Search results for "Gel"

showing 10 items of 3561 documents

In Vitro and In Silico Studies of Two 1,4-Naphthoquinones and Their Topical Formulation in Bigels.

2021

Background: 1,4-Naphthoquinones (1,4-NQs) are secondary plant metabolites with numerous biological activities. 1,4-NQs display low water solubility and poor bioavailability. Bigels are a new technology with great potential, which are designated as drug delivery systems. Biphasic bigels consisting of solid and liquid components represent suitable formulations improving diffusion and bioavailability of NQs into the skin. Objective: We evaluated the in silico and in vitro activity of 5,8-dihydroxy-1,4-naphthoquinone (M1) and 2,3-dichloro-5,8-dihydroxy-1,4-naphthoquinone (M2) on elastase and assessed their cytotoxicity towards COLO38 melanoma cells. The 1,4-NQs were loaded into bigels for topi…

ChromatographyElastasePharmaceutical ScienceResazurinHydrogelsPermeationIn vitroBioavailabilitySolventMolecular Docking Simulationchemistry.chemical_compoundDrug Delivery SystemschemistryDrug deliveryCytotoxicityRheologyNaphthoquinonesCurrent drug delivery
researchProduct

Comparative study of Zorbax Bio Series GF 250 and GF 450 and TSK-Gel 3000 SW and SWXL columns in size-exclusion chromatography of proteins.

1988

Abstract A reduction of the mean particle diameter of silica-based packings in the size-exclusion chromatography (SEC) of proteins to about 5 μm generates the expected increase in column plate number over the traditional 10 μm SEC columns, as demonstrated for the Zorbax Bio Series GF 250 and GF 450 and TSK-Gel 3000 SWXL columns. The slightly lower column efficiency of the TSK-Gel 3000 SWXL compared with the GF 250 column is compensated by the fact that the phase ratio of the 3000 SWXL column is higher by a factor of two. Hence both columns show nearly the same peak capacity of about 20–30. When the ionic strength of the eluent was changed by varying the salt concentration, the elution volum…

ChromatographyElutionChemistryOrganic ChemistrySize-exclusion chromatographyAnalytical chemistryProteinsDextransGeneral MedicineSilicon DioxideBiochemistryAnalytical ChemistryMolecular WeightColumn chromatographyIonic strengthPhase ratioParticle diameterChromatography GelPeptidesChromatography High Pressure LiquidJournal of chromatography
researchProduct

An automatic multidimensional chromatography system for purification of human uterine progesterone receptor and induction of polyclonal antibodies.

1986

Abstract This paper reports on the synthesis of Org2058-bonded microparticulate silicas and their use in affinity chromatography as the first step for the purification of human progesterone receptor. The development of microprocessor-controlled instruments allows all the various steps to be performed automatically. The various steps used for the purification of human progesterone receptor were carried out with the FPLC system: (1) affinity chromatography, (2) desalting of eluate on Sephadex G-25, (3) anion-exchange chromatography using a Mono Q column. With this procedure the receptor was purified approx. 10,000-fold within 24 h. The yield of receptor was generally 85–95%. Investigations wi…

ChromatographyElutionSize-exclusion chromatographyUterusFast protein liquid chromatographyBiologyLigandsBiochemistryAntibodiesChromatography AffinitySepharoseEndocrinologyAffinity chromatographySephadexPregnenedionesProgesterone receptorHumansElectrophoresis Polyacrylamide GelFemaleReceptorDesoxycorticosteroneReceptors ProgesteroneChromatography High Pressure LiquidJournal of steroid biochemistry
researchProduct

Filter-based infrared detectors for high temperature size exclusion chromatography analysis of polyolefins: calibration with a small number of standa…

2012

Infrared detection has been shown to be very appropriate for high temperature analysis of polyolefins. After some early reports in which dispersive or single-band filter-based detectors were applied, Fourier transform detectors have been described for this application, in order to improve the method sensitivity. Modern simple filter-based detectors prove, however, comparable sensitivity while providing a number of practical advantages when coupled to chromatographic systems: reduced cell volume, simplified hardware, continuous generation of absorbance chromatograms, as well as simpler data collection and processing. A practical method for calibration, using multiple-band signals obtained wi…

ChromatographyHot TemperatureResolution (mass spectrometry)Spectrophotometry InfraredChemistryOrganic ChemistryDetectorGeneral MedicinePolyenesSignal-To-Noise RatioBiochemistryAnalytical ChemistryAbsorbanceMolecular Weightsymbols.namesakeSignal-to-noise ratioFourier transformFilter (video)CalibrationMultivariate AnalysisCalibrationsymbolsChromatography GelLinear ModelsSensitivity (control systems)Journal of chromatography. A
researchProduct

An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.

2002

A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…

ChromatographyIon exchangeChemistryIon chromatographyAnalytical chemistryProteinsUltrafiltrationFibroblastsMass spectrometryChromatography Ion ExchangeHigh-performance liquid chromatographyOnline SystemsPeptide MappingAnalytical ChemistryCell LineMatrix (chemical analysis)Matrix-assisted laser desorption/ionizationTwo-dimensional chromatographySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationElectrophoresis Polyacrylamide GelChromatography High Pressure LiquidAnalytical chemistry
researchProduct

Sulphonic acid strong cation-exchange restricted access columns in sample cleanup for profiling of endogeneous peptides in multidimensional liquid ch…

2006

Abstract In this work, the pore structural parameters and size exclusion properties of LiChrospher strong cation-exchange and reverse phase restricted access materials (RAM) are analysed. The molecular weight size exclusion limit for polystyrenes was found to be about 17.7 kDa, while for standard proteins, the molecular weight size exclusion limit was higher, at approximately 25 kDa. The average pore diameter on a volume basis calculated from the pore network model changes from 8.5 nm (native LiChrospher) to 8.6 nm (diol derivative) to 8.2 nm (sulphonic acid derivative) to 6.9 nm ( n -octadecyl derivative). Additional characterisations were performed on restricted access materials with nitr…

ChromatographyIon exchangeChemistryOrganic ChemistrySize-exclusion chromatographyAnalytical chemistrySorptionGeneral MedicineBiochemistryAnalytical ChemistryGel permeation chromatographyAdsorptionMicroelectrophoresisSample preparationSolid phase extractionJournal of Chromatography A
researchProduct

New insights on the thermal analysis of low moisture composite foods.

2014

Abstract Low moisture baked products were investigated with a view to characterising the effect of both formulation and humidity on their physical stability. At the end of the baking process, the samples were in the amorphous state as a result of starch gelatinization and sugar melting. Their thermal properties were analyzed with differential scanning calorimetry and their glass transitions were studied. The DSC thermograms were thoroughly studied through a Gaussian deconvolution of the first derivative of their heat flow. This approach evidenced a multiple phase behavior with different glass transitions in composite systems. They were associated with either a polymer-rich phase and/or a pl…

ChromatographyMaterials sciencePolymers and PlasticsMoistureCalorimetry Differential ScanningOrganic ChemistryComposite numberFlourCarbohydratesTemperatureHumidityAmorphous solidStarch gelatinizationDifferential scanning calorimetryChemical engineeringPhase (matter)Materials ChemistryThermal analysisGlass transitionFood AnalysisCarbohydrate polymers
researchProduct

Optimization of Labeling PSMAHBED with Ethanol-Postprocessed 68Ga and Its Quality Control Systems

2017

Radiolabeling of the prostate-specific membrane antigen (PSMA) inhibitor Glu-NH-CO-NH-Lys(Ahx) using the 68Ga chelator HBED-CC (PSMAHBED) allows imaging of prostate cancer lesions because of high expression of PSMA in prostate carcinoma cells and in bone metastases and lymph nodes related to the disease. The aim of this work was to optimize labeling of 68Ga-PSMAHBED using the efficient cation-exchange postprocessing of 68Ga as well as the development of a thin-layer chromatography (TLC)-based quality control system. Methods: Labeling was optimized for online ethanol-postprocessed 68Ga eluate investigating various parameters, such as buffer molarity (0.1-1 M), temperature (25°C-90°C), tracer…

ChromatographyMolar concentrationElutionSilica gelProstate carcinomaClinical routine030218 nuclear medicine & medical imaging03 medical and health scienceschemistry.chemical_compound0302 clinical medicinechemistryQuality control system030220 oncology & carcinogenesisRadiology Nuclear Medicine and imagingMembrane antigenJournal of Nuclear Medicine
researchProduct

Membrane Protein Subunit Fractionation by Means of Inverse Pore Gradient Elution Polyacrylamide Gel Electrophoresis

1996

We report here the preparative scale isolation of the four subunits of the nicotinic acetylcholine receptor (nAChR) applying short inverse pore gradient SDS gels on an elution-PAGE apparatus. The nAChR subunits are of similar molecular weights (alpha, 50.2 kDa; beta, 53.7 kDa; gamma, 56.3 kDa; delta, 57.6 kDa) and isoelectric point (approx 5.5) and share the typical properties of amphiphatic membrane proteins that are difficult to separate by chromatographic procedures. Preparative PAGE, which has proved to be the method of choice for nAChR-subunit fractionation, however, is time-consuming and achieves only moderate resolutions yielding dilute fractions. We present here the fractionation of…

ChromatographyMolecular massProtein ConformationProtein subunitPolyacrylamideBiophysicsMembrane ProteinsCell BiologyFractionationModels TheoreticalReceptors NicotinicTorpedoBiochemistryMolecular Weightchemistry.chemical_compoundMembraneIsoelectric pointchemistryMembrane proteinEvaluation Studies as TopicAnimalsElectrophoresis Polyacrylamide GelIsoelectric PointMolecular BiologyPolyacrylamide gel electrophoresisAnalytical Biochemistry
researchProduct

Molecular topology and chromatographic retention parameters for benzodiazepines

1992

Abstract The relationship between gas-liquid chromatographic (GLC) retention properties and R F values in thin-layer chromatography (TLC) with molecular connectivity indices, m X t , was investigated for a series of benzodiazepines using multiple correlation coefficients, standard errors of estimate, F -Snedecor function values and Student's t -test as the criteria for best equation selection. Regression analyses show that the molecular connectivity model predicts the retention properties in GLC with the polar stationary phase OV-17 at 280°C and the R F values in TLC with the stationary phase silica gel. However, zero- or second-order connectivity indices alone are not sufficient; higher-or…

ChromatographyMolecular modelChemistrySilica gelOrganic ChemistryZero (complex analysis)Analytical chemistryGeneral MedicineFunction (mathematics)BiochemistryThin-layer chromatographyAnalytical Chemistrychemistry.chemical_compoundPolarMultiple correlationGas chromatographyJournal of Chromatography A
researchProduct