Search results for "Frequency domain"
showing 10 items of 141 documents
Optimal Damping Constant Investigation on a Quarter-Car
2013
This paper shows an investigation on optimal damping constant performed in the frequency domain. The optimal damping constant is meant as that value that minimizes the acceleration of all connected bodies characterizing a two degree of freedom system sketching a quarter car. The connected bodies are sprung and unsprung mass respectively for quarter of chassis and tire, this last keeps the contact with the ground and it is connected with the sprung mass through a shock absorber characterized by spring and fluid damper. Optimal damping constant was determined by imposing analytical conditions on the expression of acceleration of two masses. Afterwards, the variation of acceleration and positi…
Time and frequency analysis of the static balance in young adults with Down syndrome
2010
The main objective of this study is to understand the differences in equilibrium control between normal subjects and those with Down syndrome. A total of 54 subjects participated voluntarily, divided into control group and Down syndrome group. The equilibrium of the subjects was tested under two conditions: bipedal support with eyes open and closed. The signals were analyzed in a time and frequency domain. The statistical parameters selected (i.e., RMS distance, mean velocity, mean frequency and sway area) to analyze the behavior of the center of pressures (CoP) are calculated employing the result of the combination of the time series data in both directions (i.e. resultant distance). In or…
Measuring postural-related changes of spontaneous baroreflex sensitivity after repeated long-duration diving: Frequency domain approaches
2012
Sustained water immersion is thought to modulate orthostatic tolerance to an extent dependent on the duration and repetition over consecutive days of the diving sessions. We tested this hypothesis investigating in ten healthy subjects the potential changes in the cardiovascular response to head-up tilt induced by single and multiple resting air dives. Parametric cross-spectral analysis of spontaneous RR interval and systolic arterial pressure variability was performed in three experimental sessions: before diving (BD), after single 6-hour dive (ASD), and after multiple 6-hour dives (AMD, 5 consecutive days with 18-hour surface interval). From this analysis, baroreflex sensitivity (BRS) was …
Surrogate data approaches to assess the significance of directed coherence: Application to EEG activity propagation
2009
This paper addresses the topic of evaluating the significance of frequency domain measures of causal coupling in multivariate time series through generation of surrogate data. The considered approaches are the traditional Fourier Transform (FT) algorithm and a new causal FT (CFT) algorithm for surrogate data generation. Both algorithms preserve the FT modulus of the original series; differences are in the phase relationships, that are completely destroyed for FT surrogates and imposed after switching off the link over the considered causal direction for CFT surrogates. The ability of the algorithms to assess causality in the frequency domain was tested using the directed coherence as discri…
Testing Frequency-Domain Causality in Multivariate Time Series
2010
We introduce a new hypothesis-testing framework, based on surrogate data generation, to assess in the frequency domain, the concept of causality among multivariate (MV) time series. The approach extends the traditional Fourier transform (FT) method for generating surrogate data in a MV process and adapts it to the specific issue of causality. It generates causal FT (CFT) surrogates with FT modulus taken from the original series, and FT phase taken from a set of series with causal interactions set to zero over the direction of interest and preserved over all other directions. Two different zero-setting procedures, acting on the parameters of a MV autoregressive (MVAR) model fitted on the ori…
Identification of a specific type of PD from acoustic emission frequency spectra
2001
The paper presents an attempt to apply spectral analysis tools in processing acoustic emission (AE) pulses generated by partial discharge (FD). The experimental part of the paper describes spark gaps generating four types of PD and specifies parameters of measured acoustic signals and recalls the system used for measurement and analysis of the frequency spectra. Also, a spectral analysis procedure is presented, and frequency-domain descriptors characterizing AE pulses are defined. The results of the analysis are given both as time plots and amplitude and energy density spectra, related to values of the associated descriptors. The spectral analysis results cover AE pulses generated in system…
Comparative analysis of acoustic emission signals generated by electrical discharges measured by the hydrophone and the wideband contact transducer
2005
The paper presents a comparative analysis of the acoustic emission (AE) pulses and signals generated by PDs. For this purpose the measurements of the acoustic emission signals generated by PDs were taken in the multipoint-plane system using a hydrophone placed directly in the area of discharge generation, and the AE pulses using a piezoelectric contact transducer which was on a side wall of a power transformer tub. Next, time runs and amplitude density spectra were drawn. Also the descriptors describing signals in the frequency domain were determined and the time-frequency analysis was carried out, which determined spectrograms for the energy density spectrum.
Investigating the level of significance of the coherence function in cardiovascular variability analysis
2002
Although the presence of significant coupling between cardiovascular variability series is usually verified according to the threshold value of 0.5 in the coherence function (CF), spectral estimator parameters should also be considered. In this study, the surrogate data technique was introduced to define the level of significance of the CF. The proposed method determined a frequency-dependent threshold over which the hypothesis of zero coherence was rejected. The weighted covariance method and the autoregressive method were used to estimate the CF on simulated series with different degrees of linear coupling and on real cardiovascular data. The threshold was dependent on the type and parame…
Low-complexity AoA and AoD Estimation in the Transformed Spatial Domain for Millimeter Wave MIMO Channels
2021
High-accuracy angle of arrival (AoA) and angle of departure (AoD) estimation is critical for cell search, stable communications and positioning in millimeter wave (mmWave) cellular systems. Moreover, the design of low-complexity AoA/AoD estimation algorithms is also of major importance in the deployment of practical systems to enable a fast and resource-efficient computation of beamforming weights. Parametric mmWave channel estimation allows to describe the channel matrix as a combination of direction-dependent signal paths, exploiting the sparse characteristics of mmWave channels. In this context, a fast Transformed Spatial Domain Channel Estimation (TSDCE) algorithm was recently proposed …
Measuring High-Order Interactions in Rhythmic Processes Through Multivariate Spectral Information Decomposition
2021
Many complex systems in physics, biology and engineering are modeled as dynamical networks and described using multivariate time series analysis. Recent developments have shown that the emergent dynamics of a network system are significantly affected by interactions involving multiple network nodes which cannot be described using pairwise links. While these higher-order interactions can be probed using information-theoretic measures, a rigorous framework to describe them in the frequency domain is still lacking. This work presents an approach for the spectral decomposition of multivariate information measures, capable of identifying higher-order synergistic and redundant interactions betwee…