myocardial infarction (AMI)Blood pressurebaroreflex sensitivity (BRS)Frequency domainInternal medicineSettore ING-INF/06 - Bioingegneria Elettronica E InformaticamedicineCardiologycardiovascular diseasesMyocardial infarctionSensitivity (control systems)business
researchProduct

Multipactor radiation analysis within a waveguide region based on a frequency-domain representation of the dynamics of charged particles

2009

[EN] A technique for the accurate computation of the electromagnetic fields radiated by a charged particle moving within a parallel-plate waveguide is presented. Based on a transformation of the time-varying current density of the particle into a time-harmonic current density, this technique allows the evaluation of the radiated electromagnetic fields both in the frequency and time domains, as well as in the near- and far-field regions. For this purpose, several accelerated versions of the parallel-plate Green's function in the frequency domain have been considered. The theory has been successfully applied to the multipactor discharge occurring within a two metal-plates region. The proposed…

electromagnetic fieldsMultipactor effectElectromagnetic fieldcurrent densityImage theoryGreens-FunctionElectrodynamicsAcceleratorelectrodynamicsFinite difference time-domain analysisElectromagnetic radiationmicrowave switchesGreen's function methodslaw.inventionPeriodic StructuresOpticsBreakdownCurrent densitylawTEORIA DE LA SEÑAL Y COMUNICACIONESGreen's functionsFrequency-domain analysisfinite difference time-domain analysisEwald MethodPhysicsTeoría de la Señal y las Comunicaciones2-Dbusiness.industryElectromagnetic fieldsMicrowave switcheswaveguidesParallel plate waveguideCharged particleComputational physicsfrequency-domain analysisTransformation (function)Frequency domainModesDischarge3325 Tecnología de las TelecomunicacionesMultipactor effectbusinessWake-FieldWaveguidesWaveguideCurrent densitySimulationPhysical Review E
researchProduct

Moving RTS/CTS to the frequency domain: an efficient contention scheme for 802.11ax networks

2019

In this paper, we propose a contention mechanism based on the execution of multiple contention rounds in the frequency domain (ReCHo), which is designed to offer high throughput performance and robustness with respect to imperfect carrier sensing. The main idea is using narrow tones as signalling messages for performing channel access contentions and allowing the Access Point (AP) to echo these signals, in order to extend the sensing capabilities to all the stations associated to the AP. In particular, we refer to the emerging IEEE 802.11ax standard, showing how our scheme can boost performance of random access with respect to the current version of IEEE 802.11ax OFDMA Back-Off (OBO), even …

imperfect sensingHidden node problemSettore ING-INF/03 - TelecomunicazioniOrthogonal frequency-division multiplexingComputer sciencebusiness.industryMechanism based020206 networking & telecommunications02 engineering and technologySignallingFrequency-domain signallingRobustness (computer science)020204 information systemsFrequency domainTelecommunications link0202 electrical engineering electronic engineering information engineeringfrequency-domain signalling; IEEE 802.11ax; imperfect sensing; random access contentionrandom access contentionbusinessIEEE 802.11axRandom accessComputer network
researchProduct

Empirical Mode Decomposition on Mismatch Negativity

2008

Empirical mode decomposition (EMD) has been applied in the various disciplines to extract the desired signal. The basic principle is to decompose a time series into intrinsic mode functions (IFMs) and each IFM corresponds to an oscillation phenomenon. A statistical description of the oscillatory activities of the EEG has been well known. It is desired to extract single oscillatory process from the EEG by EMD. Mismatch negativity (MMN) can be automatically elicited by the deviant stimulus in an oddball paradigm, in which physically the deviant stimulus occurs among repetitive and homogeneous stimuli. MMN thus reflects the ability of the brain to detect changes in auditory stimuli. So, the MM…

medicine.diagnostic_testbusiness.industryMismatch negativityPattern recognitionElectroencephalographyHilbert–Huang transformTime–frequency analysisEvent-related potentialFrequency domainmedicineArtificial intelligenceInfomaxbusinessOddball paradigmMathematics
researchProduct

Comparison of frequency domain measures based on spectral decomposition for spontaneous baroreflex sensitivity assessment after Acute Myocardial Infa…

2021

Abstract The objective of this study is to present a new method to assess in the frequency domain the directed interactions between the spontaneous variability of systolic arterial pressure (SAP) and heart period (HP) from their linear model representation, and to apply it for studying the baroreflex control of arterial pressure in healthy physiological states and after acute myocardial infarction (AMI). The method is based on pole decomposition of the model transfer function and on the following evaluation of causal measures of coupling and gain from the poles associated to low frequency (0.04−0.15 Hz) oscillatory components. It is compared with traditional non-causal approaches for the sp…

medicine.medical_specialty0206 medical engineeringBiomedical EngineeringHealth Informatics02 engineering and technologyAcute myocardial infarctionBaroreflexSettore ING-INF/01 - ElettronicaMatrix decomposition03 medical and health sciences0302 clinical medicineInternal medicinemedicineSpectral analysiscardiovascular diseasesMyocardial infarctionSensitivity (control systems)Spectral decompositionbusiness.industryHead-up tiltLinear modelBaroreflexmedicine.disease020601 biomedical engineeringFrequency domainCausalityBlood pressureFrequency domainCardiovascular controlSignal ProcessingSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologybusiness030217 neurology & neurosurgery
researchProduct

Changes in the Spectral Characteristics of Ventricular Fibrillation in Lesions Produced by Radiofrequency Ablation. An Experimental Study

2008

INTRODUCTION AND OBJECTIVES Although electro- physiological databases contain information about changes in the time domain in lesions produced by radiofrequency ablation, very few data on changes in the frequency domain are available. The aim of this study was to investigate changes in the spectral characteristics of ventricular fibrillation in zones with radiofrequency lesions. METHODS Recordings of ventricular fibrillation were obtained in 11 isolated perfused rabbit heart preparations using a multiple epicardial electrode located on the left ventricular free wall. Spectral parameters derived by Fourier analysis before and after the creation of transmural radiofrequency lesions were compa…

medicine.medical_specialtyRadiofrequency ablationHeart VentriclesIn Vitro TechniquesStandard deviationlaw.inventionLesionNuclear magnetic resonancelawInternal medicineAnimalsMedicinebusiness.industrySpectral densityGeneral MedicineDominant frequencymedicine.diseaseMean frequencyFrequency domainVentricular FibrillationVentricular fibrillationCatheter AblationCardiologyRabbitsmedicine.symptombusinessRevista Española de Cardiología (English Edition)
researchProduct

Time and frequency domain analysis of long-term heart rate variability in an experimental model of diet-induced metabolic syndrome

2021

Abstract Background Metabolic syndrome (MetS) is defined as the set of at least three of the following conditions: central obesity, elevation of triglycerides, decreased in high-density lipoproteins, systemic hypertension and glucose intolerance. MetS is linked with a high prevalence of cardiovascular disease, including sudden cardiac death and atrial arrhythmias, which may be a consequence of changes related to the structure, function and autonomic control of the heart. One of the underlying mechanisms responsible could be the alteration of sinus node automaticity. Heart rate variability (HRV) analysis is a useful non-invasive tool for evaluating alterations in neural control of cardiac au…

medicine.medical_specialtybusiness.industryExperimental modelFrequency domainInternal medicineCardiologyMedicineHeart rate variabilityMetabolic syndromeCardiology and Cardiovascular Medicinebusinessmedicine.diseaseTerm (time)European Heart Journal
researchProduct

Wiener-Granger Causality in Network Physiology with Applications to Cardiovascular Control and Neuroscience

2016

Since the operative definition given by C. W. J. Granger of an idea expressed by N. Wiener, the Wiener–Granger causality (WGC) has been one of the most relevant concepts exploited by modern time series analysis. Indeed, in networks formed by multiple components, working according to the notion of segregation and interacting with each other according to the principle of integration, inferring causality has opened a window on the effective connectivity of the network and has linked experimental evidences to functions and mechanisms. This tutorial reviews predictability improvement, information-based and frequency domain methods for inferring WGC among physiological processes from multivariate…

nonlinear dynamicComputer scienceReliability (computer networking)Biomedical signal processingPhysiologyCardiovascular controldynamical systemdirectionalityGranger causalitymultivariate regression modelingtime series analysiPredictabilityTime seriesElectrical and Electronic EngineeringStatistical hypothesis testingbusiness.industryheart rate variabilitytransfer entropypartial directed coherencepredictioncoupling strengthCausalityconditional mutual informationFrequency domainspectral decompositionSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaArtificial intelligencebusinesscomplexityNeuroscience
researchProduct

Rotational effects on the oscillation frequencies of newly born proto-neutron stars

2003

In this paper we study the effects of rotation on the frequencies of the quasi-normal modes of a proto-neutron star (PNS) born in a gravitational collapse during the first minute of life. Our analysis starts a few tenths of seconds after the PNS formation, when the stellar evolution can be described by a sequence of equilibrium configurations. We use the evolutionary models developed by Pons et al. (1999; 2001) that describe how a non rotating star cools down and contracts while neutrino diffusion and thermalization processes dominate the stellar dynamics. For assigned values of the evolution time, we set the star into slow rotation and integrate the equations of stellar perturbations in th…

relativityFOS: Physical sciencesmethods : numericalAstrophysicsAstrophysicsInstabilitystars : oscillationsmethods: numericalstars: neutronstars: rotationstars : rotationStellar dynamicsGravitational collapseAstrophysics::Solar and Stellar AstrophysicsTime domainStellar evolutionPhysicsgravitational waves; methods : numerical; methods: numerical; relativity; stars : neutron; stars : oscillations; stars : rotation; stars: neutron; stars: oscillations; stars: rotationAstrophysics (astro-ph)Astronomy and Astrophysicsstars : neutronNeutron stargravitational wavesSpace and Planetary ScienceFrequency domainstars: oscillationsAstrophysics::Earth and Planetary AstrophysicsNeutrinoMonthly Notices of the Royal Astronomical Society
researchProduct

Exploiting ongoing EEG with multilinear partial least squares during free-listening to music

2016

During real-world experiences, determining the stimulus-relevant brain activity is excitingly attractive and is very challenging, particularly in electroencephalography. Here, spectrograms of ongoing electroencephalogram (EEG) of one participant constructed a third-order tensor with three factors of time, frequency and space; and the stimulus data consisting of acoustical features derived from the naturalistic and continuous music formulated a matrix with two factors of time and the number of features. Thus, the multilinear partial least squares (PLS) conforming to the canonical polyadic (CP) model was performed on the tensor and the matrix for decomposing the ongoing EEG. Consequently, we …

ta113Multilinear mapmedicine.diagnostic_testBrain activity and meditationSpeech recognition02 engineering and technologyElectroencephalographyta3112Matrix decomposition03 medical and health sciences0302 clinical medicinetensor decompositionFrequency domainPartial least squares regression0202 electrical engineering electronic engineering information engineeringmedicineSpectrogramOngoing EEG020201 artificial intelligence & image processingmusicTime domain030217 neurology & neurosurgerymultilinear partial least squaresMathematics
researchProduct