Search results for "Geant4"

showing 8 items of 18 documents

Alanine/ESR dosimetry for electron Intra-Operative RadioTherapy: output factor measurements and Monte Carlo-GEANT4 simulations for IORT mobile dedica…

2015

Intra-operative radiation therapy (IORT) is a treatment modality where a single high dose of radiation is delivered directly to the tumor bed or to the exposed tumor during the surgical intervention, while avoiding surrounding dose-limiting structures. Mobile electron linear accelerators dedicated to IORT have been manufactured which have promoted a local large diffusion of this radiotherapy modality. For breast irradiation, a single fraction of 21 Gy delivered on the target volume during the surgical procedure is equivalent to the total dosage (60 Gy) usually delivered during 30 external fractionated radiotherapy at 2Gy/fraction. Alternatively, a single dose of 10 Gy can be administered as…

Output FactorsIORTSettore FIS/01 - Fisica SperimentaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiaGEANT4Settore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)IEORTESR
researchProduct

Preliminary assessment of the ATHENA/WFI non-X-ray background

2017

We present a preliminary assessment of the non-X-ray background for the WFI on board ATHENA conducted at IAAT in the context of the collaborative background and radiation damage working group activities. Our main result is that in the baseline configuration originally assumed for the camera the requirement on the level of non-X-ray background could not be met. In light of the results of Geant4 simulations we propose and discuss a possible optimization of the camera design and pinpoint some open issues to be addressed in the next phase of investigation. One of these concerns the possible contribution to the non-X-ray background from soft protons and ions funneled to the focal plane through t…

Physicsbusiness.industryX-ray backgroundGeant4Astronomy and AstrophysicsContext (language use)ATHENA/WFIAstronomy and Astrophysic01 natural sciences010309 opticsOn boardCardinal pointOpticsSettore FIS/05 - Astronomia E AstrofisicaSpace environmentSpace and Planetary ScienceProton scattering0103 physical sciencesSystems engineeringNon-X-ray backgroundbusiness010303 astronomy & astrophysicsSpace environmentExperimental Astronomy
researchProduct

Dosimetria tramite Risonanza Elettronica di Spin (ESR) in RadioTerapia IntraOperatoria (IORT): misure di Output Factors e simulazioni Monte Carlo-GEA…

2016

La RadioTerapia IntraOperatoria (IORT) è una modalità di trattamento in cui una singola dose di radiazioni è impartita direttamente al letto tumorale o al tumore durante l'intervento chirurgico, evitando di colpire i tessuti sani circostanti. La fabbricazione di acceleratori lineari mobili per elettroni dedicati alla IORT ha permesso una grande diffusione di questa tecnica radioterapica. Lo scopo di questo lavoro è il confronto tra la risposta di dosimetri di alanina letti tramite Risonanza Elettronica di Spin (ESR) e di camere a ionizzazione Markus per le misurazioni degli Output Factors (OFs) di fasci di elettroni prodotti da un acceleratore lineare utilizzato per la IORT. Gli OFs dei fas…

Settore FIS/01 - Fisica SperimentaleIORT ESR EPR MC-Geant4 Alanina Dosimetria elettroniSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

New design and simulation of the ion guide for neutron-induced fission products at the IGISOL facility

2023

Measurements of independent fission yield distributions in neutron-induced fission at high neutron energies are important for our fundamental understanding of the fission process, and are also relevant for reactor physics applications. So far, measurements of independent fission yields in proton-induced fission have been performed at the IGISOL facility at the University of Jyväskylä, using the Penning trap as a high resolving-power mass-filter. In order to also facilitate measurements of neutron-induced fission, a dedicated ion guide and a proton-to-neutron converter was developed. However, the first measurement indicates that fewer fission products than expected reach the Penning trap. To…

Subatomär fysikfissioCOMSOLydinreaktiotionitiimulationSubatomic Physicsion guideneutronitNeutron-induced fissionydinfysiikkaGEANT4electric field
researchProduct

Radial electron fluence around ion tracks as a new physical parameter for the detection threshold of PADC using Geant4-DNA toolkit

2018

International audience; The detection threshold of poly(allyl dyglycol carbonate), PADC, for C ions is determined as 55 eV/nm in stopping power, which is significantly higher than that for proton and He ions. The stopping power is not a universal parameter for expressing the detection threshold of PADC. A new physical parameter of Radial Electron Fluence around Ion Tracks, REFIT, is proposed to describe the detection threshold of PADC. It is defined as the number density of electrons passing through the surface of a cylinder of a certain radius that is co-axial with the trajectory. Furthermore, preliminary calculations are presently being performed using the Monte Carlo simulation code of G…

[PHYS]Physics [physics]Detection thresholdRadiationMaterials scienceProtonGeant4-DNAIon trackLatent trackMonte Carlo methodREFIT02 engineering and technologyElectron021001 nanoscience & nanotechnologySecondary electronsPADC030218 nuclear medicine & medical imagingComputational physicsIon03 medical and health sciences0302 clinical medicineStopping power (particle radiation)Impact parameter0210 nano-technologyInstrumentationRadiation Measurements
researchProduct

Characterization of a neutron–beta counting system with beta-delayed neutron emitters

2016

A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known β-delayed neutron emission properties. The setup consists of BELEN-20, a 4π neutron counter with twenty 3He proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for β counting and a selftriggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, β and β-neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on the accura…

beta-delayed neutron emission probabilityAstrophysics::High Energy Astrophysical PhenomenaNuclear TheoryGeant4 simulationsself-triggered digital data acquisition systemNuclear Experimentneutron and beta counters
researchProduct

Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

2011

Purpose: Recently, a new HDR 60 Co brachytherapy source, Flexisource Co-60, has been developed (Nucletron B.V. Veenendaal, The Netherlands). This study aims to obtain dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. Material and methods: Two Monte Carlo radiation transport codes were used: Penelope2008 and GEANT4. The source was centrally-positioned in a 100 cm radius water phantom. Absorbed dose and collisional kerma were obtained using 0.01 cm (close) and 0.1 cm (far) sized voxels to provide high-resolution dosimetry near (far from) the source. Dose rate distributions obtained with the two Monte Carlo codes were compared. Results and Discussi…

business.industryFlexisource Co-60Penelope2008medicine.medical_treatmentBrachytherapyMonte Carlo methodbrachytherapyImaging phantomComputational physicsKermaOncologyAbsorbed doseMedicineDosimetryRadiology Nuclear Medicine and imagingOriginal ArticlebusinessDose rateRadiation treatment planningNuclear medicineTG-43GEANT4Journal of contemporary brachytherapy
researchProduct

Technical note : Simulation of lung counting applications using Geant4

2023

A Geant4 simulation package has been developed to investigate and test detector configurations for lung counting applications. The objective of this study was to measure radiation emitted from the human body and to make a qualitative comparison of the results of the simulation with an experiment. Experimental data were measured from a plastic phantom with a set of lungs containing 241Am activity. For comparison, simulations in which 241Am activity was uniformly distributed inside the lungs of the ICRP adult reference computational phantom were made. The attenuation of photons by the chest wall was simulated and from this photopeak ef-ficiency and photon transmission were calculated as a fun…

lung countingBiophysicsGeant4 simulationGeneral Physics and AstronomyGeneral Medicinegammasäteily114 Physical sciencesLung countingmittausmenetelmätradioaktiiviset aineetvoxel phantomsäteilyannoksetsäteilyfysiikkailmaisimetLow-energy gamma-ray spectralow-energy gamma-ray spectraRadiology Nuclear Medicine and imagingsimulointiVoxel phantomkeuhkot
researchProduct