Study of optical absorbance and MR relaxation of irradiated Fricke Xylenol Orange Gel Dosimeters
2016
Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measurements pe…
Gel dosimeters for medical physics applications
2015
Gel dosimeters for three-dimensional mapping of radiotherapy doses were introduced at Yale University in the mid-1980’s. Soon after, R&D in this field also started in Italy. Early work was done at the Istituto Superiore di Sanità, and at the Universities of Pisa and Milan. Several institutes now collaborate on this topic with support from the Italian Ministry for University and Research (MIUR) through Grant PRIN SNALEM2010 “Development and application of new materials for ionizing radiation dosimetry”. This presentation describes this research, which aims at developing new formulations of hydrogel matrices with improved characteristics of stability, sensitivity and spatial resolution co…
Studio di assorbanza ottica e rilassometria RM in dosimetri a gel di Fricke
2016
I dosimetri a gel di Fricke con xylenol-orange, analizzati otticamente, presentano alcune limitazioni se impiegati per misure di basse dosi (pochi Gy o meno), per irraggiamenti di lunga durata o per individuare procedure di calibrazione che permettano l'utilizzo in radioterapia. Le difficoltà derivano da variazioni nello spettro di assorbanza verosimilmente dovute a variazioni dei legami degli ioni ferrici con lo xylenol-orange. Sono state effettuate misure: i) di assorbanza ottica, anche spettrometrica, per dosimetri irraggiati a diverse dosi e a diversi tempi rispetto all'irraggiamento; ii) di rilassometria RM per valutare le variazioni dovute al solo aumento del numero di ioni ferrici.
PVA gel dosimeters for radiotherapy applications,
2015
Gel dosimeters for three-dimensional mapping of radiotherapy doses were introduced at Yale University in the mid-1980’s. Soon after, research and development in this field also started in Italy. Early work was done at the Istituto Superiore di Sanità, and at the Universities of Pisa and Milan. Several institutes now collaborate on this topic with the goal of developing new formulations of hydrogel matrices with improved characteristics of stability, sensitivity and spatial resolution compared to those of earlier Fricke-gel and polymer-gel systems. Contrary to earlier gels based on natural gelling agents, such as porcine skin gelatin and/or agarose, which suffer from limited batch -to-batch …
Investigation of relaxation times of irradiated Fricke gels by means of nuclear magnetic resonance relaxometry
2016
Fricke gel dosimeters are ideal candidates to provide 3D maps of dose distributions and are particularly useful in the plann ing and verification phase of radiotherapy treatments. One of the most effective experimental techniques to reconstruct dose maps is magnetic resonance imaging (MRI). This measures th e nuclear relaxation times variations induced by irradiation. In this work, we analyzed Fricke gels with and without Xylenol Orange by means of a single side-NMR relaxometer (which is abl e to provide information on both relaxation relaxation times T1 and T2 and is mainly used in the field of diagnostics for Cultural Heritage [1-2] to perform porosimetry meaurements). Our goal was to per…
Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters
2017
Abstract Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measur…
LOW DOSE CHARACTERIZATION OF FRICKE GEL DOSIMETERS BY OPTICAL ABSORBANCE AND MR RELAXATION METHODS
2016
Introduction Fricke gel dosimeters allow measurements of 3D dose distributions and can be an effective tool for dosimetry verifications in radiotherapy. Various authors have reported drawbacks of the gels affecting the accuracy in case of low dose measurements. Purpose This study aims at investigating such drawbacks and at establishing the conditions for an optimal use of the gels. Materials and methods Our dosimeters consist of gels infused with a Fricke ferrous sulphate solution combined with xylenol orange (XO). Two kinds of xylenol orange (XO) and two different gelling agents (gelatin from porcine skin and Agarose) were utilized. Gels are red out by light absorption techniques: images o…
Preliminary magnetic resonance relaxometric analysis of Fricke gel dosimeters produced with polyvinyl alcohol and glutaraldehyde
2017
This work describes the preliminary analysis of Fricke gels dosimeters characterized by a new formulation making use of a matrix of polyvinyl alcohol cross-linked by adding glutaraldehyde and analyzed by means of nuclear magnetic resonance relaxometry. In previous optical studies, these gels have shown promising dosimetric features in terms of photon sensitivity and low diffusion of ferric ions produced after irradiation. In this work, we used a portable nuclear magnetic resonance relaxometer to measure the relaxation times (which are important for dosimetric applications) of these gel materials. For this purpose, we performed a study for optimizing the acquisition parameters with a nuclear…
NUCLEAR MAGNETIC RESONANCE RELAXOMETRY AND IMAGING FOR DOSIMETRY WITH AGAROSE FRICKE GEL
2016
Introduction: Fricke Xylenol Gel (FXG) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. In this kind of gels it can occur that ferrous and ferric ions diffuse in the gel matrix. To preserve the spatial distribution of the dose from diffusion, Fricke gels must be undergoing measurement within a few hours of their irradiation. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained. The oxidation of ferrous ions also causes a reduction of the longitudinal nuclear magnetic relaxation time which can be measured by means of nuclear magnetic resonance (NMR) instrumentation. In this work we performed NMR relaxometry and MR imagin…
Lucy Fricke: Tyttäret
2020
Kirja-arvostelu teoksesta Lucy Fricke: Tyttäret, suom. Anne Kilpi, Kustantamo Huippu, 2020. nonPeerReviewed