Search results for "GLUE"
showing 8 items of 78 documents
Effect of Fibrin Sealant on Seroma Formation Post-Incisional Hernia Repair
2020
Background: Development of seroma after incisional hernia repair is a common complication. Our study aims to compare the outcomes of sublay incisional hernia repairs with or without spray instillation of fibrin glue. Methods: We enrolled fifty patients undergoing incisional hernia repair. In all patients a suction drain was placed in the subcutaneous space. In one group (FG) 4 ml fibrin glue was instilled in the subcutaneous space. In the control group (C) patients did not receive any prevention measure. Wounds fluids were collected on post-operative day 1 (POD) and once daily until drain removal. All patients were followed up by ultrasound on POD 15, 20, 40, 60. Results: Drain fluid produc…
Tightness of duraplasty in rabbits: a comparative study.
2000
OBJECTIVE: The purpose of this study was to test, in rabbits, the tightness of seven dural substitution materials commonly used in neurosurgery, i.e., Lyodura (B. Braun Melsungen AG, Melsungen, Germany), Tutoplast dura (Tutogen Medical, Inc., Parsippany, NJ), Tutoplast fascia lata (Tutogen Medical, Inc.), autologous periosteum, Neuropatch (B. Braun Melsungen AG), Dacron (E.I. du Pont de Nemours and Co., Wilmington, DE), and Ethisorb (Ethicon, Inc., Somerville, NJ). METHODS: Duraplasties were performed with sutures alone or were additionally fixed with fibrin glue. Leakage pressures were assessed by infusion of artificial cerebrospinal fluid, containing sodium fluorescein, into the cisterna …
Natura abhorret a vacuo. Future perspectives of autologous fibrin glue. Is it time for reappraisal?
2017
Arachnoidalzyste der Keilbeinhöhle
1998
BACKGROUND Arachnoid cysts of the paranasal sinus are rare. They have not been described yet in the sphenoid sinus. PATIENT AND METHOD Microscopic-endoscopic endonasal surgery of the sphenoid sinus was performed on a 34-year-old female with a history of chronic headaches and a suspected mucocele of the sphenoid sinus in computed tomography (CT) and magnetic resonance imaging (MRI) studies. An extended arachnoid cyst was found in the enlarged sphenoid sinus, which was obliterated with collagen, fibrin glue, and abdominal fat. RESULTS There were no complications after the operation, and 12 months later the patient is still free of symptoms. CONCLUSION Arachnoidal cysts present in CT and MRI a…
Technical Detail on Nerve Coaptation in Phalloplasty: Use of Fibrin Glue Instead of Sutures.
2019
Die perkutane Harnleiterokklusion
1991
One hundred and nineteen transrenal occlusions of 77 ureters were carried out in 71 patients. Thirty-one ureters were occluded by means of glue and in 21 Gianturco coils were introduced at the same time. Forty-six ureters were occluded by means of disposable silicone-filled latex balloons. Seventeen out of 31 ureters treated with glue (55%) and 32 out of 46 ureters with balloons (70%) were permanently occluded. On 42 occasions, re-occlusions had to be carried out, the average period from the initial occlusion being 2.5 weeks for glue and 19.5 weeks for balloons. In nine out of the 119 ureteric occlusions (7.5%), there were mild complications; these were easily treated and were of no consequ…
Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures.
2015
Background Epidural hematomas, cerebrospinal fluid fistula, and spinal infections are challenging postoperative complications following vertebro-spinal procedures. We report our preliminary results using autologous fibrin sealant as both fibrin glue and a hemostatic during these operations. Methods Prospectively, between January 2013 and March 2015, 68 patients received an autologous fibrin sealant prepared with the Vivostat(®) system applied epidurally to provide hemostasis and to seal the dura. The surgical technique, time to bleeding control, and associated complications were recorded. Results Spinal procedures were performed in 68 patients utilizing autologous fibrin glue/Vivostat(®) to…
Analysis of FBG reflection spectra under uniform and non-uniform transverse loads
2019
Loads applied transversely on the external surface of waveguides change their circular cross-sectional geometry generating birefringence. Due to this effect the reflected spectrum of a Fibre Bragg grating (FBG) undergoes a splitting of the single peak of the Bragg wavelength. In this work, we employed the Transfer Matrix Method (TMM) for x- and y-polarized wave-modes to model the uniform FBG reflection spectra for uniform and non-uniform transverse loads. We also performed experimental measurements for two different transverse load scenarios. The load profiles chosen for these experiments were applied on the FBG sensor through a block of steel and a roll bearing pin. Then, the modelled and …